Laserfiche WebLink
#1 <br />#2 <br />109' 8" <br />95 <br />' <br /> <br />3" <br />99' 11" <br />48 <br />' <br /> <br />2 <br />" <br />MSP <br />BLP <br />BG <br />RSD DA <br />JBA <br />26' <br />21'-11" <br />14 <br />' <br />- <br />6 <br />" <br />1'-9" <br />SUB <br />BAT <br />ARRAY LOCATION(S) <br />PROJECT SITE <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />DATE DESCRIPTION <br />REVISIONS <br />PV-1 <br />HOMEOWNER INFO <br />11" X 17" <br />SIGNATURE & SEAL <br />INITIAL DESIGN 7/12/2024 00 <br />Change Request 7/26/2024 A <br />Change Request 8/01/2024 B <br />Change Request 11/18/2024 C <br />COVER PAGE <br />& SITE PLAN <br />CONTRACTOR: AMECO SOLAR & ROOFING <br />ADDRESS: 4705 LAUREL CANYON BOULEVARD, <br />VALLEY VILLAGE, CA, USA <br />PHONE: 5626334400 <br />EMAIL: info@amecosolar.com <br />LICENSE #: 1053172-B, C-10 <br />LICENSE HOLDER #: OREN TAMIR <br />SA <br />N <br />D <br />E <br />E <br />P <br /> <br />T <br />A <br />L <br />L <br />U <br />R <br />I <br />39 <br />0 <br />2 <br /> <br />A <br />L <br />D <br />E <br />R <br /> <br />S <br />T <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />92 <br />7 <br />0 <br />7 <br /> <br />U <br />S <br />A <br />AP <br />N <br />: <br /> <br />4 <br />1 <br />0 <br />- <br />0 <br />3 <br />2 <br />- <br />1 <br />7 <br /> <br /> <br /> <br />PH <br />O <br />N <br />E <br />: <br /> <br />+ <br />1 <br />7 <br />1 <br />4 <br />9 <br />0 <br />0 <br />0 <br />4 <br />0 <br />9 <br />EM <br />A <br />I <br />L <br />: <br /> <br />N <br />/ <br />A <br />PHOTOVOLTAIC ROOF MOUNT & ENERGY SYSTEM <br />22 MODULES - SYSTEM SIZE STC (10.120 kW DC /11.500 kW AC) <br />3902 ALDER ST, SANTA ANA, CA 92707 USA (33.6953927, -117.8690450 ) <br />GOVERNING CODES <br />● 2022 CALIFORNIA FIRE CODE <br />● 2022 CALIFORNIA BUILDING CODE <br />● 2022 CALIFORNIA RESIDENTIAL CODE <br />● 2022 CALIFORNIA ELECTRICAL CODE <br />GENERAL NOTES <br />1) ALL PANELS, SWITCHES, ETC. SHALL HAVE SUFFICIENT GUTTER SPACE AND <br />LUGS IN COMPLIANCE WITH UL REQUIREMENTS TO ACCOMMODATE <br />CONDUCTORS SHOWN. <br />2) THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE <br />LOCAL JURISDICTION AND UTILITY IS OBTAINED. <br />3) ALL EXTERIOR ELECTRICAL DEVICES AND EQUIPMENT INCLUDING THOSE <br />THAT ARE EXPOSED TO OUTSIDE ENVIRONMENT SHALL BE WEATHERPROOF <br />AND SHALL BE LISTED BY 'UL' FOR THE TYPE OF APPLICATION AND 'UL' LABEL <br />SHALL APPEAR ON ALL ELECTRICAL EQUIPMENT. <br />4) WIRING METHOD SHALL BE EMT ABOVE GROUND MOUNTED IN CONCEALED <br />SPACES (UNLESS APPROVED OTHERWISE) AND SCHEDULE-40 PVC FOR <br />BELOW GROUND INSTALLATIONS UNLESS NOTED OTHERWISE. <br />5) AN OSHA APPROVED LADDER PROVIDING ACCESS TO ALL PORTIONS OF THE <br />ARRAY SHALL BE SECURED IN PRIOR TO REQUESTING INSPECTION. <br />6) IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL <br />GROUNDING ELECTRODE CONDUCTOR IF NECESSARY. <br />7) OCCUPANCY TYPE: R-3 <br />8) CONSTRUCTION TYPE: VB <br />SCALE: 1/16" = 1'-0" <br />SITE PLAN <br />HOUSE PHOTO <br />SCALE: NTS <br />VICINITY MAP <br />SCALE: NTS <br />SHEET INDEX <br />PV-1 COVER PAGE & SITE PLAN <br />PV-2 ROOF PLAN WITH MODULES <br />PV-2.1 STRING PLAN WITH MODULES <br />PV-3 ATTACHMENT DETAIL <br />PV-4 THREE LINE DIAGRAM <br />PV-5 WIRING CALCULATION <br />PV-5.1 EQUIPMENT ELEVATION <br />PV-5.2 PANEL SCHEDULES <br />PV-5.3 LOAD CALCULATION <br />PV-6 PLACARDS <br />PV-7+ EQUIPMENT SPECIFICATION <br />AHJ: SANTA ANA (CITY OF), CALIFORNIA <br />UTILITY: SOUTHERN CALIFORNIA EDISON CO <br />SYSTEM SUMMARY STC (10.120 KW DC / 11.500 KW AC) <br />STC DC: (22) 460W = 10.120 KW <br />STC AC: (1) 11500W = 11.500 KW <br />● (22) REC SOLAR PTE. LTD. REC460AA PURE-RX MODULES <br />● (1) TESLA INC. POWERWALL -3 WITH INTEGRATED 13.5 KWH BATTERY <br />● (1) TESLA BACKUP GATEWAY 2 <br />● 2X STRINGS OF 6 CONNECTED IN SERIES <br />● 2X STRINGS OF 5 CONNECTED IN SERIES <br />LE <br />G <br />E <br />N <br />D <br />NEW PV MODULE <br />FIRE SETBACK <br />ROOF ATTACHMENT <br />FRONT OF HOUSE <br />DIMENSIONS <br />PROPERTY LINE <br />RAFTER/TRUSS <br />RAIL <br />FENCE <br />GATE <br />JBA AC JUNCTION BOX <br />(NEW) <br />MSP MAIN SERVICE PANEL & UTILITY <br />METER (NEW, 400A) <br />BLP BACKUP LOAD PANEL <br />(NEW) <br />BG TESLA BACKUP <br />GATEWAY-2 (NEW) <br />BAT BATTERY <br />(NEW) <br />TESLA MCI -1 <br />ROOF ACCESS POINT <br />CONDUIT <br />STRING <br />DRIVEWAY <br />RSD RAPID SHUTDOWN <br />DISCONNECT (NEW) <br />AL <br />D <br />E <br />R <br /> <br />S <br />T <br />CONDUIT RUN <br />(ON ROOF) <br />DRIVEWAY <br />MAIN HOME <br />CEC-AC RATING - 9.461 KW <br />SUB SUB PANEL <br />(NEW) DA ESS DISCONNECT <br />(NEW) <br />Rev-C <br />Bldg # 101120972 <br />Elect #20184082 <br /> <br />APPROVALS: <br />ELECT - M. Smith <br />***The scope of the plans is for the installation of <br />the solar photovoltaic system only and the <br />approval is subject to compliance with all <br />applicable city and state codes and regulations <br />regarding construction. The approval of the plans <br />does not constitute any certification of the <br />accuracy, completeness, or building permit <br />status of the existing buildings and structures as <br />shown. *** <br />3902 S Alder St <br />4/30/2025