My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3009 S Daimler St - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Daimler St
>
3009 S Daimler St
>
3009 S Daimler St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 5:31:35 AM
Creation date
6/6/2025 1:18:24 PM
Metadata
Fields
Template:
Plan
Permit Number
20183770
40139420
101120498
Full Address
3009 S Daimler St
Street Number
3009
Street Direction
S
Street Name
Daimler
Street Suffix
St
Text box
ID:
1
Creator:
Import Agent
Created:
6/6/2025 1:18 PM
Modified:
6/6/2025 9:22 AM
Text:
www.hilti.com
ID:
2
Creator:
Import Agent
Created:
6/6/2025 1:18 PM
Modified:
6/6/2025 9:22 AM
ID:
3
Creator:
Import Agent
Created:
6/6/2025 1:18 PM
Modified:
6/6/2025 9:22 AM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
182
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
www.hilti.com <br />Hilti PROFIS Engineering 3.1.1 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />1 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />Concrete - Jul 22, 2024 <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />1 <br />7/22/2024 <br />Specifier's comments: <br />1 Input data <br /> Anchor type and diameter: Kwik Bolt TZ2 - CS 1/2 (1 1/2) hnom1 <br /> Item number: 2210254 KB-TZ2 1/2x3 3/4 <br /> Specification text: Hilti KB-TZ2 stud anchor with 2 in embedment, <br /> 1/2 (1 1/2) hnom1, Carbon steel, installation <br /> per ESR-4266 <br /> Effective embedment depth: hef,act = 1.500 in., hnom = 2.000 in. <br /> Material: Carbon Steel <br /> Evaluation Service Report: ESR-4266 <br /> Issued I Valid: 12/1/2023 | 12/1/2025 <br /> Proof: Design Method ACI 318-19 / Mech <br /> Stand-off installation: <br /> Profile: <br /> Base material: cracked concrete, 2500, fc' = 2,500 psi; h = 5.000 in. <br /> Installation: hammer drilled hole, Installation condition: Dry <br /> Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present <br /> edge reinforcement: none or < No. 4 bar <br /> Seismic loads (cat. C, D, E, or F) Tension load: yes (17.10.5.3 (d)) <br /> Shear load: yes (17.10.6.3 (c)) <br />3009 S Daimler St <br />11/18/2024
The URL can be used to link to this page
Your browser does not support the video tag.