Laserfiche WebLink
WoodWorks® Shearwalls 2726 Strawberry.wsw Jul. 21, 2024 11:26:22 <br />SHEATHING MATERIALS by WALL GROUP <br />Sheathing Fasteners Apply <br />Grp Surf Material Ratng Thick GU Ply Or Gvtv Size Type RS Eg Fd Bk Notes <br />in in lbs/in in in <br />1 Ext Structural sheath 24/0 3/8 -3 Horz 25000 6d Common N 6 6 Y <br />Legend: <br />Grp – Wall Design Group number, used to reference wall in other tables (created by program) <br />Surf – Exterior or interior surface when applied to exterior wall <br />Ratng – Span rating, see SDPWS Table C4.2.3C <br />Thick – Nominal panel thickness <br />GU - Gypsum underlay thickness <br />Ply – Number of plies (or layers) in construction of plywood sheets <br />Or – Orientation of longer dimension of sheathing panels or lumber planks. Dbl. = Double diagonal. <br />Gvtv – Shear stiffness in lb/in. of depth from SDPWS Tables C4.2.3A-B <br />Type – Fastener type from SDPWS Tables 4.3A-D: <br /> Common: common wire nail; Box: galvanized box nail; Casing: casing nail; Roof: galvanized roofing nail; Cooler: cooler nail; WBoard: wallboard <br />nail; Screw: drywall screw; Gauge: nail measured by gauge; Galv: galvanized gauge nail; GWB: Gypsum wallboard blued nail <br />Size - From Tables 4.3A-D and Table A1; shown in Wall Input fastener dropdown <br /> Common nails: 6d = 0.113 x 2”, 8d = 0.131 x 2.5”, 10d = 0.148 x 3”, 12d = 0.148 x 3.5” <br /> Box or casing nails: 6d = 0.099 x 2”, 8d = 0.113 x 2.5”, 10d = 0.128 x 3”, 12d = 0.126 x 3.5” <br /> Gauge, roofing and GWB nails: 13 ga = 0.92” x 1-1/8”; 11 ga = 0.120” x 1-1/8” (GWB nail for gypsum lath & plaster), 1-1/4” (gyp. L&P), 1-1/2” <br />(wire lath & plaster, 1/2” fiberboard ,1/2” GWB), 1-3/4” (GSB, 5/8” GWB, 25/32” fiberboard, 2-ply GWB base), 2-3/8” (2-ply GWB face) <br /> Cooler or wallboard nail: 5d = .086” x 1-5/8”; 6d = .092” x 1-7/8”; 8d = .113” x 2-3/8”; 6/8d = 6d base ply, 8d face ply for 2-ply GWB. <br /> Drywall screws: No. 6, 1-1/4” long. <br />RS – Ring-shank nails (non-shearwalls only), with increased withdrawal capacity as per NDS 12.2.3.2. <br />Eg – Panel edge fastener spacing. For lumber sheathing, no. of nails per board at shear wall boundary. For 2-ply GWB, spacing of all nails in face <br />ply. <br />Fd – Field spacing interior to panels. For lumber sheathing, no. of nails per board at interior studs. For 2-ply GWB, spacing of all nails in face ply. <br />Bk – Sheathing is nailed to blocking at all panel edges; Y(es) or N(o) <br />Apply Notes – Notes below table legend which apply to sheathing side <br />FRAMING MATERIALS and STANDARD WALL by WALL GROUP <br />Wall Species Grade b d Spcg SG E Fcp Standard Wall <br />Grp in in in psi^6 <br />1 D.Fir-L Stud 1.50 3.50 16 0.50 1.40 625 <br />Legend: <br />Wall Grp – Wall Design Group <br />b – Stud breadth (thickness) <br />d – Stud depth (width) <br />Spcg – Maximum on-centre spacing of studs for design, actual spacing may be less. <br />SG – Specific gravity <br />E – Modulus of elasticity <br />Standard Wall - Standard wall designed as group. <br />Fcp - Compressive strength perpendicular to grain <br />Notes: <br />Check manufacture requirements for stud size, grade and specific gravity (G) for all shearwall hold-downs. <br />The following factors are applied to Fcp for compressive design and deformation under wall segment end studs : <br /> Bearing area factor Cb from NDS 3.10.4, under window openings. <br />3 <br />2726 W Strawberry Ln & <br />Unit# 23/17/2025