My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
600 S Harbor Blvd - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Harbor Blvd
>
600 S Harbor Blvd
>
600 S Harbor Blvd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:17:31 PM
Creation date
6/6/2025 1:16:57 PM
Metadata
Fields
Template:
Plan
Permit Number
20184269
30147911
40139623
101121206
Full Address
600 S Harbor Blvd
Rectangle
ID:
1
Creator:
Import Agent
Created:
6/6/2025 1:17 PM
Modified:
6/6/2025 9:40 AM
ID:
2
Creator:
Import Agent
Created:
6/6/2025 1:17 PM
Modified:
6/6/2025 9:40 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
TRE. <br />ROOM 1 <br />100SF <br />TRE. <br />ROOM 2 <br />100 SF <br />TRE. <br />ROOM 3 <br />100SF <br />TRE. <br />ROOM 4 <br />100SF <br />TRE. <br />ROOM 5 <br />100 SF <br />TRE. <br />ROOM 6 <br />170SF <br />CONSULT. <br />STERILIZATION <br />PRIVATE <br />OFFICE <br />77 SF <br />RE <br />C <br />E <br />P <br />T <br />I <br />O <br />N <br />/ <br /> <br />C <br />H <br />E <br />C <br />K <br />- <br />O <br />U <br />T <br />STAFF <br />LOUNGE <br />178 SF <br />STORAGE <br />91SF <br /> DENTAL MECH. <br />/JAN. CLOSET <br />50SF <br />IMAGING <br />ALCOVE <br />100SF <br />STOR <br />8SF <br />I. <br />T <br />. <br /> <br />C <br />L <br />O <br />S <br />E <br />T <br />STORAGE <br />WAITING <br />514 S.F. <br />34 OCC <br />CORRIDOR <br />503 SF <br />BUSINESS <br />OFFICE <br />150 SF <br />ACCESSIBLE <br />RESTROOM <br />51 SF <br />ACCESSIBLE <br />RESTROOM <br />60SF <br />0.0 <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA ENERGY CODE <br />FLAMMABLE, HAZARDOUS MATERIALS SHALL NOT BE STORED ON PROPERTY. <br />HVAC UNITS ARE EXISTING ON ROOF, DUCTWORK ALTERATION ONLY. <br />ALL EXTERIOR SIGNAGE UNDER SEPARATE PERMIT. <br />NO MEDICAL GASSES WILL BE INSTALLED. <br />NEW DOORS TO, AND WITHIN AREA OF WORK SHALL BE ACCESSIBLE <br />1ST FLOOR ENTRANCE <br />1. <br />2. <br />3. <br />4. <br />FIRE SPRINKLER MODIFICATIONS IF REQUIRED, SHALL BE UNDER SEPARATE PERMIT. <br />6. <br />7. <br />8. NO STRUCTURAL CHANGES <br />VICINITY MAP <br />SHEET INDEX <br />BUILDING DEPT NOTESPROJECT SUMMARY <br />SHEET <br />DRAWN BY <br />CHECKED BY <br />SCALE <br />DATE <br />AL <br />L <br /> <br />C <br />O <br />U <br />N <br />T <br />Y <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br />26 <br />4 <br />7 <br /> <br />G <br />A <br />T <br />E <br />W <br />A <br />Y <br /> <br />R <br />D <br /> <br />S <br />T <br />E <br /> <br />1 <br />0 <br />2 <br />- <br />2 <br />2 <br />7 <br />CA <br />R <br />L <br />S <br />B <br />A <br />D <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />0 <br />9 <br />LI <br />C <br />. <br /> <br />B <br /> <br />- <br /> <br />6 <br />6 <br />9 <br />2 <br />4 <br />4 <br />56 <br />2 <br />- <br />9 <br />8 <br />9 <br />- <br />3 <br />3 <br />5 <br />0 <br />-I <br />M <br />P <br />O <br />R <br />T <br />A <br />N <br />T <br /> <br />N <br />O <br />T <br />E <br />- <br /> <br />Th <br />e <br /> <br />i <br />d <br />e <br />a <br />s <br />/ <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />i <br />n <br />c <br />l <br />u <br />d <br />e <br />d <br /> <br />h <br />e <br />r <br />e <br />i <br />n <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />s <br />o <br />l <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br /> <br />A <br />l <br />l <br /> <br />C <br />o <br />u <br />n <br />t <br />y <br /> <br />C <br />o <br />n <br />s <br />t <br />r <br />u <br />c <br />t <br />i <br />o <br />n <br />, <br /> <br />a <br />n <br />d <br /> <br />pr <br />o <br />t <br />e <br />c <br />t <br />e <br />d <br /> <br />u <br />n <br />d <br />e <br />r <br /> <br />c <br />o <br />p <br />y <br />r <br />i <br />g <br />h <br />t <br />. <br /> <br />T <br />h <br />e <br />y <br /> <br />m <br />a <br />y <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />u <br />s <br />e <br />d <br /> <br />o <br />r <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />co <br />n <br />s <br />e <br />n <br />t <br /> <br />o <br />f <br /> <br />A <br />l <br />l <br /> <br />C <br />o <br />u <br />n <br />t <br />y <br /> <br />C <br />o <br />n <br />s <br />t <br />r <br />u <br />c <br />t <br />i <br />o <br />n <br /> <br />a <br />n <br />d <br /> <br />f <br />u <br />l <br />l <br /> <br />p <br />a <br />y <br />m <br />e <br />n <br />t <br /> <br />o <br />f <br /> <br />a <br />n <br />y <br /> <br />a <br />s <br />s <br />o <br />c <br />i <br />a <br />t <br />e <br />d <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br /> <br />f <br />e <br />e <br />s <br />. <br /> <br />T <br />h <br />i <br />s <br />do <br />c <br />u <br />m <br />e <br />n <br />t <br /> <br />h <br />a <br />s <br /> <br />b <br />e <br />e <br />n <br /> <br />p <br />r <br />e <br />p <br />a <br />r <br />e <br />d <br /> <br />a <br />s <br /> <br />a <br />n <br /> <br />i <br />n <br />s <br />t <br />r <br />u <br />m <br />e <br />n <br />t <br /> <br />o <br />f <br /> <br />p <br />r <br />o <br />f <br />e <br />s <br />s <br />i <br />o <br />n <br />a <br />l <br /> <br />s <br />e <br />r <br />v <br />i <br />c <br />e <br />. <br /> <br />Us <br />e <br /> <br />b <br />y <br /> <br />a <br />n <br />y <br /> <br />ot <br />h <br />e <br />r <br /> <br />c <br />o <br />n <br />t <br />r <br />a <br />c <br />t <br />o <br />r <br /> <br />r <br />e <br />q <br />u <br />i <br />r <br />e <br />s <br /> <br />a <br /> <br />f <br />u <br />l <br />l <br /> <br />r <br />e <br />l <br />e <br />a <br />s <br />e <br /> <br />o <br />f <br /> <br />l <br />i <br />a <br />b <br />i <br />l <br />i <br />t <br />y <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />t <br />o <br /> <br />p <br />e <br />r <br />m <br />i <br />t <br /> <br />i <br />s <br />s <br />u <br />a <br />n <br />c <br />e <br />. <br /> <br />Di <br />s <br />c <br />r <br />e <br />p <br />e <br />n <br />c <br />i <br />e <br />s <br /> <br />m <br />u <br />s <br />t <br /> <br />b <br />e <br /> <br />b <br />r <br />o <br />u <br />g <br />h <br />t <br /> <br />t <br />o <br /> <br />t <br />h <br />e <br /> <br />a <br />t <br />t <br />e <br />n <br />t <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />e <br />r <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />t <br />o <br /> <br />c <br />o <br />n <br />s <br />t <br />r <br />u <br />c <br />t <br />i <br />o <br />n <br /> A <br />L <br />L <br /> <br />D <br />I <br />M <br />E <br />N <br />S <br />I <br />O <br />N <br />S <br /> <br />S <br />U <br />B <br />J <br />E <br />C <br />T <br /> <br />T <br />O <br /> <br />J <br />O <br />B <br /> <br />S <br />I <br />T <br />E <br /> <br />V <br />E <br />R <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />. <br /> <br />c ALL RIGHTS RESERVED <br />DR <br />. <br /> <br />I <br />N <br /> <br />G <br />I <br /> <br />S <br />O <br />N <br /> <br />60 <br />0 <br /> <br />S <br />. <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br />B <br />L <br />V <br />D <br />. <br /> <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br /> <br />1/4"= 1' <br />C A L I F O R N I A C O U N C I L F O R INTERIOR <br />DESIGN <br />CERTIFICATIONCALIFORNIA COUNCIL FORINTERIOR <br />DESIGN <br />CERTIFICATION <br />CERTIFIED INTERIOR DESIGNER <br />E X P I R E S 9 - 9 - 2 5 C I D # 6 3 4 5 <br />ERIK JORDAN <br />COMMERCIAL <br />5. <br />2761TOTAL FLOOR AREA <br />BOCCUPANCY GROUP <br />49OCCUPANT LOAD <br />V-BSITE CONSTRUCTION <br />1NUMBER OF STORIES <br />FIRE DEPARTMENT NOTES <br />INTERIOR T.I. GENERAL DENTAL OFFICE. <br />NO MEDICAL GASSES WILL BE INSTALLED. <br />EXISTING ROOFTOP MECHANICAL EQUIPMENT WILL BE USED. <br />ALTERATION OF DUCTING ONLY. <br />NEW T-BAR AND HARD LID CEILING AS INDICATED ON PLAN <br />2 NEW ACCESSIBLE RESTROOMS <br />NO STRUCTURAL CHANGES. <br />SCOPE OF WORK <br />1. Fire Department final inspection required. Schedule all inspections 72 hours in advance by calling fire inspector <br />2. Provide 2A 10BC minimum rated fire extinguishers to be located on each level within 75 feet of travel distance from all <br />areas. Travel distance is 30 feet in areas having flammable liquids. <br />3. Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort. Provide <br />self-releasing locking devices on exit doors <br />4. A sign that reads "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED" with a minimum one (1) inch <br />letters shall be provided adjacent to the main exit (1) door only <br />5. EXIT" signs shall be in block letters, a minimum of six (6) inches high with a stroke of not less than 3/4 inch. <br />Luminance on face of sign shall be 50 LUX. <br />6. EXIT" signs shall be electrically illuminated and energized from separate circuits. Show on electrical plan(s). One of <br />the above circuits shall be part of the emergency lighting system <br />7. Exit signs shall be provided in accordance with current editions of C.B.C. and C.F.C. Show location on floor or <br />reflected ceiling plans). <br />8. Storage, dispensing, or use of any flammable or combustible liquids, flammable gases, and hazardous chemicals shall <br />comply with Uniform Fire Code requirements <br />9. Medical gas systems shall comply with N.F.P.A. Standard 99 (if applicable to this build) <br />10. An approved knox box must exist on the building or a knox box must be provided for the building. CFC 506 <br />11. The Fire Sprinkler System requirements and/or modifications require a separate plan check submittal and <br />approval. <br />12. Fire extinguishers must be installed per CFC Section 906. Start the placement of fire extinguisher near the exterior <br />exit doors. Mount the fire extinguisher in a visible and accessible location, 3½' to 5' above the finish floor to the <br />handle. Buildings with multiple floors must have at least one fire extinguisher per floor. <br />13. Light Hazard (offices, classrooms, churches, assembly rooms, residential) Occupancies require "2A10BC" fire <br />extinguishers. The maximum coverage area is 5,000 sq. ft per extinguisher and the maximum travel distance is 75'. <br />14. All doors designated as exits, must be equipped with panic or lever type hardware. CFC 1010.1.9 <br />TITLE0.0 <br />GENERAL NOTESGN1 <br />FLOOR PLANA1.0 <br />PLUMBING LAYOUTP1 <br />PLUMBING PIPING DIAGRAMP2 <br />ELECTRICAL LAYOUT PLANE1 <br />DETAIL PAGED1 <br />DETAIL PAGED2 <br />MECHANICAL LAYOUTM1 <br />MECHANICAL ACCEPTANCE FORMSM2 <br />REFLECTED CEILING PLANA2.0 <br />DETAIL PAGED3 <br />SITE PLANA-0.1 <br />QUIET ROCK INSTALLATION INSTRUCTIONSQR1 <br />FIRE SPRINKLERS NO <br />PLUMBING PIPING DIAGRAMP3 <br />RESTROOM ELEVATIONSA1.1 <br />ELECTRICAL ENGINEERED PLANE1.0 <br />ELECTRICAL ENGINEERED PLANE2.0 <br />ELECTRICAL ENGINEERED PLANE3.0 <br />ELECTRICAL ENGINEERED PLANE4.0 <br />CAL GREENCG1 <br />CAL GREENCG2 <br />CAL GREENCG3 <br />EGRESS DISTANCES <br />P: 32"PROVIDED EGRESS WIDTH <br />F FIRE EXTINGUISHER CABINET <br />PER 20122 INTERNATIONAL BUILDING CODE, TABLE 1017.2, EXIT ACCESS TRAVEL <br />DISTANCE WITH SPRINKLER SYSTEM < 300' <br />PATH ID <br />1A <br />1B <br />1C <br />1D <br />TRAVEL DISTANCE <br />74' <br />LIFE SAFETY LEGEND <br />SYMBOL DESCRIPTION <br />EXIT LIGHTS <br />EGRESS TRAVEL PATH <br />47' <br />FIXTURE CALCULATIONS <br />OCCUPANCY: BUSINESS - B <br />BUILDINGS FOR THE TRANSACTION OF BUSINESS, <br />PROFESSIONAL SERVICES, OTHER SERVICES <br />INVOLVING MERCHANDISE, OFFICE BUILDINGS, <br />BANKS, LIGHT INDUSTRIAL AND SIMILAR USES <br />REQUIRED: <br />PROVIDED: <br />WATER CLOSET <br />1 1 <br />OCCUPANTS: 30 <br />LAVATORIES <br />MALE FEMALE MALE FEMALE <br />1 1 <br />(24 MALE 24 FEMALE) <br />BATHTUBS OR <br />SHOWERS OTHER <br />1 SERVICE SINK <br />OCCUPANCY CALCULATIONS <br />OCCUPANCY TYPE <br />BUSINESS AREAS <br />TOTAL: <br />AREA <br />2761 SF <br />SF PER <br />OCC. <br />150 <br />OCC. <br />LOAD <br />49 <br />DRINKING <br />FOUNTAIN OR <br />SF PER OCC <br />LOBBY 1:15 <br />514 S.F/15= 34 OCC <br />2761 SF - 514 (LOBBY) = 2247 SF @ 150 PER OCC= 15 OCC + LOBBY (34) = 49 OCC TOTAL <br />BOTTLE FILLER <br />1A <br /> <br />- <br /> <br />7 <br />4 <br />' <br />1A <br /> <br />- <br /> <br />7 <br />4 <br />' <br />1A <br /> <br />- <br /> <br />9 <br />2 <br />' <br />1B - 47' <br />1B - 47' <br />1B <br />- 92 <br />' <br />F <br />F <br />F <br />P: 32" <br />P: 32" <br />P: 32" <br />P: 32"1 1 1 1 1 2 NEW UNISEX RR <br />PLUMBING ACCEPTANCE FORMSP4 <br />MECHANICAL MANDATORY MESURESM2 <br />1C <br /> <br />- <br /> <br />5 <br />4 <br />' <br />1C <br /> <br />- <br /> <br />5 <br />4 <br />' <br />54' <br />PLUMBING SCOPE OF WORK: <br />TWO NEW RESTROOMS, 6 EXAM SINKS, WATER HEATER, <br />MOP SINK, LOUNGE SINK, STERILE SINK, TWO FLOOR <br />DRAINS, AIR AND VACUUM (LEVEL 3) <br />MECHANICAL SCOPE OF WORK: <br />· REPLACE 2 EXISTING HEAT PUMPS WITH NEW. NEW <br />DUCTING THROUGHOUT SPACE, 4 NEW EXHAUST <br />FANS. <br />· DUCTWORK AND PLENUMS TO BE CONSTRUCTED TO <br />SEAL CLASS A. SEE 2022 CEC 120.4(B). <br />· MANDATORY REQUIREMENT CLARIFICATIONS TO <br />SPACES FOR WHICH OCCUPANT SENSOR <br />VENTILATION CONTROL DEVICES ARE REQUIRED. SEE <br />2022 CEC 120.1(D)5. <br />· DUCT LEAKAGE TESTING REQUIRED <br />Bldg # 101121206 <br />Elect #20184269 <br />Plumb #30147911 <br />Mech #40139623 <br />APPROVALS: <br /> <br />PLNG - F. Arias <br />BLDG - T. Le <br />POLICE - B. Martin <br />PUBLIC WORKS - Y. Soto <br />ELECT - M. Smith/T. Le <br />PLUMB/MECH - T. Luka <br />600 S Harbor Blvd <br />3/17/2025
The URL can be used to link to this page
Your browser does not support the video tag.