Laserfiche WebLink
MECHANICAL DATA <br />Dimensions (W × H × D)37.5 cm × 49.5 cm × 16.8 cm (14.75" × 19.5" × 6.63"). <br />Height is 53.5 cm (21.06”) with mounting brackets. <br />Weight 7.5 kg (16.5 lb) <br />Ambient temperature range -40°C to 46°C (-40°F to 115°F) <br />Cooling Natural convection, plus heat shield <br />Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction <br />Wire sizes <br />• 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors <br />• 60 A breaker branch input: 4 to 1/0 AWG copper conductors <br />• Main lug combined output: 10 to 2/0 AWG copper conductors <br />• Neutral and ground: 14 to 1/0 copper conductors <br />• Always follow local code requirements for conductor sizing <br />Communication (in-premise connectivity)Built-in CTRL board for wired communication with the IQ Battery 5P and the IQ System Controller <br />3/3G. Integrated power line communication for IQ Series Microinverters. <br />Altitude Up to 2,600 meters (8,530 feet) <br />COMMUNICATION INTERFACES <br />Integrated Wi-Fi 802.11b/g/n (dual band 2.4 GHz/5 GHz) for connecting the Enphase Cloud through the internet. <br />Wi-Fi range (recommended) 10 m (32.8 feet) <br />Bluetooth BLE4.2, 10 m range to configure Wi-Fi SSID <br />Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) for connecting to the <br />Enphase Cloud through the internet. <br />Cellular/Mobile Connect CELLMODEM-M1-06-SP-05 or CELLMODEM-M1-06-AT-05 (included with the IQ Combiner 5C) <br />Digital I/O Digital input/output for grid operator control <br />USB 2.0 Mobile Connect, COMMS-KIT-01 for IQ Battery 3/3T/10/10T, COMMS-KIT-02 for IQ Battery 5P <br />Access point (AP) mode For connection between the IQ Gateway and a mobile device running the Enphase Installer App <br />Metering ports Up to two Consumption CTs, one IQ Battery CT, and one Production CT <br />Power line communication 90–110 kHz <br />Web API See https://developer-v4.enphase.com <br />Local API See Guide for local API at <br />https://enphase.com/download/accessing-iq-gateway-local-apis-or-local-ui-token-based-authentication <br />COMPLIANCE <br />IQ Combiner with IQ Gateway <br />UL 1741, CAN/CSA C22.2 No. 107.1, Title 47 CFR, Part 15, Class B, ICES 003, NOM-208-SCFI-2016, <br />UL 60601-1/CANCSA 22.2 No. 61010-1, IEEE 1547: 2018 (UL 1741-SB, 3rd Ed.), IEEE 2030.5/CSIP <br />Compliant, Production metering: ANSI C12.20 accuracy class 0.5 (PV production) <br />COMPATIBILITY <br />PV Microinverters IQ6, IQ7, and IQ8 Series Microinverters <br />COMMS-KIT-01 2 <br />IQ System Controller EP200G101-M240US00 <br />IQ System Controller 2 EP200G101-M240US01 <br />IQ Battery ENCHARGE-3-1P-NA, ENCHARGE-10-1P-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-1P-NA <br />COMMS-KIT-02 3 <br />IQ System Controller 3 SC200D111C240US01, SC200G111C240US01 <br />IQ Battery IQBATTERY-5P-1P-NA <br />2 For information about IQ Combiner 5/5C compatibility with the 2nd-generation batteries, refer to the compatibility matrix at <br />https://enphase.com/download/compatibility-matrix. <br />3 IQ Combiner 5/5C comes pre-equipped with COMMS-KIT-02. IQC-5-5C-DSH-00007-4.0-EN-US-2024-06-13 <br />Mobile Connect <br />4G-based LTE-M1 cellular modem with a 5-year <br />data plan <br />(CELLMODEM-M1-06-SP-05 for Sprint and <br />CELLMODEM-M1-06-AT-05 for AT&T) <br />Circuit breakers <br />BRK-10A-2-240V Circuit breaker, 2-pole, 10 A, Eaton BR210 <br />BRK-15A-2-240V Circuit breaker, 2-pole, 15 A, Eaton BR215 <br />BRK-20A-2P-240V Circuit breaker, 2-pole, 20 A, Eaton BR220 <br />BRK-15A-2P-240V-B Circuit breaker, 2-pole, 15 A, Eaton BR215B <br />with hold-down kit support <br />BRK-20A-2P-240V-B Circuit breaker, 2-pole, 20 A, Eaton <br />BR220B with hold-down kit support <br />CT-200-SOLID <br />200 A revenue-grade solid core Production CT <br />with <0.5% error rate (replacement SKU) <br />CT-200-CLAMP <br />200 A clamp-style consumption and battery <br />metering CT with <2.5% error rate (replacement <br />SKU) <br />310 W Carriage Dr Unit# <br />B11/18/2024