My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FLOOD ZONE - 4810 W Sixth St Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Sixth St
>
4810 W Sixth St Unit# 2
>
FLOOD ZONE - 4810 W Sixth St Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:17:06 PM
Creation date
6/6/2025 1:16:45 PM
Metadata
Fields
Template:
Plan
Permit Number
101122162
Full Address
4810 W Sixth St Unit# 2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Page 5 <br /> <br />the new structures could still suffer damage if liquefaction occurs, during a very strong <br />earthquake. <br /> <br />For conservative purposes, a strengthened / stiffened foundation system as <br />recommended in this report should be used for support of the proposed structure. <br /> <br />Slope Stability <br /> <br />The site is a flat area; therefore, slope instability is not a concern for the proposed <br />development. <br /> <br />CONCLUSIONS AND RECOMMENDATIONS <br /> <br />General Conclusions <br /> <br />Construction of the proposed structure at the subject site is considered geotechnically <br />feasible, provided the recommendations outlined in this report are implemented. <br /> <br />Note: The conclusions and recommendations of this report are based on information as <br />interpreted from our limited subsurface investigation. It is not anticipated but they should <br />be revised accordingly if geotechnical conditions to be exposed during site preparation/ <br />grading and construction significantly differ from our findings and interpretations. <br /> <br />In general, a conventional shallow foundation can be used for support of the proposed <br />structure. <br /> <br />The following recommendations are considered minimum and may be superseded by <br />more restrictive requirements of the architect, civil/structural engineer, building codes, or <br />governing agencies. <br /> <br />Geotechnical Impact on Neighboring Properties <br /> <br />Adverse geotechnical impact of the proposed development on the neighboring properties <br />is not anticipated, provided the recommendations outlined in this report are properly <br />implemented. <br /> <br />Site Preparation/Grading <br /> <br />To create a relatively uniform new engineered compacted fill layer for a proposed new <br />structural slab-on-grade area, over-excavation and recompaction of about 3 ft. deep <br />(measured from the existing ground surface) of the existing on-site soils should be <br />performed. The lateral limits of the over-excavation should be minimum equal to depth of <br />removal (3 ft. in this case) beyond the outside perimeter of the proposed new structure. <br /> <br />FLOOD ZONE - 4810 W Sixth <br />St Unit# 25/5/2025
The URL can be used to link to this page
Your browser does not support the video tag.