Cooling Performance <br />Total gross capacity 54.8 MBH <br />Sensible gross capacity 38.4 MBH <br />Total net capacity 51.7 MBH <br />Sensible net capacity 35.3 MBH <br />Seasonal Efficiency (at ARI)15.40 SEER2 <br />Seasonal Efficiency (at ARI)14.50 SEER2 <br />Efficiency (at ARI)12.00 EER2 <br />Efficiency (at ARI)12.00 EER2 <br />Ambient DB temp.95.0 °F <br />Entering DB temp.80.0 °F <br />Entering WB temp.67.0 °F <br />Leaving DB temp.57.8 °F <br />Leaving WB temp.56.1 °F <br />Leaving air temp dew point 55.00 °F <br />Power input (w/o blower)3.50 kW <br />Sound power 79 dB(A) <br />Refrigerant <br />Refrigerant type R-410A   <br />Sys1 6 lbs 8 oz <br />Gas Heating Performance <br />Entering DB temp.60 °F <br />Heating output capacity (Max)56.0 MBH <br />Supply air 1600 CFM <br />Heating input capacity (Max)70 MBH <br />Leaving DB temp.92.4 °F <br />Air temp. rise 32.4 °F <br />SSE 80.0 % <br />Stages 2   <br />Supply Air Blower Performance <br />Supply air 1600 CFM <br />Ext. static pressure 0.6 IWG <br />Addl. Unit Losses (Options/Accessories)0.24 IWG <br />Blower speed 1206 HP <br />Max BHP of Motor (including service factor)2.90 HP <br />Duct location Bottom   <br />Motor rating 2.90 HP <br />Actual required BHP .97 HP <br />Power input 0.91 kW <br />Elevation 0 ft. <br />Drive type BELT   <br />Outside/Mixed Air <br />Outside Air Cfm 400 CFM <br />Electrical Data <br />Power supply 208-3-60 230-3-60 <br />Unit min circuit ampacity 25.9 Amps 26 Amps <br />Unit min over-current protection 30 Amps 30 Amps <br />Unit max over-current protection 35 Amps 35 Amps <br />Dimensions & Weight <br />Hgt 41 in.Len 74 in.Wth 49 in. <br />Weight with factory installed options 683 lbs <br />ERV Weight lbs <br />Clearances <br />Right 18 in.Front 18 in.Rear 18 in. <br />Top 18 in.Bottom 18 in.Left 18 in. <br />Note:  Please refer to the tech guide for listed maximum static pressures <br />  <br />4 Ton <br />•All units are manufactured at an ISO 9001 registered facility and each <br />rooftop is completely computer-run tested prior to shipment. <br />Unit Features <br />•Single Stage Cooling <br />•70 MBH Two Stage Input Low Heat Aluminized Gas <br />•Unit Cabinet Constructed of Powder Painted Steel, Certified At 750 Hours <br />Salt Spray Test (ASTM B-117 Standards) <br />•Either supply and/or return can be field converted from vertical to horizontal <br />configuration without cutting panels. <br />•Full perimeter base rails with built in rigging capabilities <br />•Scroll Compressors <br />•Enthalpy Economizer (Downflow only) (with Barometric Relief) with <br />Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC <br />2015, California Title 24, AMCA 511) <br />•High Static Belt Drive Blower <br />•Solid Core Liquid Line Filter Driers <br />•Unit Ships with 2" Throwaway Filters <br />•Replacement Filters: 4 - (16" x 16"). Unit accepts 2" or 4" wide filters. <br />•Single Point Power Connection <br />•Short Circuit Current: 5kA RMS Symmetrical <br />•E-Fin Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin <br />Evaporator Coil <br />Standard Unit Controller <br />•Smart Equipment Control Board <br />•On-Board Diagnostic and Fault Code display <br />•An Integrated Low-Ambient Control, Anti-Short Cycle Protection, Lead-Lag, <br />Fan On and Fan off Delays, Low Voltage Protection, Allows all units to <br />operate in the cooling mode down to 0 °F outdoor ambient without additional <br />components or intervention. <br />•Safety Monitoring - Monitors the high and low-pressure switches, the <br />freezestats, the gas valve, if applicable, and the temperature limit switch on <br />gas and electric heat units. The unit control board will alarm on ignition <br />failures, safety lockouts and repeated limit switch trips. <br />BAS Controller <br />•Smart Equipment Controller including Discharge Air, Return Air, and Outdoor <br />Air Temperature Sensors. BACNet MS/TP, Modbus and N2 communication <br />card. <br />Warranty <br />•One (1) Year Limited Warranty on the Complete Unit <br />•Five (5) Year Warranty - Compressors <br />•Ten (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers <br />•Three (3) Year Warranty - E-coat Outdoor Coil <br />  <br />Information is subject to change without notice. Check local codes.Printed 01/31/2023 <br />  <br />York® Sun™ Core 3-12.5 Ton <br />Package <br />Single Package R-410A Air Conditioner <br />Page: 8 <br />Project Name:  WF 104497 Santa Ana, CA - Rev 1 Unit Model #:  ZYG05D2C1BB1C113A4 <br />Quantity:   2  Tag #: RTU-2 & 3 System:    ZYG05D2C1BB1C113A4 <br />   <br />3925 S Bristol <br />St-HVAC12/23/2024