Laserfiche WebLink
MSPACCB <br />5514 RHONDA AVENUE, SANTA ANA, CA 92703 <br />PV-5 <br />PLACARDS <br />ELECTRIC SHOCK HAZARD <br />THE DC CONDUCTORS OF THIS PHOTOVOLTAIC <br />SYSTEM ARE UNGROUNDED AND MAY BE <br />ENERGIZED <br />LABEL LOCATION <br />PV COMBINER BOX <br />[To be used when inverter is ungrounded] <br />WARNING <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH LINE AND LOAD SIDES <br />MAY BE ENERGIZED IN THE OPEN POSITION <br /> WARNING <br />LABEL LOCATION <br />AC DISCONNECT, <br />POINT OF INTERCONNECTION <br />PER CODE: CEC 690.13 <br />SOLAR DISCONNECT <br />LABEL LOCATION <br />AC DISCONNECT, POINT OF INTERCONNECTION <br />PER CODE: CEC 690.13(B) <br />! <br />! <br />SYSTEM UTILIZES MICROINVERTERS LOCATED UNDER EACH SOLAR MODULE <br />LABEL LOCATION <br />POINT OF INTERCONNECTION <br />PER CODE: CEC 705.12(B)(3-4) AND 690.59 <br /> WARNING <br />DUAL POWER SOURCE SECOND <br />SOURCE IS PHOTOVOLTAIC <br />SYSTEM <br />! <br />LABEL LOCATION <br />POINT OF INTERCONNECTION <br />PER CODE: CEC 705.12(B)(3)(2) <br />WARNING <br />POWER SOURCE OUTPUT <br />CONNECTION <br />DO NOT RELOCATE THIS <br />OVER-CURRENT DEVICE <br />RATED AC OPERATING CURRENT <br />AC NOMINAL OPERATING VOLTAGE <br />40.50 <br />240 <br />PHOTOVOLTAIC SYSTEM AC DISCONNECT SWITCH <br />AMPS AC <br />VAC <br />LABEL LOCATION <br />AC DISCONNECT, POINT OF INTERCONNECTION <br />PER CODE: CEC 690.54 <br />LABEL LOCATION <br />CONDUIT, PV COMBINER BOX <br />PER CODE: CEC 690.31(D)(2) <br />WARNING:PHOTOVOLTAIC <br />POWER SOURCE <br />LABEL LOCATION <br />PV COMBINER BOX, JUNCTION BOX (ROOF), <br />AC DISCONNECT <br />WARNING-ELECTRIC SHOCK HAZARD <br />NO USER SERVICEABLE PARTS INSIDE <br />CONTACT AUTHORIZED SERVICE <br />PROVIDE FOR ASSISTANCE <br />NOTES <br />1.PLACARDS SHALL MEET THE REQUIREMENTS <br />OF ARTICLES 690 AND 705, UNLESS <br />OTHERWISE SPECIFIED PER LOCAL AHJ <br />REQUIREMENTS. <br />2.PLACARDS SHALL MEET THE REQUIREMENTS <br />OF SECTION 110.21(B) AS REQUIRED AND <br />SHALL COMPLY WITH ANSI Z535.4-2011, <br />PRODUCT SAFETY SIGNS AND LABELS. <br />3.PLACARDS SHALL BE PERMANENTLY AFFIXED <br />TO THE EQUIPMENT OR WIRING METHOD. <br />4.PLACARDS SHALL BE SUFFICIENT <br />DURABILITY TO WITHSTAND THE <br />ENVIRONMENT INVOLVED AND SHALL NOT BE <br />HANDWRITTEN. <br />5.PLACARDS SHALL NOT COVER EXISTING <br />MANUFACTURER LABELS. <br />6.WARNING SIGNAGE TEXT SHALL BE MINIMUM <br />3/8" TALL. <br />POWER TO THIS BUILDING IS ALSO <br />SUPPLIED FROM THE FOLLOWING <br />SOURCES WITH DISCONNECTS LOCATED <br />AS SHOWN <br />!!CAUTION:MULTIPLE SOURCES <br />OF POWER <br />LABEL LOCATION <br />SERVICE PANEL <br />PER CODE: CEC 705.10 <br />LABEL LOCATION <br />AC DISCONNECT, PV COMBINER BOX <br />PER CODE: CEC 690.56(C)(2) <br />RAPID SHUTDOWN <br />SWITCH FOR SOLAR PV <br />SYSTEM <br />LABEL LOCATION <br />AC DISCONNECT, <br />POINT OF INTERCONNECTION <br />PER CODE: CEC 690.56(C) <br /> SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRICPV PANELS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE <br /> "OFF" POSITION TO <br /> SHUT DOWN PV SYSTEM <br />AND REDUCE <br />SHOCK HAZARD <br />IN THE ARRAY <br />LICENSE TYPE: C-10 <br />NEXT PHASE ELECTRIC <br />APN: 09920301 <br />PHONE NUMBER: (661) 878-7576 <br />ADDRESS: 5409 ALDRIN COURT, <br />BAKERSFIELD, CA 93313 <br />ADDRESS: 5514 RHONDA AVENUE, <br />SANTA ANA, CA 92703 <br />COORDINATES: 33.750842, -117.941808 <br />CONTRACTOR INFORMATION <br />NAME: HIEP TRINH <br />CUSTOMER INFORMATION <br />PROJECT ID AUR-1002094 <br />DATE 10/3/2024 <br />CREATED BY SSB <br />SIGNATURE <br />LICENSE NUMBER: 1025263 <br />12.150kW DC / 9.750kW AC / 11.012kW <br />CEC AC ROOF MOUNT PV SYSTEM <br />(N) UTILITY METER WITH MAIN SERVICE <br />PANEL (EXTERIOR) (UNDER PATIO) <br />(N) ENPHASE IQ COMBINER 4 <br />(EXTERIOR) (UNDER PATIO) <br />(N) AC DISCONNECT (EXTERIOR) <br />(UNDER PATIO) <br />(N) PV ARRAY <br />RAPID SHUTDOWN <br />COMPLIANT SYSTEM <br />5514 W Rhonda <br />Ave11/27/2024