Laserfiche WebLink
1 <br />2 <br />HOUSE PHOTO <br />VICINITY MAP SCALE: NTS <br />ESPV-0 <br />ESPV-0 <br />SCALE: NTS <br />PROJECT SITE <br />COVER PAGE <br />PROJECT SITE <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />ESPV-0 <br />DATE: 09/26/2024 <br />61 <br />7 <br /> <br /> S <br /> <br />B <br />R <br />O <br />A <br />D <br />W <br />A <br />Y <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />, <br /> <br />U <br />S <br />A <br />ZA <br />B <br />A <br />L <br />E <br />T <br />A <br />, <br /> <br />G <br />R <br />A <br />C <br />I <br />E <br />L <br />A <br />RE <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />PH <br /> <br />N <br />O <br />. <br /> <br />(9 <br />4 <br />9 <br />) <br /> <br />3 <br />0 <br />3 <br />- <br />9 <br />0 <br />9 <br />3 <br />REVDATE DESCRIPTION <br />REVISIONS <br />EM <br />A <br />I <br />L <br /> <br />I <br />D <br />: <br /> <br />z <br />a <br />v <br />a <br />l <br />e <br />t <br />a <br />p <br />3 <br />4 <br />8 <br />@ <br />g <br />m <br />a <br />i <br />l <br />. <br />c <br />o <br />m <br />SUNNOVA ENERGY <br />CORPORATION <br />20 GREENWAY PLAZA, SUITE 475 <br />HOUSTON, TX 77046 <br />P: 281.985.9900 <br />L: 1003498 <br />A08/24/2024 REVISION <br />B09/26/2024 REVISION <br />VICINITY <br /> GPS LOCATION : (33.738783, -117.869531) <br />NEW EQUIPMENT SUMMARY <br />12 CANADIAN SOLAR CS6R-395MS-HL (395W) MODULES <br />12 ENPHASE IQ8PLUS-72-2-US (240V) MICROINVERTERS <br />EXISTING EQUIPMENT SUMMARY <br />16 EXISTING REC SOLAR REC320TP2M (320W) MODULES <br />16 ENPHASE IQ7-60-2-US [240V] MICROINVERTERS <br />PROJECT SITE <br />SHEET INDEX <br />ESPV-0 COVER PAGE <br />ESPV-0A ELECTRICAL NOTES <br />ESPV-1 SITE PLAN <br />ESPV-2 ROOF PLAN & MODULES <br />ESPV-2A STRING LAYOUT & BOM <br />ESPV-3 ATTACHMENT DETAIL <br />ESPV-4 ELECTRICAL LINE DIAGRAM <br />ESPV-4A ELECTRICAL CALCS. <br />ESPV-4B ELECTRICAL SPECS & CALCS. <br />ESPV-5 SIGNAGE <br />ESPV-6+EQUIPMENT SPECIFICATIONS <br />(N) SYSTEM RATING <br />4.74 KWDC <br />4.32 CEC KWAC <br />SCOPE OF WORK: <br />TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE RESIDENCE LOCATED AT <br />617 S BROADWAY, SANTA ANA, CA 92701, USA. THE POWER GENERATED BY THE PV SYSTEM WILL BE <br />INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. <br />THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES. <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA FIRE CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA ENERGY CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />AHJ : SANTA ANA CITY <br />GENERAL NOTES: <br />1. THESE NOTES SET MINIMUM STANDARDS FOR CONSTRUCTION. THE DRAWINGS GOVERN <br />OVER THESE NOTES TO THE EXTENT SHOWN. ALL WORK SHALL CONFIRM TO THE MINIMUM <br />STANDARDS OF THE FOLLOWING: LOCAL BUILDING CODE, LOCAL ELECTRICAL CODE, ANY <br />PORTION OF THE <br />WORK AND THOSE CODES AND STANDARDS LISTED IN THESE DRAWINGS AND IN THE <br />SUBCONTRACTOR AGREEMENT. REFER TO REFERENCE DOCUMENTS LIST. <br />2. COORDINATE THESE DRAWINGS WITH SPECIFICATIONS AND MANUFACTURER'S <br />INSTALLATION AND OPERATION MANUALS AND NOTIFY CONTRACTOR OF ANY DISCREPANCIES <br />PRIOR TO BEGINNING WORK. <br />3. PRIOR TO THE COMMENCEMENT OF ANY WORK, EACH TRADE SHALL VERIFY EXISTING <br />CONDITIONS AND NOTIFY CONTRACTOR OF ANY DISCREPANCIES TO THAT WHICH IS SHOWN IN <br />THESE <br />DRAWINGS, INCLUDING BUT NOT LIMITED TO DIMENSIONS OF THE WORK AREA, STRUCTURE, <br />EXISTING ELECTRICAL SERVICE, CONDUIT PATHS, OBSTRUCTIONS, ACCESSIBILITY ISSUES, AND <br />WORKING CLEARANCES. UNLESS INDICATED AS EXISTING (E), ALL PROPOSED MATERIALS AND <br />EQUIPMENT ARE NEW. <br />4. MAINTAIN CONTINUITY OF ALL EXISTING CIRCUITS OR PORTIONS THEREOF AFFECTED BY <br />NEW WORK. <br />5. ALL ITEMS TO BE REMOVED AND RELOCATED OR REPLACED SHALL BE HANDLED WITH <br />PROPER CARE AND STORED IN A SAFE PLACE TO PREVENT DAMAGE; OR BE REPLACED AT THE <br />SUBCONTRACTOR'S EXPENSE. <br />6. ALL EQUIPMENT SHALL BE MOUNTED AS SHOWN. WHERE DETAILS ARE NOT PROVIDED, THE <br />SUBCONTRACTOR SHALL USE DILIGENT EFFORTS TO MOUNT EQUIPMENT SUCH THAT IT WILL <br />BE CLEAN, LEVEL, AND SOLID. <br />7. ALL SURFACES SHALL BE PATCHED AND PAINTED AROUND NEW DEVICES AND EQUIPMENT <br />TO MATCH EXISTING FINISHES. <br />8. ANY METAL SHAVINGS RESULTING FROM SITE WORK SHALL BE CLEANED FROM ROOF SURF <br />ACES, ENCLOSURES, AND ANY ADDITIONAL AREAS WHERE OXIDIZED OR CONDUCTIVE METAL <br />SHAVINGS <br />MAY CAUSE RUST, ELECTRICAL SHORT CIRCUITS, OR OTHER DAMAGE. <br />9. BEAMS OR JOISTS SHALL NOT BE DRILLED UNLESS SPECIFICALLY AUTHORIZED BY <br />CONTRACTOR. <br />10. WHEN MOUNTING EQUIPMENT TO EXISTING REINFORCED CONCRETE, USE CARE TO AVOID <br />CUTTING OR DAMAGING THE REINFORCING BARS. POWER DRIVEN PINS ARE NOT TO BE USED. <br />11. IF THE OCCUPANCY STRUCTURE IS RESIDENTIAL, IT WILL BE UPGRADED TO CONFIRM WITH <br />2022 CALIFORNIA RESIDENTIAL CODE REQUIREMENTS FOR CARBON MONOXIDE ALARMS <br />(SECTION <br />R315), AND SMOKE DETECTORS. <br />12. CONTRACTOR SHALL FURNISH ALL SUPERVISION, TEMPORARY FRAGILITIES, AND OTHER <br />NECESSARY ITEMS AS REQUIRED TO COMPLETE THE WORK SPECIFIED TO PROVIDE A <br />COMPLETE AND USABLE SYSTEM. <br />13. DRAWINGS ARE DIAGRAMMATIC, SITE CONDITIONS SHALL PREVAIL. IF NO SCALE IS GIVEN, <br />DRAWINGS ARE NOT TO SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY SUBCONTRACTOR <br />AND SUBCONTRACTORS IN THE FIELD UPON COMMENCEMENT OF CONSTRUCTION. <br />14. SUBCONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AT ,JOB <br />SITE AND REPORT ANY DISCREPANCIES TO CONTRACTOR'S SUPERINTENDENT, PROJECT <br />MANAGER OR CONSTRUCTION MANAGER BEFORE COMMENCING WORK. <br />15. ALL CONDUCTOR SIZES AND TYPES SPECIFIED IN SINGLE LINE AND /OR THREE LINE <br />DIAGRAMS ARE TO BE INSTALLED. <br />GOVERNING CODES <br />WIRING AND CONDUIT NOTES: <br />· ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS <br />PURPOSE AND APPROVED FOR THE SITE APPLICATIONS <br />· ALL PV CABLES AND HOMERUN WIRES BE #10AWG *USE-2, PV <br />WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY MFR, <br />OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER <br />BOXES AS REQUIRED <br />· ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED <br />ACCORDING TO [CEC 690.8 (A)(1) & (B)(1)], [CEC 240] [CEC <br />690.7] FOR MULTIPLE CONDUCTORS <br />· ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT <br />SHALL BE DERATED ACCORDING TO [CEC TABLE 310.15 <br />(B)(2)(C)] BLACK ONLY** <br />· EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C <br />RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR <br />600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT <br />WIRE FROM SHARP EDGES <br />· PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED <br />THHN/THWN-2 INSULATED, 90°C RATED, WET AND UV <br />RESISTANT, RATED FOR 600V PER CEC 2022 OR 1000V PER <br />CEC 2022 <br />· 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH <br />THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR <br />IDENTIFIED BY OTHER EFFECTIVE MEANS <br />· ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE <br />CIRCUIT PROTECTION <br />·VOLTAGE DROP LIMITED TO 2% <br />·AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE <br />A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, <br />NEUTRAL- WHITE/GRAY <br />(E) SYSTEM RATING <br />5.12 KWDC <br />4.57 CEC KWAC <br />TOTAL SYSTEM <br />RATING <br />9.86 KWDC <br />8.89 CEC KWAC <br />Reviewed and approved <br />Neal Shah, P.E. <br />CA Lic. No. 5107 <br />01/07/2025 <br />Bldg #101122627 <br />Elect #20185251 <br />*The scope of the plans is for the <br />installation of the solar photovoltaic <br />system only and the approval is subject <br />to compliance with all applicable city <br />and state codes and regulations <br />regarding construction. The approval of <br />the plans does not constitute any <br />certification of the accuracy, <br />completeness, or building permit status <br />of the existing buildings and structures <br />as shown. ** <br />617 S Broadway <br />2/25/2025