Laserfiche WebLink
www.hilti.com <br />Hilti PROFIS Engineering 3.1.1 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />6 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />Concrete - Jul 22, 2024 <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />6 <br />7/22/2024 <br />4.2 Pryout Strength <br />Vcp = kcp [(ANc <br />ANc0)y ed,N y c,N y cp,N Nb ] ACI 318-19 Eq. (17.7.3.1a) <br />f Vcp ³ Vua ACI 318-19 Table 17.5.2 <br />ANc see ACI 318-19, Section 17.6.2.1, Fig. R 17.6.2.1(b) <br />ANc0 = 9 h2 <br />ef ACI 318-19 Eq. (17.6.2.1.4) <br />y ed,N = 0.7 + 0.3 (ca,min <br />1.5hef)£ 1.0 ACI 318-19 Eq. (17.6.2.4.1b) <br />y cp,N = MAX(ca,min <br />cac <br />, 1.5hef <br />cac )£ 1.0 ACI 318-19 Eq. (17.6.2.6.1b) <br />Nb = kc l a √f' <br />c h1.5 <br />ef ACI 318-19 Eq. (17.6.2.2.1) <br />Variables <br />kcp hef [in.]ca,min [in.]y c,N <br />1 1.500 ∞1.000 <br />cac [in.]kc l a f' <br />c [psi] <br />8.000 24 1.000 2,500 <br />Calculations <br />ANc [in.2]ANc0 [in.2]y ed,N y cp,N Nb [lb] <br />20.25 20.25 1.000 1.000 2,205 <br />Results <br />Vcp [lb]f concrete f seismic f nonductile f Vcp [lb]Vua [lb] <br />2,205 0.700 1.000 1.000 1,543 216 <br />5 Combined tension and shear loads, per ACI 318-19 section 17.8 <br />bN bV z Utilization bN,V [%]Status <br />0.538 0.140 5/3 40 OK <br />bNV = bz <br />N + bz <br />V <= 1 <br />3009 S Daimler St <br />11/18/2024