My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2701 N Grand - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Grand Ave
>
2701 N Grand Ave
>
2701 N Grand - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:18:55 PM
Creation date
6/6/2025 1:18:27 PM
Metadata
Fields
Template:
Plan
Permit Number
101121007
Full Address
2701 N Grand Ave
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />Broyles And Associates <br />508 Baylor Court, Suite C <br />Chesapeake, Virgnia 23320 <br />PH: 757-436-2070 <br />Project <br />Starbucks <br />Job Ref. <br /> <br />Section <br />115 MPH Sign Foundation Design <br />Sheet no./rev. <br /> 14 <br />Calc. by <br />RSW <br />Date <br />2021/30/2024 <br />4 <br />Chk'd by <br /> <br />Date <br /> <br />App'd by <br /> <br />Date <br /> <br /> <br />Concrete breakout strength in shear parallel to edge - Case 1. Half of shear resisted by front bolts ( parallel to edge - <br />Case 1. Half of shear resisted by front bolts) <br /> <br />Applied shear Vapp = 0.35 kips Edge distance x for shear ca1,p = 6 in <br />Edge distance y for shear ca2,p = 6 in Load bearing length of anchor le = 6 in <br />Basic conc breakout strength Vb,p = 7.24 kips Proj area of single anchor AVco,p = 162 in2 <br />Proj area of group of anchors AVc,p = 180 in2 Mod factor for edge effect ed,V,p = 1.000 <br />Eccentricity of loading e’V,p = 0 in Mod factor of eccentric load ec,V,p = 1.000 <br />Mod factor for cracking c,V = 1.200 Mod factor for edge distance h,V,p = 1.000 <br />Nom breakout strength shear Vcbg,p = 19.32 kips Concbreak out strength shear Vcbg,p = 14.49 kips <br />PASS - Shear breakout strength parallel to edge exceeds shear in bolts <br />Pryout strength of anchor in shear (17.5.3) <br />Coefficient of pryout strength kcp = 2.0 Nom pryout strength of anchor Vcpg = 21.55 kips <br />Pryout strength of anchor Vcpg = 15.09 kips <br />PASS - Pryout strength of anchor exceeds shear in bolts <br />Interaction of tensile and shear forces <br />Crit design strength tension Nn = 6.06 kips Crit applied tensile force Nua = 4.20 kips <br />Crit design strength shear Vn = 8.70 kips Crit applied shear force Vua = 0.70 kips <br />Nua / Nn = 0.693 Vua / Vn = 0.081 <br />As Vua / Vn <= 0.2,Full strength in tension is permitted <br />Pass - Applied tension is less than tension capacity <br /> <br /> <br />2701 N Grand Ave- <br />Sign12/5/2024
The URL can be used to link to this page
Your browser does not support the video tag.