Project : <br />Project Number: <br />By : <br />Date : <br />Minda Herman <br />PE <br />08-08-2024 <br />Check for Increase in overall seismic loads <br />Module Area =ft2 <br />Number of Modules = <br />Total Array Area =ft2 <br />Array Load = psf <br />Number of Existing Modules = <br />Existing Array Area =ft2 <br />Total Array Wt. = lb <br />Total Roof Area =ft2 <br />DL of Roof = psf <br />Total Wt. of Roof = lb <br />Increase in Seismic Wt. = < 10% <br />Conservatively the Wt. of the Walls tributary to the roof is not included. Seismic weight increase is less than <br />10% and no seismic retrofit or evaluation of existing lateral system is required per Section 503.4 of 2022 <br />CEBC. <br />21.1 <br />10 <br />211.21 <br />2379 <br />3.00 <br />633.63 <br />0 <br />0.00 <br />21.32 <br />50713 <br />1.2% <br />Page 15 <br />2704 W Camden Pl <br />9/26/2024