Laserfiche WebLink
STATE OF CALIFORNIA <br />Mechanical Systems CALIFORNIA ENERGY COMMISSION <br />CERTIFICATE OF COMPLIANCE NRCC-MCH-E <br />Project Name: Wells Fargo, Santa Ana Report Page: (Page 3 of 7) <br />Date Prepared: 2024-08-29T13:17:07-04:00 <br />Generated Date/Time:Documentation Software: Energy Code Ace <br />CA Building Energy Efficiency Standards - 2022 Nonresidential Compliance Report Version: 2022.0.000 <br />Schema Version: rev 20220101 <br />Compliance ID: 222657-0824-0002 <br />Report Generated: 2024-08-29 10:17:13 <br />F. HVAC SYSTEM SUMMARY (DRY & WET SYSTEMS) <br />Dry System Equipment Sizing (includes air conditioners, condensers, heat pumps, VRF, furnaces and unit heaters and DOAS systems) <br />01 02 03 04 05 06 07 08 09 10 11 <br />Name or Item <br />Tag <br />Equipment Category per <br />Tables 110.2, 140.4(a)2 and <br />170.2(c)3aii <br />Equipment Type per Tables 110.2 and <br />Title 20 <br />Smallest Size <br />Available1 <br />140.4(a) and <br />170.2(c)1 <br />Equipment Sizing per Mechanical Schedule (kBtu/h) <br />140.4(a&b), 170.2(c)1 & 170.2(c)2 <br />Heating Output2,3 Cooling Output2,3 Load Calculations3,4 <br />Per Design <br />(kBtu/h) <br />Rated <br />(kBtu/h) <br />Supp. <br />Heating <br />Output <br />(kBtu/h) <br />Sensible <br />Per Design <br />(kBtu/h) <br />Rated <br />(kBtu/h) <br />Total <br />Heating <br />Load <br />(kBtu/h) <br />Total <br />Sensible <br />Cooling <br />Load <br />(kBtu/h) <br />RTU-1 Unitary AC/ Cond. (no elec. <br />resistance)AC, air-cooled pkg (3 phase)Yes    64.8 91  70 <br />RTU-2 Unitary AC/ Cond. (no elec. <br />resistance)AC, air-cooled pkg (3 phase)Yes    35.3 51.7  40 <br />RTU-3 Unitary AC/ Cond. (no elec. <br />resistance)AC, air-cooled pkg (3 phase)Yes    35.3 51.7  40 <br />1FOOTNOTES: Equipment shall be the smallest size, within the available options of the desired equipment line, necessary to meet the design heating and cooling loads of the building per <br />140.4(a) and 170.2(c)1. Healthcare facilities are excepted. <br />2It is common practice to show rated output capacity on the equipment schedule. Sensible cooling output comes from specification sheet tables. <br />3 If equipment is heating only, leave cooling output and load blank. If equipment is cooling only, leave heating output and load blank. <br />4 Authority Having Jurisdiction may ask for load calculations used for compliance per 140.4(b) and 170.2(c). <br />Dry System Equipment Efficiency (other than Package Terminal Air Conditioners (PTAC) and Package Terminal Heat Pumps (PTHP), DX-DOAS and Dual Fuel Heat Pumps) <br />01 02 03 04 05 06 07 08 09 <br />Name or Item <br />Tag <br />Size Category <br />(Btu/h) <br />Heating Mode Cooling Mode <br />Rating <br />Condition <br />( °F) <br />Efficiency Unit <br />Minimum <br />Efficiency <br />Required per <br />Tables 110.2 / <br />Title 20 <br />Design Efficiency Efficiency Unit <br />Minimum <br />Efficiency <br />Required per <br />Tables 110.2 / <br />Title 20 <br />Design Efficiency <br />RTU-1 >=65,000 and <135,000     EER <br />IEER <br />11 <br />14.6 <br />12 <br />14.6 <br />3925 S Bristol <br />St-HVAC12/23/2024