Laserfiche WebLink
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)424 @ 1' 6 3/4"1482 (1.50")Passed (29%)--1.0 D + 1.0 Lr (All Spans) <br />Shear (lbs)303 @ 2' 2 3/8"1631 Passed (19%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Moment (Ft-lbs)985 @ 7' 8 9/16"1700 Passed (58%)1.25 1.0 D + 1.0 Lr (Alt Spans) <br />Live Load Defl. (in)0.187 @ 7' 7 13/16"0.640 Passed (L/823)--1.0 D + 1.0 Lr (Alt Spans) <br />Total Load Defl. (in)0.379 @ 7' 7 15/16"0.854 Passed (L/405)--1.0 D + 1.0 Lr (Alt Spans) <br />Member Length : 14' 8 5/16" <br />System : Roof <br />Member Type : Joist <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 4/12 <br />•Deflection criteria: LL (L/240) and TL (L/180). <br />•Overhang deflection criteria: LL (2L/240) and TL (2L/180). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•A 15% increase in the moment capacity has been added to account for repetitive member usage. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Factored Accessories <br />1 - Stud wall - DF 1.50"1.50"1.50"217 206 424 Blocking <br />2 - Beveled Plate - DF 1.50"1.50"1.50"169 162 331 Blocking <br />•Maximum allowable bracing intervals based on applied load. <br />•Dimensions for lateral bracing intervals are measured along the length of the member for sloped conditions. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)10' 2" o/c <br />Bottom Edge (Lu)14' 6" o/c <br />Dead Roof Live <br />Vertical Load Location (Side)Spacing (0.90)(1.25)Comments <br />1 - Uniform (PSF)0 to 13' 9"16"20.0 20.0 ROOF <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by LY PHAN <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />Level, RR1 <br />1 piece(s) 2 x 8 DF No.2 @ 16" OC <br />ForteWEB Software Operator Job Notes 12/8/2024 5:23:57 PM UTC <br />Hai Pham <br />Gemini Design <br />(714) 707-8839 <br />hainp@uci.edu <br />ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 <br />File Name: 2726 STRAWBERRY <br />NEW DETACHED ADU IN SANTA ANA <br />Page 2 / 12 <br />2726 W Strawberry Ln & <br />Unit# 23/17/2025