LATERAL ANALYTICAL SECTION <br />(Per ASCE 7-16, IBC 2021,CBC 2022 & LABC 2023 Code)Job Number : 24058 <br />1 Plan : <br />GENERAL INPUT : (1 STORY) <br />Base Height Above Ground (ft)0.50 Plate Height (ft)8.00 <br />South Roof Height (N-S Direction-ft)11.50 West Roof Height (E-W Direction-ft)11.50 <br />South Roof Type (N-S Direction) Slope West Roof Type (E-W Direction) Slope <br />Roof Depth (N-S-ft)23.25 Roof Depth (E-W-ft)39 <br />Diaphragm Depth (N-S Direction-ft)21.5 Diaphragm Depth (E-W Direction-ft)37 <br />Diaphragm Span (N-S Direction-ft)37 Diaphragm Span(E-W Direction-ft)21.5 <br />Number of Ext. Wall (N-S)2 Number of Ext. Wall (E-W)2 <br />Number of Int. Wall (N-S)1 Number of Int. Wall (E-W)2 <br />SEISMIC ANALYSIS :(Using Equivalent Force Procedure per ASCE 7-16) <br />Determine Section Weight : <br />For N-S Direction : <br />Area(ft^2) Unit <br />Roof 906.75 16 <br />Ext.Wall(ft.)296 15 <br />Int. Wall(ft)148 10 <br />Sum:20,428 Ev(ASD) <br />Base Shear :(V=Cs*W) :2,298.5 4269 lbs <br />2.53 58.8225 <br />For E-W Direction : <br />Area(ft^2) Unit <br />Roof 906.75 16 <br />Ext.Wall(ft.)172 15 <br />Int. Wall(ft)172 10 <br />Sum:18,808 Ev(ASD) <br />Base Shear :(V=Cs*W) :2,116.2 3930 lbs <br />2.33 90.9 <br />WIND ANALYSIS :(MWFRS Directional Procedure Chapter 27 Part1 per ASCE 7-16 for Building of any Height) <br />The Velocity Pressures : <br />qz = 0.00256 Kz Kzt Kd V2 (ASCE 7-16 Equation27.3-1) <br />Kzt = 1.0 (Flat Terrian) <br />Kd = 0.85 (ASCE 7-16 Table 26.6-1) <br />Kz = 2.01*(max(z,15)/zg)(2/a)( ASCE 7-16 Tables 27.3-1) <br />h(ft)kz qz(psf) <br />Roof 10.33 0.849 22.35 <br />Wall 8.00 0.849 22.35 <br />p=qz*G*Cp-qi*(+/-GCpi) for windward wall (psf), where : qi=qh(Eq. 27.3-1, Sect.27.3.2) <br />p=qh*G*Cp-qi*(+/-GCpi) for leeward wall, side wall & roof (psf), where : qi=qh( Eq. 27.3-1, Sect.27.3.2) <br />The Internal Pressures: <br />Gcpi(+/-) 0.18 <br />qh 22.35 psf <br />+qhGCpi 4.02 psf <br />-qhGCpi -4.02 psf <br />(see next page for details) <br />SECTION NUMBER : <br />Weight(Ib) <br />14508 <br />4440 <br />1480 <br />Unit <br /> FN-S(psf) <br />Unit <br /> FN-S(plf) <br />Weight(Ib) <br />14508 <br />2580 <br />1720 <br />Unit <br /> FE-W(psf) <br />Unit <br /> FE-W(plf) <br />2201 W Seventh St <br />12/9/2024