<br />15375 Barranca Pkwy #B205 PROJECT: SOTO RESIDENCE <br />Irvine, Ca 92618 ADDRESS: 5510 ROOSEVELT AVE <br />(714) 267-6561 CELL SANTA ANA, CA <br />(951) 934-5444 FAX DATE: 07- 2024 <br /> <br /> <br /> <br />CODE: 2022 CALIFORNIA BUILDING CODE, ASCE 7-16 <br />TIMBER <br /> <br />Douglas Fir-Larch - 19% max. moisture content <br />2x4 #2: Fb=1315/1510 psi Fv=95 psi <br />2x6 #2: Fb=1140/1310 psi E=1.6 E6 psi <br />2x8 #2: Fb=1055/1210 psi <br />2x10 #2: Fb=.965/1105 psi <br />2x12 #2: Fb= 875/1005 psi <br />2x14 #2: Fb= 790/ 905 psi <br />It is recommended that lumber be free of heart center. Glued <br />Laminated Beams: Douglas Fir-Larch <br />Lumber #2 /#1 <br />4x6,4x8 :Fb=1140/1300 psi; Fv=95 psi <br />4x10 : Fb=1050/1200 psi; E=1.6 E6 psi <br />4x12 : Fb= 965/1100 psi <br />4x14,4x16 : Fb= 875/1000 psi <br />Lumber : #1 / S.S. <br />6x10: Fb=1350/1600 psi, Fv=85 psi <br />6x12: Fb=1350/1600 psi, E=1.6 E6 psi <br /> PARALLAM PSL 2.0 E <br /> Ind. App. Grade: Fb=2400 psi; Fv=165; E=1.8 E6 psi Fb=2900 psi, Fv=290 psi; E=2.0 E6 psi <br /> MICROLLAM LVL M=L: Fb=2600 psi Fv=285 psi; E=1.8 E6 psi <br />CONCRETE <br />1. Dry pack shall be composed of one part Portland cement to not more than three parts sand. <br />2. All structural concrete …………………………...fc = 3000 psi <br />All slab-on-grade/continuous footings/pads……...fc = 2500 psi <br />All concrete shall reach minimum compressive strength at 28 days. <br />REINFORCING STEEL <br />1. All reinforcing shall be A.S.T.M. A -615-40 for #5 bars and smaller. <br />All reinforcing shall be A.S.T.M. A -615-60 for #6 bars and larger. <br />Welded wire fabric to be A.S.T.M. A -185, lap 1-1/2 spaces, 9" min. <br />2. Splicing of bars shall have lapping of 40 dia. or 2'-0" min. in all continuous concrete reinforcement (30 dia. for <br />compression). <br />Masonry reinforcement shall have lapping of 40 dia. or 21-0". This is in all cases U.N.O. <br />3. All reinforcing bars shall be accurately and securely placed before pouring concrete, or grouting masonry. <br />4. Concrete protection for reinforcement shall be at least equal to the diameter of the bars. Cover shall be as follows, <br />U.N.O.: <br />A. Poured against earth ……………………3" <br />B. Poured against form below grade……..2" <br />C. Slabs on grade (from top of slab)……..1" <br />D. Columns and beams to main bars……..2" <br />STRUCTURAL STEEL <br /> <br />1. Fabrication and erection of structural steel shall be in accordance with "Specifications for the Design, Fabrication and <br />Erection of Structural Steel Buildings", AISC, current edition. Steel to conform to ASTM A36. Round pipe columns <br />shall conform to ASTM A53, Grade B. Square/Rectangular steel tubes ASTM A500, Grade B. <br />2. All welding shall be performed by certified welders, using the Electric Shielded Arc Process at licensed shops or <br />otherwise approved by the Bldg. Dept. Continuous inspection required for all field welding. <br />3. All steel exposed to weather shall be hot -dip galvanized after fabrication, or other approved weatherproofing method. <br />4. Where finish is attached to structural steel, provide 1/2"o bolt holes 4'-0" o.c. for attachment <br />of nailers. See architectural drawings for finishes (Nelson studs 1/2" x 3" CPL may replace bolts). <br />MASONRY <br />1. Concrete block shall be of sizes shown on architectural drawings and/or called for in specifications and conform to <br />ASTM C-90, grade N medium weight units with max. linear shrinkage of 0.06% <br />2. All vertical reinforcing in masonry walls not retaining earth shall be located in the center of the wall (U.N.O.), <br />retaining walls are to be as shown in details. <br />3. All cells with steel are to be solid grouted, except retaining walls where all cells are to be solid grouted. <br />1 OF 4 <br />5510 W Roosevelt <br />Ave12/10/2024