Laserfiche WebLink
15 Bottom plate to joist, rim joist, band joist or blocking (at <br />braced wall panels) <br />3-16d box (31/2″ × 0.135″); or <br />2-16d common (31/2″ × 0.162″); or <br />4-3” x 0.131 nails <br />16 Top or bottom plate to stud <br />4-8d box (2 ½” x 0.113”); or <br />3-16d box (31/2″ × 0.135″); or <br />4-8d common (21/2″ × 0.131″); or <br />4-10d box (3” x 0.128”); or <br />4-3” x 0.131 nails <br />3-16d box (3 ½” x 0.135”); or <br />2-16d common (3 ½” x 0.162”); or <br />3-10d box (3”x 0.128”); or <br />3-3” x 0.131 nails <br />17 <br />18 <br />Top plates, laps at corners and intersections <br />1″ brace to each stud and plate <br />3-10d box (3” x 0.128”); or <br />2 –16d common (3 ½” x 0.162”): or <br />3-3” x 0.131 nails <br />3-8d box (21/2″ × 0.113″); or <br />2-8d common (2 ½”x 0.131”); or <br />2010d box (3” x 0.128”); or <br />2 staples 1 3/4″ × <br />19 1″ × 6″ sheathing to each bearing <br />3-8d box (21/2″ × 0.113″); or <br />2-8d common (2 ½” x 0.131”); or <br />2-10d box (3” x 0.128”); or <br />2 staples, 1” crown, 16 ga., 1 3/4″ long <br />3-8d box (21/2″ × 0.113″); or <br />3-8d common (2 ½” x. 0.131”); or <br />3-10d box (3” x 0.128”); or <br />3 staples 1” crown, 16 ga., 1 ¾” long <br />20 1″ × 8″ and wider sheathing to each bearing Wider than 1” x 8” <br />4-8d box (2 ½” x 0.113”); or <br />3-8d common (2 ½” x 0.131”); or <br />3-10d common (3” x 0.128”); or <br />4 staples, 1” crown, 16 ga., 13/4″ long <br />Floor <br />21 Joist to sill, top plate or girder <br />22 Rim joist, band joist or blocking to sill or top plate <br />(roof application also) <br />23 <br />24 <br />25 <br />26 <br />1″ × 6″ subfloor or less to each joist <br />2″ subfloor to joist or girder <br />2″ planks (plank & beam - floor & roof) <br />Band or rim joist to joist <br />4-8d box (21/2″ × 0.113″); or <br />3-8d common (2 ½” x 0.131”); or <br />3-10d box (3”x 0.128”); or <br />3-3” x 0131” nails <br />8d box (21/2″ × 0.113″) <br />8d common (2 ½” x 0.131”); or <br />10d box (3” x 0.128”); or <br />3” x 0.131” nails <br />3-8d box (21/2″ × 0.113″); or <br />2-8d common (2 ½” x 0.131”); or <br />3-10d box (3” x 0.128”); or <br />2 staples, 1” crown, 16 ga., 1 3/4″ long <br />3-16d box (3 ½” x 0.135”) <br />2-16d common (3 ½ ” x 0.162”) <br />3-16d box (31/2″ × 0.135″); or <br />2-16d common (3 ½” x 0.162”) <br />3-16d common (3 ½” x 0.162”) <br />4-10 box (3” x 0.128”), or <br />4-3” x 0.131” nails, or <br />4-3” x 14 ga. staples, 7/16” crown <br />20d common (4” x 0.192”); or <br />27 Built-up girders and beams, 2-inch lumber layers <br />10d box (3” x 0.128”); or <br />3” x 0.131” nails <br />And: <br />2-20d common (4” x 0.192J; or <br />3-10d box(3 ½” x 0.128”); or <br />3-3” x 0.131” nails <br />28 <br />29 <br />Ledger strip supporting joists or rafters <br />Bridging to joist <br />4-16d box (3 ½” x 0.135”); or <br />3-16d common (31/2″ × 0.162″); or <br />4-10d box (3” x 0.128”); or <br />4-3” x 0.131 nails <br />2-10d (3” x 0.128”), or 2-8d common <br />(2 ½” x 0.131”; or 2- 3” x 0.131”) nails <br />Face nail at ends and at each splice <br />At each joist or rafter, face nail <br />Each end, toe nail <br />Face nail <br />3 each 16” o.c. face nail <br />2 each 16” o.c. face nail <br />4 each 16” o.c. face nail <br />Toe nail <br />End nail <br />Face nail <br />Face nail <br />Face nail <br />Toe nail <br />4” o.c. toe nail <br />6” o.c. toe nail <br />Face nail <br />Blind or face nail <br />At each bearing <br />End nail <br />Nail each layer as follows: 32” o.c. at top and <br />bottom and staggered. <br />24” o.c. face nail at top and bottom staggered on <br />opposite sides. <br />ITEM <br />Roof <br />1 <br />RESIDENTIAL NAILING SCHEDULE <br />TABLE R602.3(1) FASTENER SCHEDULE FOR STRUCTURAL MEMBERS <br />DESCRIPTION OF BUILDING ELEMENTS NUMBER AND TYPE OF <br />FASTENERa, b, c <br />Blocking between joists or rafters to top plate, toe nail <br />2 <br />3 <br />4 <br />5 <br />6 <br />Ceiling joists to plate, toe nail <br />Ceiling joists not attached to parallel rafter, laps over <br />partitions, face (see Sections R802.3.2, R802.3.2 and <br />Table R802.5.1(9)) <br />Ceiling joist attached to parallel rafter (heel joint) <br />(see Sections R802.3.1 and R802.3.2 and Table <br />R802.5.1(9)) <br />Collar tie to rafter, face nail or 11/4″ × 20 gage ridge <br />strap to rafter <br />Rafter or roof truss to plate <br />4-8d box (2 ½ x 0.113”)or <br />3-8d (21/2″ × 0.113″); or <br />3-10d box (3”x0.128”);or <br />3-3”x0.131” nails <br />4-8d box (2 ½ x 0.113”)or <br />3-8d (21/2″ × 0.113″); or <br />3-10d box (3”x0.128”);or <br />3-3”x0.131” nails <br />4-10d box (3”x0.128”);or <br />3-16d common (3 ½” x 0.162”);or <br />4-3”x0.131” nails <br />Table R802.5.1(9) <br />4-10d box (3”x0.128”); or <br />3-10d common (3″ × 0.148″); or <br />4-3”x0.131 nails <br />3-16d box nails (31/2″ × 0.135″) or <br />3-10d common nails (3″ × 0.148″); or <br />4-10d box (3”x0.128”); or <br />4-3”x0.131” nails <br />7 Roof rafters to ridge, valley or hip rafters or roof rafter to <br />minimum 2” ridge beam <br />4-16d (31/2″ × 0.135″); or <br />3-10d common (3″ × 0.148″); or <br />4-10d box (3”x0.128”); or <br />4-3” x 0.131 nails <br />3-16d box (31/2″ × 0.135″); or <br />3-16d common (31/2″ × 0.148″); or <br />3-10d box (3”x0.128”); or <br />3-3” x 0.131 nails <br />Wall <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />16d common (3 ½ ″ × 0.162″) <br />Stud to stud (not at braced wall panels)l <br />Stud to stud and abutting studs at intersecting wall <br />corners (at braced wall panels) <br />Built-up header (2” to 2” header with 1/2″ spacer <br />Continuous header to stud <br />Top plate to top plate <br />Double top plate splice <br />10d box (3” x 0.128”); or <br />3”x 0.131” nails <br />16d box (31/2″ × 0.135″); or <br />3” x 0.131” nails <br />16d common (3 ½” x 0.162”) <br />16d common (31/2″ × 0.162″) <br />16d box (3 ½” x 0.135”) <br />5-8d box (21/2″ × 0.113″); or <br />4-8d common (2 ½”x 0.131”); or <br />4-10d box (3” x 0.128”) <br />16d common (3 ½” x 0.162”) <br />10d box (3″ × 0.128″); or <br />3” x 0.131” nails <br />8-16d common (31/2″ × 0.162″); or <br />12-16d box (3 ½” x 0.135”); or <br />12-10d box (3” x 0.128”); or <br />12-3” x 0.131 nails <br />14 Bottom plate to joist, rim joist, band joist or blocking (not <br />at braced wall panels) <br />16d common (3 ½” x 0.162”) <br />16d box (3 ½” x 0.135”); or <br />3” x 0.131” nails <br />Toe nail <br />SPACING OF FASTENERS <br />Per joist, toe nail <br />Face nail <br />Face nail <br />Face nail each rafter <br />2 toe nails on one side and 1 toe nail on opposite <br />side of each rafter or trussi <br />Toe nail <br />End nails <br />24″ o. c. face nail <br />16” o. c. face nail <br />12″ o.c. <br />16” o.c. face nail <br />16″ o.c. each edge face nail <br />12” o.c. each edge face nail <br />Toe nail <br />16” o.c. face nail <br />12” o.c. face nail <br />Face nail on each side of end joist (minimum 24” lap <br />splice length each side of end joint) <br />16” o.c. face nail <br />12 “ o.c. face nail <br />MATERIALS <br />30 <br />31 <br />32 <br />3/8" - 1/2" <br />19/32" - 1" <br />11/8" - 11/4" <br />6d common (2" × 0.113") nail (subfloor wall)j <br />8d common (21/2" × 0.131") nail (roof); or RSRS-01(2⅜” x <br />0.113” nail (roof) j <br />8d common nail (21/2" × 0.131"); or RSRS-01; (2⅜” x <br />0.113”) nail (roof)j <br />10d common (3" × 0.148") nail or <br />8d (21/2" × 0.131") deformed nail <br />Other wall sheathing h <br />33 <br />34 <br />35 <br />36 <br />37 <br />38 <br />39 <br />1/2" structural cellulosic <br />fiberboard sheathing <br />25/32" structural cellulosic <br />fiberboard sheathing <br />1/2" gypsum sheathingd <br />5/8" gypsum sheathingd <br />3/4" and less <br />7/8" - 1" <br />11/8" - 11/4" <br />11/2" galvanized roofing nail, 7/16" head diameter or <br />1¼” long 16 ga. Staple with 7/16” or 1” crown <br />13/4" galvanized roofing nail, 7/16" head diameter or <br />1½" long 16 ga. Staple with 7/16” or 1” crown <br />11/2" galvanized roofing nail; staple galvanized, <br />11/2" long; 11/4 screws, Type W or S <br />13/4" galvanized roofing nail; staple galvanized, <br />15/8" long; 1 5/8”screws, Type W or S <br />6d deformed (2" × 0.120") nail or <br />8d common (21/2" × 0.131") nail <br />3 <br />3 <br />7 <br />7 <br />Wood structural panels, combination subfloor underlayment to framing <br />6 <br />8d common (21/2" × 0.131") nail or <br />8d deformed (21/2" × 0.120") nail <br />10d common (3" × 0.148") nail or <br />8d deformed (21/2" × 0.120") nail <br />6 <br />6 <br />6 <br />6 <br />7 <br />7 <br />12 <br />12 <br />12 <br />Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing to framing <br />(see Table R602.3(3) for wood structural panel exterior wall sheathing to wall framing) <br />6 <br />6 <br />6 <br />12f <br />12f <br />12 <br />Edges <br />(inches) i <br />Intermediate supports c, e <br />(inches) <br />FOR SI: 1 INCH = 25.4 MM, 1 FOOT = 304.8 MM, 1 MILE PER HOUR = 0.447 M/S; 1 KSI = 6.895 MPA. <br />a.NAILS ARE SMOOTH-COMMON, BOX OR DEFORMED SHANKS EXCEPT WHERE OTHERWISE STATED. <br />NAILS USED FOR FRAMING AND SHEATHING CONNECTIONS SHALL HAVE MINIMUM AVERAGE BENDING <br />YIELD STRENGTHS AS SHOWN: 80 KSI FOR SHANK DIAMETER OF 0.192 INCH (20D COMMON NAIL), 90 <br />KSI FOR SHANK DIAMETERS LARGER THAN 0.142 INCH BUT NOT LARGER THAN 0.177 INCH, AND 100 KSI <br />FOR SHANK DIAMETERS OF 0.142 INCH OR LESS. <br />b.STAPLES ARE 16 GAGE WIRE AND HAVE A MINIMUM 7/16-INCH ON DIAMETER CROWN WIDTH. <br />c.NAILS SHALL BE SPACED AT NOT MORE THAN 6 INCHES ON CENTER AT ALL SUPPORTS WHERE SPANS <br />ARE 48 INCHES OR GREATER. <br />d.FOUR-FOOT BY 8-FOOT OR 4-FOOT BY 9-FOOT PANELS SHALL BE APPLIED VERTICALLY. <br />e.SPACING OF FASTENERS NOT INCLUDED IN THIS TABLE SHALL BE BASED ON TABLE R602.3(2). <br />f.WHERE THE ULTIMATE DESIGN WIND SPEED IS 130 MPH OR LESS, NAILS FOR WOOD STRUCTURAL <br />PANEL ROOF SHEATHING TO GABLE END WALL FRAMING SHALL BE SPACE 6 INCHES ON CENTER. <br />WHERE THE ULTIMATE WIND SPEED IS GREATER THAN 130 MPH, NAILS FOR ATTACHING PANEL ROOF <br />SHEATHING TO INTERMEDIATE SUPPORTS SHALL BE SPACED 6 INCHES ON CENTER FOR MINIMUM <br />48-INCH DISTANCE FROM RIDGES, EAVES AND GABLE END WALLS; AND 4 INCHES ON CENTER TO <br />GABLE END WALL FRAMING. <br />g.GYPSUM SHEATHING SHALL CONFORM TO ASTM C 1396 AND SHALL BE INSTALLED IN ACCORDANCE <br />WITH GA 253. FIBERBOARD SHEATHING SHALL CONFORM TO ASTM C 208. <br />h.SPACING OF FASTENERS ON FLOOR SHEATHING PANEL EDGES APPLIES TO PANEL EDGE SUPPORTED <br />BY FRAMING MEMBERS AND REQUIRED BLOCKING AND AT FLOOR PERIMETERS ONLY. SPACING OF <br />FASTENERS ON ROOF SHEATHING PANEL EDGES APPLIES TO PANEL EDGES SUPPORTED BY FRAMING <br />MEMBERS AND REQUIRED BLOCKING. BLOCKING OF ROOF AND FLOOR SHEATHING PANEL EDGES <br />PERPENDICULAR TO THE FRAMING MEMBERS NEED NOT BE PROVIDED EXCEPT AS REQUIRED BY <br />OTHER PROVISIONS OF THIS CODE. FLOOR PERIMETER SHALL BE SUPPORTED BY FRAMING MEMBERS <br />OR SOLID BLOCKING. <br />j.WHERE A RAFTER IS FASTENED TO AN ADJACENT PARALLEL CEILING JOIST IN ACCORDANCE WITH <br />THIS SCHEDULE, PROVIDE TWO TOE NAILS ON ONE SIDE OF THE RAFTER AND TOE NAILS FROM THE <br />CEILING JOIST TO TOP PLATE IN ACCORDANCE WITH THIS SCHEDULE. THE TOE NAIL ON THE <br />OPPOSITE SIDE OF THE RAFTER SHALL NOT BE REQUIRED. <br />j.RSRS-01 IS A ROOF SHEATHING RING SHANK NAIL MEETING THE SPECIFICATIONS IN ASTM F1667. <br />·THE FASTENER SCHEDULE PROVIDES MINIMUM NAILING REQUIREMENTS (I.E. SIZE, <br />SPACING) FOR CONNECTING BUILDING ELEMENTS USED IN WOOD FRAMED <br />CONSTRUCTION. FOR WOOD STRUCTURAL PANELS, BOTH EDGE NAILING AND <br />INTERMEDIATE (FIELD) NAILING ARE SPECIFIED. IN ADDITION TO THE NAILING FOR <br />WOOD STRUCTURAL PANELS, FASTENERS ARE SPECIFIED FOR GYPSUM WALL <br />SHEATHING, CELLULOSIC FIBERBOARD WALL SHEATHING AND COMBINATION <br />SUBFLOOR UNDERLAYMENT. <br />GENERAL NOTES <br />1.BUILDING CODE: 2022 CALIFORNIA BUILDING CODE (C.B.C.) <br /> 2022 CALIFORNIA RESIDENTIAL CODE (C.R.C) <br />2.FLOOR LIVE LOAD = N/A <br />3.ROOF LOAD: DL = 15 PSF LL = 20 PSF <br />4.CEILING LOAD:DL = 5 PSF LL = 20 PSF <br />5.WIND DESIGN DATA: <br />a)BASIC WIND SPEED ...............................................110MPH <br />b)WIND IMPORTANT FACTOR, I ...............................1.0 <br />c)OCCUPANCY CATEGORY......................................II <br />d)WIND EXPOSURE ...................................................C <br />6.EARTHQUAKE DESIGN DATA: <br />a)SEISMIC IMPORTANT FACTOR, I .........................1.0 <br />b)SEISMIC DESIGN CATEGORY .............................II <br />c)SITE CLASS............................................................D <br />d)Ss.............................................................................1.329 <br />e)S1 ............................................................................0.473 <br />f)SDS...........................................................................1.063 <br />g)SD1 ..........................................................................NULL <br />h)DESIGN BASE SHEAR.............................................6103# <br />i)Cs..............................................................................0.154 <br />j)RESPONSE MODIFICATION FACTOR....................R=6.5 <br />k)REDUNDANCY FACTOR ........................................ρ=1.3 <br />l)ANALYSIS PROCEDURE .......................................Equivalent Lateral Force Procedure <br />USE LIGHT-FRAMED WALLS SHEATHED WITH WOOD STRUCTURAL PANELS RATED FOR SHEAR <br />RESISTANCE OR STEEL SHEETS <br />7. SOIL REPORT NO : GEO252524LP, DATED: 09/12/2024, BY TMC ENGINEERS INC. <br />STRUCTURAL NOTES AND SPECIFICATIONS <br />FOUNDATION <br />1.FOUNDATION HAVE BEEN DESIGNED USING ALLOWABLE SOIL BEARING CAPACITY OF 1,500 PSF, <br />2.FOUNDATION DESIGN SHALL BE 24" MIN. DEPTH OF FTG BELOW LOWEST ADJACENT FINAL GRADE, AND <br />12" MIN. WIDTH FOR 1 STORY, 15" MIN. WIDTH FOR 2 STORY, BEAR ON FIRM NATIVE OR PROPERLY <br />COMPACTED SOILS. <br />3.FOUNDATION DESIGN IS BASED ON NON-EXPANSIVE SOIL. IF FOUND THAT SOIL EXPANSIVE SO THAT <br />FOOTINGS ARE REDESIGNED PRIOR TO POURING OF CONCRETE FOUNDATIONS. <br />4.EXISTING FOUNDATIONS ARE ASSUMED TO BE IN GOOD CONDITION.CONTRACTOR SHALL NOTIFY THE <br />ENGINEER OF ANY FOUNDATION WITH SIGNIFICANT SETTLEMENT, SEVERE CRACKING OR ANY <br />INDICATION OF STRUCTURAL FAILURE OR DISTRESS OR DEFECT. <br />5.THE CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING, FENCE ENCLOSURES AND PROTECTION <br />LIFE AND PROPERTY UNTIL THE PROJECT IS COMPLETE. <br />6.A DILIGENT SEARCH SHALL BE CONDUCTED BY THE SOIL ENGINEER AND GRADING OR GENERAL <br />CONTRACTOR TO LOCATE CESSPOOLS, SEPTIC TANK ETC, IF FOUND, PROPER ABANDONMENT <br />PROCEDURE SHALL BE CONDUCT AS DIRECTED BY THE SOILS ENGINEER. ABANDONMENT AND/OR <br />COMPACTION REPORT SHALL BE SUBMITTED TO THE CITY BUILDING DEPARTMENT AND ENGINEER <br />REPORT. <br />7.CONTRACTOR SHALL BRACE OR PROTECT FORM LATERAL LOADS FOR THE PIT AND RETAINING WALLS <br />UNTIL ATTACHING SLABS ARE COMPLETELY IN PLACE AND HAVE ATTAINED FULL STRENGTH. NO <br />VERTICAL EXCAVATIONS 4'-0" OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESEND <br />SHALL BE PERMITTED <br />REINFORCING STEEL <br />1.REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO THE REQUIREMENTS OF A.S.T.M. <br />A-615 GRADE 60 FOR BARS LARGER THAN #4, GR.40 FOR #4 OR SMALLER. WELDED WIRE FABRIC SHALL <br />CONFORM TO A.S.T.M. A-82 AND A-185 . LAP 12 INCHES MINIMUM. <br />2.DETAILING, FABRICATION AND ERECTION OF REINFORCING BARS SHALL CONFORM TO THE LATEST <br />EDITION OF A.C.I. <br />3.MANUAL OF STANDARD PRACTICE FOR DETAILING AND REINFORCED CONCRETE STRUCTURES. <br />4.MINIMUM COVER FORECAST IN PLACE CONCRETE SHALL BE AS FOLLOWS: <br />a.POURED AGAIN EARTH 3 INCHES <br />b.POURED AGAIN FORM BELOW GRADE 2 INCHES <br />c.FORMED SLABS 3/4 INCH <br />d.SLAB ON GRADE, TOP COVER 1 INCH <br />e.COLUMN AND BEAM MAIN BARS 1-1/2 INCHES <br />f.WALLS EXPOSED TO WEATHER # 6 AND LARGER 2 INCHES <br />g. WALL EXPOSED TO WEATHER # 5 AND SMALLER 1-1/2 INCHES <br />5.BARS SHALL BE CLEAN OF RUST, GREASE AND OTHER DELETERIOUS MATERIAL THAT MAY AFFECT <br />BOND. <br />6.ALL BEND SHALL BE MADE COLD. <br />7.LAP SPLICE LENGTH SHALL BE 42 BARS DIAMETERS MINIMUM AND SHALL BE STAGGERED. <br />8.DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL HAVE SAME SIZE AS THE VERTICAL <br />REINFORCEMENT, EMBEDMENT OF DOWELS SHALL BE 36 BAR DIAMETER OR 2'-0" MINIMUM UNLESS <br />OTHERWISE SHOWN. DOWELS SHALL BE EQUAL IN SIZE AND SPACING. <br />9.FOR STEM WALLS LONGER THAN 24", PROVIDE #4 VERTICAL BARS @ 24" O.C. <br />10.LANDING - 3 ½" CONC W/ 6X6 10/10 WIRE MESH. <br />11.PROVIDE VERTICAL AND HORIZONTAL REBAR IN FOUNDATION STEM WALL THAT EXCEEDS 24" IN <br />HEIGHT MEASURED FROM TOP OF FOOTING. <br />12.MINIMUM LAP OF MESH SHALL BE NOT LESS THAN THE SPACING OF THE CROSS WIRE PLUS TWO <br />INCHES OR 60 DIA, OR 8 IN. WHICHEVER IS GREATER <br />13.ALL REINFORCING BARS, EMBEDS, ANCHOR BOLTS, HOLDOWNS ETC. SHALL BE SECURED IN PLACE <br />PRIOR TO PLACEMENT OF CONCRETE. <br />14.CODE REQUIRED INSPECTIONS BY JURISDICTION AUTHORITY SHALL BE MADE AN SIGNED OFF PRIOR <br />TO PLACEMENT OF CONCRETE. <br />FRAMING LUMBER <br />1.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR LARCH OF THE FOLLOWING MINIMUM GRADES: <br />a.2X JOIST / RAFTERS NO.2 OR BETTER <br />b.4X POSTS / BEAMS / HEADERS NO.2 OR BETTER <br />c.6X AND 8X POSTS / BEAMS / HEADERS NO.1 OR BETTER <br />d.FLOOR JOIST ABOVE GARAGE TO BE D.F.NO.1 OR BETTER <br />e.STUDS: STUD GRADE (UP TO 9'-0"), NO.2 FOR TALLER THAN 9'-0" <br />f.TOP PLATES & MUD SILLS: CONSTRUCTION GRADE OR BETTER <br />2.WALL SILLS, NAILERS, AND LEDGERS IN CONTACT WITH CONCRETE: PRESERVATIVE TREATED <br />3.STRUCTURE PANELS SHALL BE DOUGLAS FIR CONFORMING TO U.S. PRODUCT STANDARD PS-1-95 CD <br />WITH EXTERIOR GLUE, AND SHALL BEAR THE STAMP OF AN APPROVED FABRICATOR. <br />4.INSTALLATION OF VERTICAL AND HORIZONTAL SHEATHING SHALL FIRST BE APPROVED BY THE <br />INSPECTOR PRIOR TO COVERING. <br />5.NO STRUCTURAL MEMBER SHALL BE CUT OR NOTCHED UNLESS SPECIFICALLY SHOWN ON APPROVED <br />PLANS. <br />6.MAXIMUM MOISTURE CONTENT OF ALL NUMBER SHALL BE 19%. <br />7.BOLT HOLES TO BE NOMINAL DIAMETER OF BLOT PLUS 1/16 INCH UNLESS NOTED OTHERWISE. <br />PROVIDE WASHERS UNDER HEAD AN NUTS OF BOLTS AND LAG SCREWS. <br />8.FRAMING CONNECTION HARDWARE: AS MANUFACTURED BY SIMPSON STRONGTIE CO. OR APPROVED <br />EQUIVALENTS DESIGNATIONS USED. USE NAILS PER ICBO APPROVAL AND AS RECOMMENDED BY <br />SIMPSON FOR EACH DEVICE. <br />9.THE NUMBER OF NAILS CONNECTING LUMBER SHALL NOT BE LESS THAN THE MINIMUM REQUIRED ON <br />2022 CRC R602.3(1) <br />10.ALL NAILS USED ON STRUCTURAL PANELS SHALL BE COMMON NAILS. ALL NAILING TO BE PER CBC 2022 <br />CRC R602.3(1) , UNLESS OTHERWISE NOTED. <br />11.PROVIDE CONTINUOUS EDGE SUPPORT ALONG TOP AND BOTTOM OF 2X14 JOISTS. <br />12.BUILT-UP FRAMING MEMBERS SHALL BE CONNECTED AS FOLLOWS: a. 2-2X 16D AT 12" O.C. <br />STAGGERED TOP AND BOTTOM. b. 3-2X 5/8" DIA. M.B. AT 18" O.C. STAGGERED TOP & BOTTOM. c. 4-2X <br />5/8" DIA. M.B. AT 18" O.C. STAGGERED TOP & BOTTOM. <br />13.PROVIDE DOUBLE JOISTS UNDER PARALLEL PARTITIONS. <br />14.PROVIDE SOLID BLOCKING UNDER ALL NON-PARALLEL PARTITIONS. <br />15.INSTALL LAG BOLTS BY DRILLING LEAD HOLE 65% TO 75% OF SHANK DIAMETER AND FULL DIAMETER <br />FOR SHANK PORTION. <br />16.USE SOAP OR OTHER APPROVED LUBRICANT ON THREADS. INSTALLATION SHALL BE BY TIGHTENING <br />OF SCREW NOT BY HAMMERING. <br />17.TRUSS JOISTS SHOP DRAWINGS SHALL BE PROVIDED BY THE SUPPLIER AND SUBMITTED TO THE <br />BUILDING DEPARTMENT FOR APPROVAL PRIOR TO FABRICATION. SHOP DRAWINGS SHALL BE STAMPED <br />AND WET SIGNED BY A LICENSED ENGINEER. <br />STEEL <br />1.ALL STRUCTURAL AND MISCELLANEOUS STEEL SHALL CONFORM TO A.S.T.M. A-36 AND SHALL BE <br />FABRICATED AND ERECTED IN ACCORDANCE WITH THE A.I.S.C. SPECIFICATIONS FOR THE DESIGN, <br />FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDING, LATEST EDITION. <br />2.PIPE COLUMNS SHALL CONFORM TO A.S.T.M. A-53 GRADE B. <br />3.TUBULAR STEEL SHALL CONFORM TO A.S.T.M. A500 GRADE B. <br />4.BOLTS SHALL CONFORM TO A.S.T.M. A-307 UNLESS NOTED OTHERWISE. <br />5.SHOP DRAWING SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEER AND BUILDING DEPARTMENT <br />FOR REVIEW PRIOR TO FABRICATION. <br />6.FABRICATION SHALL BE DONE IN THE SHOP OF LICENSED FABRICATORS. <br />7.USED ELECTRIC ARC PROCESS WELDING WITH E70XX ELECTRODES. <br />8.ALL WELDING SHALL BE DONE IN THE SHOP OF LICENSED FABRICATOR OR PROVIDE CONTINUOUS <br />SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR. <br />9.WHERE A FILLET WELD SYMBOL IS USED IN THE PLANS WITHOUT INDICATION OF SIZE, THE MINIMUM <br />WELD SIZE AS SPECIFIED IN THE A.I.S.C. MANUAL OF STEEL CONSTRUCTION SHALL BE USED. <br />CONCRETE <br />1.THE MINIMUM COMPRESSIVE STRENGTH OF CONCRETE SHALL BE F'C=2,500 PSI @ 28 DAYS UNLESS <br />OTHERWISE NOTED, WATER_CEMENT RATIO OF 0.45, TYPE V CEMENT. <br />2.AGGREGATES SHALL CONFORM TO A.S.T.M. C33 <br />3.READY-MIXED CONCRETE SHALL BE IN ACCORDANCE WITH REQUIREMENTS OF ASTM C94. <br />4.MAXIMUM SLUMP SHALL BE 5" UNLESS NOTED OTHERWISE. <br />5.CONCRETE SHALL BE MAINTAINED MOIST A MINIMUM OF 10 DAYS AFTER PLACEMENT. <br />6.PRIOR TO PLACING CONCRETE, REINFORCING STEEL AND EMBEDDED ITEMS SHALL WELL SECURED IN <br />PROPER POSITIONS. <br />7.USE TYPE II OR V CEMENT AS REQUIRED AGAINST SULFATE ATTACK. <br />8.ALL BOLT HOLES SHALL BE DRILLED 1/32" TO 1/16" OVERSIZED. <br />9.HOLD-DOWNS SHALL BE RE-TIGHTENED JUST PRIOR TO COVER THE WALL FRAMING. <br />1.ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF THE 2019 CALIFORNIA BUILDING CODES AND <br />ALL AMENDMENTS AND LOCAL, COUNTY, STATE AND FEDERAL REGULATIONS. <br />2.THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK <br />ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO BID AND SIGNING OF CONTRACT. ALL <br />DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT AND ENGINEER AND BE <br />RESOLVED IN WRITING BEFORE PROCEEDING WITH THE WORK. <br />3.GENERAL NOTES AND TYPICAL DETAILS SHALL APPLY TO ALL PARTS OF THE JOB EXCEPT WHERE THEY <br />ARE IN CONFLICT WITH DETAILS AND NOTES ON OTHER DOCUMENTS; THE MORE STRICT CONDITION <br />APPLIES SUBJECT TO REVIEW BY THE ENGINEER. <br />4.ALL INFORMATION SHOWN ON THE PLANS RELATIVE TO EXISTING CONDITION WERE CAREFULLY TAKEN <br />IN THE FIELD BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS ARE IN CONFLICT <br />WITH THE PLANS, THEY SHALL BE REPORTED TO THE ENGINEER SO THAT PROPER CHANGES CAN BE <br />MADE. <br />5.REQUIRED SHOP DRAWINGS SHALL BE SUBMITTED TO THE ENGINEER AND THE BUILDING DEPARTMENT <br />FOR REVIEW. <br />6.MODIFICATION OF STRUCTURAL PLANS AND MATERIAL SUBSTITUTIONS SHALL NOT BE DONE WITHOUT <br />WRITTEN APPROVAL OF THE ENGINEER. <br />7.THE APPROVED PLANS AND SPECIFICATIONS REPRESENT THE FINISH STRUCTURE AND DO NOT INCLUDE <br />THE MOTHODS OF CONSTRUCTION. THE CONTRACTOR SHALL SUPEVISE AND DIRECT THE WORK AND <br />SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION METHODS, MEANS, TECHINQUES, SEQUENCES <br />AND PROCEDURES INCLUDING BUT NOT LIMITED TO SHORING, INSURANCE, FENCING, CONSTRUCTION <br />CANOPY, SCAFFOLDING ETC. FIELD OBSERVATIONS BY THE ENGINEER SHALL NOT BE CONSIDERD AS <br />INSPECTIONS AS REQUIRED BY THE CODE. <br />8.REFER TO THE ARCHITECTURAL PLANS FOR DIMENSIONS, OPENINGS, LAYOUT ETC. <br />BAR SIZE MINIMUM EMBEDMENT *REMARKS <br />#3 3 1/2" <br />#4 OR 1/2" Ø 4 1/4" <br />#5 OR 5/8" Ø 5 1/2" <br />#6 OR 3/4" Ø 6 3/4" <br />DESIGN CRITERIA <br />FASTENER NOTES <br />EPOXY ANCHORS <br />1.EPOXY FOR EPOXY ANCHORS SHALL BE SET-XP BY "SIMPSON STRONG-TIE" (ICC ESR. #2508) <br />2.ANCHORS USED FOR EPOXY ANCHORS SHALL BE ASTM A-307 THREADED RODS UNO. SIZE AND <br />EMBEDMENT SHALL BE AS INDICATED ON PLANS <br />3.ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH THE EPOXY MANUFACTURER'S <br />RECOMMENDATIONS AND THE CURRENT ICC REPORT <br />4.ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH CBC-2011 SECTION 1704 AND IN ACCORDANCE <br />WITH THE SPECIFIC SPECIAL INSPECTION REQUIREMENTS SET FORTH IN THE CORRESPONDING ICC <br />REPORT <br />5.DRILLED HOLES SHALL BE CLEANED OF DUST AND ANY DEBRIS USING NYLON BRUSH AND COMPRESSED <br />AIR OIL, SCALE, AND RUST SHALL BE REMOVED FROM THREADED RODS PRIOR TO INSTALLATION <br />6.UNLESS NOTED OTHERWISE IN THE PLANS, EPOXY ANCHORS SHALL HAVE THE FOLLOWING MINIMUM <br />EMBEDMENT. <br />EXPOSED TO WEATHER <br />1.ALL EXPOSED STEEL MEMBERS SHALL BE COATED WITH A ZINC RICH PRIMER. <br />2.ALL EXTERIOR HANGERS AND OTHER SIMPSON TYPE PRODUCTS SHALL BE GALVANIZED. <br />3.ALL PLYWOOD SHALL BE OF AN EXP. 1 GRADE. <br />FRAMING <br />1.DOUBLE FLOOR JOISTS REQUIRED UNDER PARALLEL BEARING PARTITIONS. <br />2.APPLY CONT. LINE OF GLUE TO FLOOR PANELS AT ALL JOISTS. <br />3.BLOCKINGS ARE REQUIRED AT ALL SHEARWALL PANEL EDGES. <br />4.CONSTRUCT OF PLYWOOD SHEARWALL SHALL BE WITH COMMON NAILS ONLY. <br />8.POWER DRIVEN PINS ARE NOT PERMITTED AT FOUNDATIONS HORIZONTAL <br />9.HOLDDOWN BOLT HOLES AT EACH END OF THE PLYWOOD SHEARWALLS SHALL HAVE TOLERANCE OF NO <br />MORE THAN 1/16". <br />10.ALL POSTS WITH HOLDDOWNS OR UPLIFT STRAPS SHALL HAVE CONTINUOUS EDGE NAILING. <br />11.ANCHOR BOLTS SHALL BE MIN. 5/8" DIA., 7" EMB. INTO CONCRETE, @ 4' OC U.O.N. ON SHEARWALL <br />SCHEDULE, 12" FROM ENDS, 2 MINIMUM PER PLATE, AND WITH 3"X3"X.229" STEEL PLATE WASHERS. BOLTS <br />SHALL EXTEND 5" INTO FOOTING ON TWO POUR SYSTEM (EXTRA LONG BOLTS). PROVIDE MINIMUM EDGE <br />DISTANCE OF 1 7/8" FOR THE 5/8" DIA. ANCHOR BOLTS. <br />12.PLATE WASHERS FOR ALL ANCHOR BOLTS TYPICAL: <br />PLYWOOD SHEATHING: <br />1.SLOPED/FLAT NON-ASSEMBLY ROOF SHEATHING: 15/32" APA RATED SHEATHING EXP 1 WITH A MIN. PANEL <br />INDEX OF 32/16. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE. ROOF SHEATHING RING <br />SHANK #03 (2 1/2" X 0.131") NAIL @ 6" O.C. @ PANEL EDGES & 12" O.C. @ INTERMEDIATE. <br />2.FLOOR/ROOF DECK/DECK SHEATHING: 23/32" APA RATED STURD-I-FLOOR T&G EXP I WITH MIN. SPAN <br />RATING OF 24" O.C. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE. T&G OR BLOCKING <br />REQUIRED ALL EDGES, 10D @ 6" @ PANEL EDGES & 12" @ INTERMEDIATE. <br />3.VERTICAL PLYWOOD SHEATHING: SEE SHEAR WALL SCHEDULE. <br />4.ALL STRUCTURAL RATED PANELS MUST BE STAMPED BY ONE OF THE FOLLOWING APPROVED AGENCIES, <br />APA, PFS/TECO OR PITTSBURG. <br />5.USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING USING ADHESIVES MEETING APA <br />SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN ACCORDANCE WITH MANUFACTURER'S <br />RECOMMENDATIONS. <br />6.AS AN ALTERNATE TO 10D COMMON NAILS, THE FOLLOWING FASTNERS CAN BE USED: GRABBER <br />PLYWOOD SCREWS (ICC-ER-5280), OR SIMPSON STRONG-TIE QUICK DRIVE SCREWS (ICC-ER-1472), MIN 2" <br />LONG @ 6" O.C. B.S., @ 6" O.C. E.S. AND 12" O.C. F.S. <br />GLULAM/PARALLAM/MICROLAM BEAMS <br />1.GLUE LAMINATED BEAM S SHALL BE PER AMERICAN INSTITUTE OF TIMBER CONSTRUCTION 117. <br />CONBINATION SYMBOLS SHALL BE AS FOLLOWS: <br />a)24F-V4 DF/DF FOR SIMPLE BEAMS <br />b)24F-V8 DF/DF FOR CANTILEVERED BEAMS <br />2.PARALLAM BEAMS SHALL BE 2.0E PSL, ICC # ESR-1387 <br />3.MICROLAM BEAMS SHALL BE 2.0E LVL <br />4.LAMINATED BEAMS SHALL BE FABRICATED BY A LICENSED FABRICATOR AND SHALL BE ACCOMPANIED TO <br />THE JOB SITE WITH CERTIFICATE OF FABRICATION. <br />BOLT SIZE (A307)PLATE SIZE (ASTMA-36)MIN. EDGE DISTANCE (IN.) <br /> 5/8" Ø 0.229" x 3" x 3"1 7 8 <br />3/4" Ø 0.229" x 3" x 3"2 1 2 <br />7/8" Ø 5/16" x 3" x 3"2 5 8 <br />1 1/4" Ø 3/8" x 3 1/2" x 3 1/2"3 3 4 <br />SHEET INDEX <br />DEFERRED SUBMITTAL <br />Consultant: <br />Address: <br />Address <br />Phone <br />e-mail <br />AD <br />D <br />R <br />E <br />S <br />S <br />: <br />SHEET NAME <br />DATE <br />DRAWN BY: <br />CHECKED BY: <br />SHEET NUMBER <br />REVISION <br />STAMP <br />PR <br />O <br />J <br />E <br />C <br />T <br />12 <br />/ <br />8 <br />/ <br />2 <br />0 <br />2 <br />4 <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />LP <br />12/08/2024 <br />HP <br /> 2 <br />7 <br />2 <br />6 <br /> <br />S <br />T <br />R <br />A <br />W <br />B <br />E <br />R <br />R <br />Y <br /> <br />L <br />A <br />N <br />E <br />, <br /> <br />U <br />N <br />I <br />T <br /> <br />2 <br />Description Date <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br /> 2 <br />7 <br />2 <br />6 <br /> <br />S <br />T <br />R <br />A <br />W <br />B <br />E <br />R <br />R <br />Y <br /> <br />L <br />A <br />N <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />1ST PC RESPONSE 12/08/241 <br />GENERAL NOTES <br />AND REQUIREMENT <br />SN1 <br />(4) <br />(2) <br />(1) <br />(3) <br />870 <br />(PLF) <br />SHEAR <br />ALLOWABLE <br />220 <br />2022 CALIFORNIA BUILDING CODE (1), (3) <br />SHEAR WALL SCHEDULE <br />PANEL <br />TYPE <br />SHEAR <br />8 d's <br />10 d's <br />@ 2" O.C. <br />8 d's <br />@ 2" O.C. <br />@ 3" O.C. <br />15/32" APA <br />Structural I <br />rated <br />3/8" APA <br />rated <br />10 d's <br />@ 12" O.C. <br />8 d's <br />@ 12" O.C. <br />8 d's <br />@ 12" O.C. <br />8 d's <br />@ 4" O.C. <br />NAILING <br />(COMMON) <br />EDGE <br />8 d's <br />@ 6" O.C. <br />3/8" APA <br />rated <br />rated <br />3/8" APA <br />SHEATHING <br />8 d's <br />@ 12" O.C. <br />@ 12" O.C. <br />8 d's <br />FIELD <br />(COMMON) <br />NAILING <br />STUDS ARE SPACED @ 16" O.C. MAX. UNLESS NOTED OTHERWISE ON PLAN. <br />PERIODIC SPECIAL INSPECTION IS REQUIRED. <br />(4) (2) <br />3 <br />2 <br />1 <br />4 <br />5 <br />(5) <br />(6) <br />USE CLIPS @ 6" O.C. ON SIMPSON STRONG WALL & HARDY FRAME (U.N.O.). <br />@ 4" O.C. <br />@ 6" O.C. <br />@ 3" O.C. <br />@ 2" O.C. <br />@ 16" O.C. <br />@ 12" O.C. <br />@ 8" O.C. <br />@ 6" O.C. <br />@ 5" O.C. <br />@ 24" O.C. <br />@ 16" O.C. <br />@ 12" O.C. <br />@ 10" O.C. <br />@ 6" O.C. <br />SHEATHING PANEL JOINT AND SILL PLATE NAILING SHALL BE STAGGERED IN ALL CASES. <br />PROVIDE 3" NOMINAL OR WIDER FRAMING AT ADJOINING PANEL EDGES WITH NAILS STAGGERED. <br />USE SPACING PER SCHEDULE IF NUMBER OF FRAMING CLIPS ARE NOT SPECIFIED ON FRAMING PLANS. <br />FRAMING CLIPS A35's, <br />LS50's OR LTP5's <br />(5), (6) <br />2 ROWS <br />STAGG. <br />@ 3" O.C. <br />(4) (2) <br />(4) (2) <br />(4) (2) <br />(8) <br />260 <br />320 <br />380 <br />410 <br />490 <br />(7)ALLOWABLE SHEAR ARE FOR STUDS SPACED @ 24" O.C. MAX. <br />(8)SHEATHING CONFORMS TO EITHER DOC PS 1 OR PS 2 STANDARDS. <br />(9)NAILING @ 6" O.C. WHEN STUDS ARE SPACED @ 24" O.C. <br />(9) <br />(7) <br />(7) <br />(7) <br />3/8" APA <br />rated 530 <br />640 (7) <br />(10)FOR DOUBLE SIDED SHEAR PANELS: <br />(10)(10)(10) <br />(10)(10)(10) <br />(10)(10)(10) <br />a. USE HALF THE SPACING OF SILL PLATE FASTENERS STAGGERED FOR TYPE . <br />b. USE ONLY 1/4"Øx6" SDS SCREWS IN SCHEDULE AND WITH HALF THE SPACING, <br /> FOR TYPES & . <br />3 <br />4 5 <br />c. SEE SHEAR TRANSFER DETAIL ON PLAN FOR FRAMING CLIP TYPES AND SPACING, <br /> FOR TYPES , & .3 4 5 <br />SILL PLATE CONNECTION <br />SINKER <br />16d's SCREWS <br />RIM BOARD <br />LSL & DF <br />1/4"Øx6" <br />SDS <br />SCREWS <br />RIM BOARD <br />LVL <br />1/4"Øx6" <br />SDS <br />@ 14" O.C. <br />@ 10" O.C. <br />@ 7" O.C. <br />@ 5" O.C. <br />@ 4" O.C. <br />(10) <br />(10) <br />(10) <br />PRESCRIPTIVE TABLES <br />JOIST <br />SPACING <br />ATTICS WITHOUT STORAGE, <br />LL=10PSF <br />ATTICS WITH STORAGE, <br />LL=20PSF <br />2X4 2X6 2X8 2X10 2X4 2X6 2X8 2X10 <br />12"12'-5"19'-6"25'-8"--9'-10"14'-10"18'-9"22'-11" <br />16"11'-3"17'-8"23'-4"--8'-11"13'-0"16'-6"20'-2" <br />24"9'-10"15'-0"19'-1"23'-3"7'-3"10'-8"13'-6"16'-5" <br />DF #2 CEILING JOISTS, ALLOWABLE SPANS <br />DATA FROM CRC TABLE R802.5.1(1) & R802.5.1(2) ATTIC WITH STORAGE ARE THOSE WHERE THE CLEAR HEIGHT BETWEEN <br />THE CEILING JOIST AND RAFTER IS 42" OR GREATER. ATTICS SHALL BE UNINHABITABLE. CEILING DEAD LOAD SHALL NOT <br />EXCEED 5 PSF. <br />TIE <br />SPACING <br />ROOF PITCH <br />3:12 4:12 5:12 7:12 9:12 <br />SPAN SPAN SPAN SPAN SPAN <br />12'20'28'36'12'20'28'36'12'20'28'36'12'20'28'36'12'20'28'36' <br />12"4 6 8 1 3 5 6 8 3 4 5 6 3 4 4 5 3 3 4 4 <br />16"5 8 10 13 4 6 8 10 3 5 6 8 3 4 5 6 3 4 4 5 <br />24"7 11 15 19 5 8 12 15 4 7 9 12 3 5 7 9 3 4 6 7 <br />RAFTER TIE CONNECTIONS, #16d COMMON NAILS <br />DATA FROM CRC TABLE R802.5.2 VALUES ADJUSTED FOR DF#2 FRAMING. THE NUMBER OF NAILS SPECIFIED IN THE TABLE <br />SHALL BE PROVIDED AT EACH CONNECTION. WHEN FULL-HEIGHT INTERIOR BEARING WALLS OR PURLIN BRACING ARE <br />PROVIDED, RAFTER TIE NAILING MAY BE REDUCED PROPORTIONAL TO THE REDUCTION IN RAFTER SPAN; NO LESS THAN 3 <br />NAILS SHALL BE PROVIDED AT EACH CONNECTION. NO SNOW LOAD <br />JOIST <br />SPACING <br />DL = 10PSF, LL = 40PSF <br />2X6 2X8 2X10 2X12 <br />12"10'-9"14'-2"18'-0"20'-11" <br />16"9'-9"12'-9"15'-7"18'-1" <br />24"8'-3"10'-5"12'-9"14'-9" <br />DF #2 FLOOR JOISTS, ALLOWABLE SPANS <br />DATA FROM CRC TABLE R502.3.1(2) <br />SHEATHING GRADE ALLOWABLE LL(PSF)ROOF FLOOR <br />SPAN <br />RATING <br />FLOOR/R <br />OOF <br />SPAN <br />THICKNE <br />SS <br />SPAN <br />@16"O.C. <br />SPAN <br />@24"'O.C. <br />MAX. SPAN (in.)LOADS (psf) <br />PANEL EDGES WITH T&G <br />JOINTS OR BLOCKING <br />MAX. SPAN (in.) <br />WITH <br />EDGE <br />SUPPOR <br />T <br />WITHOUT <br />EDGE <br />SUPPOR <br />T <br />TOTAL <br />LOAD <br />LIVE <br />LOAD <br />24 <br />0 <br />3 <br />8 100 30 24 20 40 30 0 <br />24 <br />16 <br />7 <br />16 100 40 24 24 50 40 16 <br />32 <br />16 <br />15 <br />32 180 70 32 28 40 30 16 <br />40 <br />20 <br />19 <br />32, 5 <br />8 305 130 40 32 40 30 20 <br />48 <br />24 3/4, 3/4, 0 -175 48 36 45 35 24 <br />PLYWOOD OR OSB FLOOR AND ROOF SHEATHING, ALLOWABLE SPANS <br />DATA FROM CRC TABLE R503.2.1.1(1) SHEATHING PANELS SHALL BE CONTINUOUS OVER TWO OR MORE SPANS AND <br />PERPENDICULAR TO SUPPORTS. FOR 1/2" SHEATHING MAXIMUM SPAN SHALL BE 24". EDGE SUPPORT MAY BE PROVIDED BY <br />TONGUE AND GROOVE EDGES, 2X BLOCKING OR PANEL EDGE CLIPS. <br />SIGNED DATE: 12/8/2024 <br />1 <br />2726 W Strawberry Ln & <br />Unit# 23/17/2025