Laserfiche WebLink
1L21-1-3-5 <br />16 <br />2 <br />2 <br />39 <br />39 <br />4 <br />4 <br />4 <br />4 <br />39 <br />32 <br />32 <br />14,16 <br />PBW1 <br />PBW4 <br />1 <br />3 <br />TYP <br />4 <br />TYP <br />2 <br />6 <br />TYP <br />16 <br />8 <br />PBW21 <br />PBW31 <br />1 3 5 1 3 5 7 9 11 7 <br />9 <br />11 <br />7 <br />13 <br />13 <br />9 <br />1L21-7-9-11 9 10 <br />1L21-13 <br />1L21-15,17 <br />1L21-19,21 <br />1L21-41,43 <br />1L21-27,291L21-31,331L21-35,37 <br />1L21-2,4,6 <br />1L21-8 <br />1L21-10,1211 <br />J <br />1L21-39 <br />1L21-23-251L21-16 <br />1L21-18,20,22 <br />12 <br />1L21-24 <br />7 <br />7 <br />HM3-37,39,41 <br />1L22-2 <br />8 <br />1L22-6,8 <br />1L22-4 <br />J <br />1L22-10 <br />23 25 <br />1L21-261L21-281L21-30 <br />1L22-1,3,51L22-7,9,11 <br />1L22-131L22-18 <br />5 <br />TYP <br />1L22-12-14,16 <br />1L22-20 <br />1L22-22,24 <br />1L22-32 1L22-26,28,301L22-34,36,381L22-40,42,441L22-46,48,50 <br />9 <br />PBW <br />E6.1 TYP <br />12 <br />1L21-32 <br />17 <br />15 <br />1L22-15-17 9 <br />14 <br />TYP <br />15 <br />TYP <br />1L21-45 <br />1L22-43 <br />16 <br />17 <br />1 <br />2 <br />3 <br />4 <br />D E <br />LAB POWER PLAN <br />SCALE: 1/4"=1'-0"_XREFA <br />POWER KEYNOTES <br />1.PROVIDE 26FT LONG, 225A-120/208V-3PH-4W OVERHEAD PLUG-IN BUSWAY WITH <br />COPPER BUSSING, ALL REQUIRED ACCESSORIES, MOUNTING HARDWARE, BUS <br />CONNECTORS, END FEED UNITS, LABOR, TESTING ETC. NECESSARY TO PROVIDE A <br />COMPLETE, OPERABLE, AND CODE COMPLIANT SYSTEM. PROVIDE SUPPORTS <br />EVERY 4FT AND SEISMIC BRACING AS REQUIRED. COORDINATE WITH STRUCTURAL. <br />MOUNT BOTTOM OF BUSWAY AT 10 FT AFF OR AS DIRECTED BY EDWARDS. VERIFY <br />PRIOR TO INSTALL. PROVIDE PLUG-IN UNITS TO MATCH EQUIPMENT. PROVIDE <br />SPARE UNITS AS DIRECTED BY EDWARDS. PROVIDE STARLINE T3 SERIES OR EQUAL <br />2.PROVIDE 40FT LONG, 500A-120/208V-3PH-4W OVERHEAD PLUG-IN BUSWAY WITH <br />INTERNAL GROUND BUS, COPPER BUSSING, ALL REQUIRED ACCESSORIES, <br />MOUNTING HARDWARE, BUS CONNECTORS, END FEED UNITS, LABOR, TESTING ETC. <br />NECESSARY TO PROVIDE A COMPLETE, OPERABLE, AND CODE COMPLIANT <br />SYSTEM. PROVIDE SUPPORTS EVERY 4 FT AND SEISMIC BRACING AS REQUIRED. <br />COORDINATE WITH STRUCTURAL. MOUNT BOTTOM OF BUSWAY AT 10FT AFF OR AS <br />DIRECTED BY EDWARDS. VERIFY PRIOR TO INSTALL. PROVIDE PLUG-IN UNITS TO <br />MATCH EQUIPMENT. PROVIDE SPARE UNITS AS DIRECTED BY EDWARDS. PROVIDE <br />STARLINE T5 SERIES OR EQUAL. <br />3.PROVIDE DUAL-SERVICE (POWER AND DATA) WALL MOUNTED RACEWAY WITH <br />20A-125V DUPLEX RECEPTACLES AND DATA OUTLETS ON 6 FT CENTERS. FIELD <br />VERIFY LENGTHS AND ADJUST AS NECESSARY. PROVIDE LEGRAND ALUMINUM <br />ALA4800 OR EQUAL. MOUNT AT 24" AFF OR AS DIRECTED BY EDWARDS. <br />RECEPTACLES SHALL BE ON ALTERNATING CIRCUITS WITH A TARGET OF 2 <br />RECEPTACLES PER CIRCUIT. PROVIDE 1"CO FOR EVERY (3) DATA OUTLETS <br />STUBBED 6" ABOVE ACCESSIBLE CEILING SPACE FOR DATA CABLES. VERIFY <br />QUANTITIES, INTERVALS, AND LOCATIONS WITH EDWARDS DATA CONTRACTOR. <br />PROVIDE ALL REQUIRED CONDUIT, CONDUCTORS, CONNECTORS, ACCESSORIES, <br />MOUNTING HARDWARE, ETC. NECESSARY TO PROVIDE A COMPLETE, OPERABLE, <br />AND CODE COMPLIANT SYSTEM. VERIFY EXACT LOCATION AND REQUIREMENTS <br />PRIOR TO INSTALL AND ADJUST AS NECESSARY. <br />4.PROVIDE SPECIAL RECEPTACLE IN WALL MOUNTED RACEWAY FOR SPECIFIC <br />EQUIPMENT. VERIFY DIMENSION WITH EDWARDS. PROVIDE DEDICATED CIRCUIT AS <br />INDICATED. VERIFY RECEPTACLE CONFIGURATION AND EXACT LOCATION PRIOR TO <br />INSTALL AND ADJUST AS NECESSARY. <br />5.CONNECT TO EQUIPMENT AS REQUIRED. VERIFY EXACT LOCATION AND <br />REQUIREMENTS PRIOR TO INSTALL AND ADJUST AS NECESSARY. <br />6.PROVIDE LARGE, DUAL SERVICE, ALUMINUM POWER POLE WITH POWER AND DATA <br />OUTLETS INDICATED. PROVIDE POLE LENGTH AND ALL INTERNAL AND EXTERNAL <br />MOUNTING HARDWARE. LOCATE POWER POLES 10" FROM WALLS. POWER POLES <br />SHALL NOT BE SUPPORTED OR ATTACHED TO WALL. PROVIDE LEGRAND NP8000 OR <br />EQUAL. <br />7.FOR EQUIPMENT CONTROL POWER. VERIFY EXACT LOCATION AND REQUIREMENTS <br />PRIOR TO INSTALL AND ADJUST AS NECESSARY. <br />8.PROVIDE CONDUIT AND BOXES PER EDWARDS AND BUILDING STANDARD FOR CARD <br />READER. <br />9.PROVIDE A SEPARATE NEUTRAL FOR EACH CIRCUIT. <br />10.PROVIDE #10 AWG CIRCUIT CONDUCTORS TO RECEPTACLES IN WALL MOUNTED <br />RACEWAY. <br />11.PROVIDE 2#4-1#8G-1"C. EXTEND SAME FROM DISCONNECT TO EQUIPMENT AS <br />REQUIRED. <br />12.PROVIDE NEMA L21-30 RECEPTACLE. CONNECT TO EQUIPMENT AS REQUIRED. <br />VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO INSTALL AND ADJUST AS <br />NECESSARY. <br />13.NEW ELECTRICAL EQUIPMENT SHALL FIT IN ALLOTTED SPACE WITH EQUIPMENT <br />AND CODE REQUIRED CLEARANCES. CONTRACTOR SHALL COORDINATE <br />EQUIPMENT DIMENSIONS WITH FIELD CONDITIONS PRIOR TO BID. VERIFY EXACT <br />LOCATIONS IN FIELD AND WITH EDWARDS. <br />14.INDICATES CODE REQUIRED CLEARANCE. <br />15.MAINTAIN MANUFACTURER'S REQUIRED CLEARANCE FROM WALLS AND OTHER <br />EQUIPMENT. <br />16.PROVIDE 20A-125V GFCI DUPLEX RECEPTACLE PER 210.63(B)(2). RECEPTACLE <br />SHALL NOT BE CONNECTED TO THE LOAD SIDE OF THE EQUIPMENT'S BRANCH <br />CIRCUIT DISCONNECTING MEANS. <br />17.AREA FOR FUTURE PANELS. KEEP CLEAR FROM FLOOR TO CEILING. DO NOT <br />INSTALL EQUIPMENT IN THIS AREA WITHOUT PRIOR APPROVAL FROM EDWARDS. <br />18.DISTRIBUTION BOARD SHALL NOT BE WIDER THAN 6FT. <br /># <br />SEE SPECIFICATIONS, GENERAL NOTES, SYMBOLS, AND ASSOCIATED REQUIREMENTS. <br />CONTRACTOR SHALL THOROUGHLY REVIEW ALL SPECIFICATIONS, NOTES AND <br />SYMBOLS AND INCLUDE ALL REQUIREMENTS IN HIS BID. VERIFY ALL LOCATIONS AND <br />REQUIREMENTS PRIOR TO INSTALL. <br />REMARKSNO.DATE <br />ar <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br />in <br />t <br />e <br />r <br />i <br />o <br />r <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />pl <br />a <br />n <br />n <br />i <br />n <br />g <br />17 <br />8 <br />8 <br />0 <br /> <br />S <br />k <br />y <br /> <br />P <br />a <br />r <br />k <br /> <br />C <br />i <br />r <br />c <br />l <br />e <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />2 <br />3 <br />0 <br /> <br />- <br /> <br />I <br />r <br />v <br />i <br />n <br />e <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />1 <br />4 <br />t <br />e <br />l <br /> <br />9 <br />4 <br />9 <br />. <br />5 <br />5 <br />3 <br />. <br />8 <br />9 <br />0 <br />0 <br />Ed <br />w <br />a <br />r <br />d <br />s <br />DA <br />I <br />M <br />L <br />E <br />R <br /> <br />A <br />C <br />P <br />L <br />30 <br />0 <br />9 <br /> <br />D <br />A <br />I <br />M <br />L <br />E <br />R <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />23 <br />2 <br />7 <br />6 <br /> <br />S <br />O <br />U <br />T <br />H <br /> <br />P <br />O <br />I <br />N <br />T <br />E <br /> <br />D <br />R <br />. <br />, <br /> <br />U <br />N <br />I <br />T <br />1 <br />0 <br />2 <br />, <br />LA <br />G <br />U <br />N <br />A <br /> <br />H <br />I <br />L <br />L <br />S <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />5 <br />3 <br />O: <br /> <br />9 <br />4 <br />9 <br />- <br />4 <br />1 <br />9 <br />- <br />9 <br />9 <br />0 <br />8 <br /> <br />F <br />: <br /> <br />9 <br />4 <br />9 <br />- <br />4 <br />1 <br />9 <br />- <br />9 <br />8 <br />7 <br />0 <br />E4.1 <br />LAB POWER PLAN <br />LOW VOLTAGE CONDUIT NOTE <br />ALL LOW VOLTAGE DATA/COMM/CONTROL CONDUITS SHALL BE FACTORY COATED <br />BLUE. PROVIDE SAMPLE TO EDWARDS FOR APPROVAL PRIOR TO ORDERING. <br />VERIFY RECEPTACLE TYPE WITH EQUIPMENT PRIOR TO INSTALL AND <br />ADJUST AS NECESSARY. <br />PROVIDE PERMANENT LABEL ON EACH DEVICE INDICATING PANEL <br />AND CIRCUIT NUMBER PER EDWARDS STANDARDS. <br />ALL 120V CIRCUITS SHALL INCLUDE A DEDICATED NEUTRAL. <br />MULTI-WIRE BRANCH CIRCUITS ARE NOT ALLOWED. <br />ALL 120V RECEPTACLES SHALL BE RATED 20A. PROVIDE NEMA 5-20R. <br />UPDATE AND PROVIDE TYPEWRITTEN PANEL CARDS FOR ALL PANELS <br />AFFECTED BY THIS WORK. SUBMIT PANEL SCHEDULES TO EDWARDS <br />AND ENGINEER FOR REVIEW PRIOR TO POSTING NEW SCHEDULES AT <br />PANELS. <br />ALL SPARE CIRCUIT BREAKERS SHALL BE LOCKED OUT / TAGGED OUT <br />OR LEFT IN THE OFF/OPEN POSITION AS DIRECTED BY EDWARDS. <br />PROVIDE GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL <br />ON RECEPTACLES PER 210.8(B) AND SPECIFICALLY WITHIN 6FT FROM SINKS AND <br />DAMP AND WET LOCATIONS. VERIFY IN FIELD WITH EDWARDS. <br />T-DBL2 <br />DBL2 <br />ALL SWITCHBOARDS, SWITCHGEAR, PANELBOARDS, AND MOTOR CONTROL <br />CENTERS SHALL BE LOCATED IN DEDICATED SPACES AND PROTECTED FROM <br />DAMAGE PER 110.26(E)(1) FOR INDOOR OR 110.26(E)(2) FOR OUTDOOR. <br />13 1 <br />1 <br />1 <br />HM3 <br />1L21 <br />1L22 <br />1 <br />1 <br />1111 <br />11 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />11 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />111 <br />1 <br />11 <br />1 <br />1 <br />11 <br />1 <br />18 <br />3009 S Daimler St <br />11/18/2024