Laserfiche WebLink
Page 5 of 8 <br />1760 Chicago Ave Ste J13, Riverside, CA 92507 (951) 405-1733 info@currentrenewableseng.com <br />Roof Framing Checks: <br />Force Checks <br />LC1: D+S Check 1 <br />Applied Moment (lb-ft):420.2 <br />Applied Shear (lbs):128.5 <br />Allowable Moment (lb-ft):975.1 <br />Allowable Shear (lbs):1,138.5 <br />Moment DCR:0.431 <br />Shear DCR:0.113 <br />LC2: D+0.6W Check 1 <br />Applied Moment (lb-ft):825.8 <br />Applied Shear (lbs):252.5 <br />Allowable Moment (lb-ft):1,356.7 <br />Allowable Shear (lbs):1,584.0 <br />Moment DCR:0.609 <br />Shear DCR:0.159 <br />LC3: D+0.75(S+0.6W)Check 1 <br />Applied Moment (lb-ft):724.4 <br />Applied Shear (lbs):221.5 <br />Allowable Moment (lb-ft):1,356.7 <br />Allowable Shear (lbs):1,584.0 <br />Moment DCR:0.534 <br />Shear DCR:0.140 <br />LC4: 0.6D+0.6W Check 1 <br />Applied Moment (lb-ft):657.7 <br />Applied Shear (lbs):201.1 <br />Allowable Moment (lb-ft):1,356.7 <br />Allowable Shear (lbs):1,584.0 <br />Moment DCR:0.485 <br />Shear DCR:0.127 <br />522 S Raitt St Unit# <br />210/4/2024