STRUCTURAL STEEL <br />REINFORCED CONCRETE <br />WOOD <br />CONCRETE MASONRY <br />STRUCTURAL WOODGENERAL REQUIREMENTS <br />1.IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO VERIFY ALL GRADES, <br />DIMENSIONS, ELEVATIONS AND CONDITIONS AT THE JOB SITE PRIOR TO BIDDING <br />AND COMMENCING CONSTRUCTION. CROSS CHECK ALL DETAILS AND <br />DIMENSIONS SHOWN ON THE STRUCTURAL DRAWINGS WITH RELATED <br />REQUIREMENTS ON THE ARCHITECTURAL, ELECTRICAL, MECHANICAL, AND CIVIL <br />DRAWINGS AND NOTIFY THE ENGINEER AND THE ARCHITECT OF ANY <br />DISCREPANCIES PRIOR TO STARTING WORK. <br />2.EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE NOTED OR SHOWN IN <br />THE PLANS OR SPECIFICATIONS, ALL PHASES OF WORKMANSHIP AND MATERIALS <br />SHALL CONFORM TO THE REQUIREMENTS OF THE BUILDING CODE, LATEST <br />ADDITION, AS WELL AS ALL APPLICABLE STATE AND LOCAL ORDINANCES AS <br />ADOPTED BY THE CONTROLLING JURISDICTION. <br />3.THE CONTRACT DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO NOT <br />INDICATE THE METHOD OF CONSTRUCTION. THE STRUCTURE SHOWN ON THESE <br />DRAWINGS IS STRUCTURALLY SOUND ONLY IN THE COMPLETED FORM. GENERAL <br />CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE <br />STRUCTURE, WORKMEN, AND OTHER PERSONS DURING CONSTRUCTION. SUCH <br />MEASURES INCLUDE, BUT ARE NOT LIMITED TO; BRACING, SHORING FOR <br />CONSTRUCTION EQUIPMENT,AND SHORING FOR THE STRUCTURE. <br />4.TIN NO CASE SHALL DIMENSIONS BE SCALED FROM DRAWINGS AND/OR DETAILS. <br />ANY DISCREPANCIES FOUND WITHIN THE CONTRACT DOCUMENTS SHALL BE <br />BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER FOR <br />CLARIFICATION PRIOR TO PROCEEDING. ANY WORK INSTALLED PRIOR TO <br />AND/OR IN CONFLICT WITH SUCH CLARIFICATION SHALL BE CORRECTED BY THE <br />CONTRACTOR AT HIS EXPENSE AND AT NO ADDITIONAL COST TO THE OWNER. <br />5.THE PRECISE DIMENSIONS AND LOCATIONS OF ALL DOOR AND WINDOW <br />OPENINGS, INTERIOR AND EXTERIOR WALLS SHALL BE DETERMINED FROM THE <br />ARCHITECTURAL DRAWINGS. OTHER FLOOR, WALL AND ROOF OPENINGS AS <br />REQUIRED FOR MECHANICAL, ELECTRICAL AND/OR SIMILAR REQUIREMENTS <br />SHALL BE VERIFIED FROM SHOP DRAWINGS, EQUIPMENT DATA, ETC. AS <br />REQUIRED. <br />6.FLOOR AND WALL OPENINGS, SLEEVES, VARIATIONS IN STRUCTURAL SLAB <br />ELEVATIONS, DEPRESSED AREAS, AND ALL OTHER ARCHITECTURAL, <br />MECHANICAL, ELECTRICAL, AND/OR CIVIL REQUIREMENTS MUST BE <br />COORDINATED BEFORE THE CONTRACTOR PROCEEDS WITH CONSTRUCTION. <br />7.THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION AND <br />COORDINATION WITH ARCHITECTURAL, CIVIL, MECHANICAL, ELECTRICAL, <br />PLUMBING, FIRE SPRINKLER DRAWINGS,AND ALL OTHER RELATED DRAWINGS. <br />THE CONTRACTOR IS RESPONSIBLE FOR THE AND ALL OTHER RELATED <br />DRAWINGS. <br />8.IN ALL CASES WHERE A CONFLICT MAY OCCUR SUCH AS BETWEEN ITEMS <br />INCLUDED IN THE SPECIFICATIONS AND NOTES ON THE DRAWINGS, OR BETWEEN <br />GENERAL NOTES AND SPECIFIC DETAILS, THE ENGINEER SHALL BE NOTIFIED AND <br />HE WILL INTERPRET THE INTENT OF THE CONTRACT DOCUMENTS. <br />9.ALL MATERIALS SHALL BE FURNISHED AS SHOWN HEREIN UNLESS ALTERNATES <br />ARE APPROVED IN WRITING BY THE ARCHITECT, OWNER AND STRUCTURAL <br />ENGINEER OF RECORD. <br />10.ANY REFERENCE TO THE WORDS APPROVED OR APPROVAL IN THESE <br />DOCUMENTS SHALL BE DEFINED TO MEAN GENERAL ACCEPTANCE OR REVIEW <br />AND SHALL NOT RELIEVE THE CONTRACTOR AND/OR HIS SUBCONTRACTORS OF <br />ANY LIABILITY IN FURNISHING THE REQUIRED MATERIALS OR LABOR <br />SPECIFICATION. <br />11.WHERE A DETAIL, SECTION OR NOTE IS SHOWN FOR ONE CONDITION, IT SHALL <br />APPLY FOR ALL LIKE OR SIMILAR CONDITIONS UNLESS NOTED OTHERWISE. <br />DETAILS MARKED "TYPICAL" SHALL APPLY IN ALL CASES UNLESS SPECIFICALLY <br />INDICATED OTHERWISE. WHERE NO SPECIFIC DETAIL IS SHOWN, THE FRAMING <br />OR CONSTRUCTION SHALL BE IDENTICAL OR SIMILAR TO LIKE CASES OF <br />CONSTRUCTION. <br />12.CONNECTIONS OF ALL ITEMS SUPPORTED BY THE STRUCTURE ARE THE <br />RESPONSIBILITY OF THE DISCIPLINES WHO MAKE THESE ATTACHMENTS. REVIEW <br />AND COORDINATE ALL THE REQUIREMENTS IN THE ARCHITECTS PROJECT <br />SPECIFICATION AS APPLICABLE. <br />13.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING <br />UTILITIES, WHETHER INDICATED ON THE CONTRACT DRAWING OR NOT, AND TO <br />PROTECT THEM FROM DAMAGE. REPAIR AND REPLACEMENT OF SAID WORK <br />SHALL BE AT THE EXPENSE OF THE CONTRACTOR. <br />14.VIBRATIONAL EFFECTS OF MECHANICAL AND/OR ANY OTHER EQUIPMENT HAVE <br />NOT BEEN CONSIDERED BY THE STRUCTURAL ENGINEER. <br />15.UNLESS NOTED OTHERWISE, ELEVATIONS SHOWN ON THE STRUCTURAL <br />DRAWINGS ARE TO THE TOP OF BEAMS AND FOUNDATIONS. BEAMS DENOTED AS <br />"DROP" HAVE THE TOP OF BEAM AT THE HEIGHT OF THE TOP PLATE. BEAMS <br />DENOTED AS "FLUSH" HAVE THE BOTTOM OF BEAM AT THE HEIGHT OF THE TOP <br />PLATE, U.N.O. <br />5.LUMBER GRADES ( U.N.O. ) <br />6X & 8X POSTS/BEAMS/HEADERS: #1 DFL <br />4X POSTS/BEAMS/HEADERS: #2 DFL <br />2X JOISTS/RAFTERS: #2 DFL <br />STUDS: D.F.L. STUD GRADE (UP TO 9'-0"), D.F.L. #2 (HIGHER THAN 9'-0") <br />TOP PLATES & MUD SILLS: D.F.L. CONSTRUCTION GRADE,#2, OR BETTER. <br />6.TYPICAL FLOOR SHEATHING <br />23/32" APA RATED STURD-I-FLOOR T&G EXP I (OR OSB) WITH MIN. <br />SPAN RATING OF 24" O.C. REFER TO NER 108 FOR INSTALLATION AND CONDITIONS <br />OF USE <br />B.N.:10D COMMON NAILS AT 6" O.C. <br />E.N.:10D COMMON NAILS AT 6" O.C. <br />F.N.:10D COMMON NAILS AT 12" O.C. <br />USE RING OR SCREW SHANK NAILS AND GLUE SHEATHING TO FRAMING USING <br />ADHESIVES MEETING APA SPECIFICATION AFG-01 OR ASTM D3498. APPLY GLUE IN <br />ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. <br />AS AN ALTERNATE TO 10D COMMON NAILS, THE FOLLOWING FASTNERS CAN BE <br />USED: GRABBER PLYWOOD SCREWS (ICC-ER-5280), OR SIMPSON STRONG-TIE <br />QUICK DRIVE SCREWS (ICC-ER-1472), MIN 2" LONG @ 6" O.C. B.S., @ 6" O.C. E.S. <br />AND 12" O.C. F.S. <br />7.TYPICAL ROOF SHEATHING DOC PS1 OR DOC PS2. <br />15/32" APA RATED SHEATHING EXP 1 (OR OSB) WITH A MIN. PANEL INDEX OF 32/16. <br />REFER TO NER 108 FOR INSTALLATION AND CONDITIONS OF USE. <br />B.N.:8D COMMON NAIL AT 6" O.C. <br />E.N.:8D COMMON NAIL AT 6" O.C. <br />F.N.:8D COMMON NAIL AT 12" O.C. <br />NOTE*: ALL STRUCTURAL RATED PANELS MUST BE STAMPED BY ONE OF THE <br />FOLLOWING APPROVED AGENCIES, APA, PFS/TECO OR PITTSBURG. <br />SHEAR WALL NOTES: <br />1.FRAMING AT ADJOINING PANEL EDGES SHALL BE 3 INCHES NOMINAL OR WIDER, AND NAILS <br />SHALL BE STAGGERED WHERE NAILS ARE SPACED 2 INCHES ON CENTER. <br />2.WHERE SHEAR DESIGN VALUES EXCEED 350 PLF., ALL FRAMING MEMBERS RECEIVING <br />EDGE NAILING FROM ABUTTING PANELS SHALL NOT BE LESS THAN A SINGLE 3-INCH <br />NOMINAL MEMBER, OR TWO 2-INCH NOMINAL MEMBERS FASTENED TOGETHER IN <br />ACCORDANCE WITH SECTION 2306.1 TO TRANSFER THE DESIGN SHEAR VALUE BETWEEN <br />FRAMING MEMBERS. WOOD STRUCTURAL PANEL JOINT AND SILL PLATE NAILING SHALL BE <br />STAGGERED IN ALL CASES. SEE SECTION 2305.3.11 FOR SILL PLATE SIZE AND ANCHORAGE <br />REQUIREMENTS. NAILS SHALL BE PLACED NOT LESS THAN 1/2" EDGE DISTANCE FROM THE <br />PANEL EDGES AND 3/8" FROM THE EDGE OF THE CONNECTING <br />MEMBERS. <br />3.ANCHOR BOLTS FOR SHEAR WALLS SHALL INCLUDE STEEL PLATE WASHERS, A MINIMUM <br />OF 0.229 INCHES BY 3 INCHES BY 3 INCHES IN SIZE, BETWEEN THE SILL PLATE AND NUT. <br />ANCHOR BOLTS: <br />1.MINIMUM 5/8"Ø STEEL BOLTS EMBEDDED 7" @ 48" O.C. INTO THE FOUNDATION WITH <br />MINIMUM 3" S.Q x 0.25" PLATE WASHER FOR THE ANCHOR BOLTS. MINIMUM EDGE DISTANCE <br />1-7/8" AND WITHIN 12" OF EACH END OF EACH PLATE. <br />2.ALL SHEAR HARDWARE AND ANCHOR BOLTS W/ NON-STANDARD SPACING ARE TO BE FIXED <br />IN PLACE FOR THE FOUNDATION INSPECTION. <br />3.FASTENERS FOR PRESERVATIVE-TREATED SHALL BE NOT DIPPED ZINC-COATED <br />GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. <br />4.A PROPERLY SIZED NUT AND WASHER SHALL BE TIGHTENED ON EACH ANCHOR BOLT TO <br />THE PLATE. <br />5.HOLDOWN CONNECTORS BOLTS HOLES SHALL NOT BE MORE THAN 1/16" OVERSIZED AT <br />THE CONNECTOR OF THE HOLD DOWN TO THE POST. <br />6.HOLD DOWN CONNECTORS SHALL BE RE-TIGHTENED JUST PRIOR TO COVERING THE WALL <br />FRAMING. <br />7.ALL FOUNDATIONS SHALL BEAR UPON LIKE MATERIAL. <br />8.FINAL SOILS / AS-GRADED REPORT WILL BE REQUIRED AT FOUNDATION / SLAB INSPECTION. <br />NAILING SCHEDULE: (TABLE R602.3(1) W/ FOOT NOTES 2022 CRC) <br />ITEM DESCRIPTION OF BUILDING <br />ELEMENTS <br />NUMBER AND TYPE OF <br />FASTENERa, b, c <br />SPACING AND <br />LOCATION <br />1 Blocking between ceiling joists or <br />rafters to top plate <br />4-8d box (2 1/2″ × 0.113″) or 3-8d <br />common (2 1/2″ × 0.131″); or 3-10d box <br />(3″ × 0.128″); or 3-3″ × 0.131″ nails <br />Toe nail <br />2 Ceiling joists to top plate <br />4-8d box (2 1/2″ × 0.113″); or 3-8d <br />common 2 1/2″ × 0.131″); or 3-10d box <br />(3″ × 0.128″); or 3-3″ × 0.131″ nails <br />Per joist, toe nail <br />3 <br />Ceiling joist not attached to parallel <br />rafter, laps over partitions [see <br />Sections R802.3.1, R802.3.2 and <br />Table R802.5.1(9)] <br />4-10d box (3″ × 0.128″); or 3-16d <br />common (3 1/2″ × 0.162″); <br />or 4-3″ × 0.131″ nails <br />Face nail <br />4 <br />Ceiling joist attached to parallel rafter <br />(heel joint) [see Sections R802.3.1 <br />and R802.3.2 and Table R802.5.1(9)] <br />Table R802.5.1(9)Face nail <br />5 Collar tie to rafter, face nail or 11/4″ × <br />20 ga. ridge strap to rafter <br />4-10d box (3″ × 0.128″); or 3-10d <br />common (3″ × 0.148″); <br />or 4-3″ × 0.131″ nails <br />Face nail each rafter <br />6 Rafter or roof truss to plate <br />3-16d box nails (3 1/2″ × 0.135″); <br />or 3-10d common nails (3″ × 0.148″); <br />or 4-10d box (3″ × 0.128″); <br />or 4-3″ × 0.131″ nails <br />2 toe nails on one <br />side and 1 toe nail on <br />opposite side of each <br />rafter or truss <br />7 <br />Roof rafters to ridge, valley <br />or hip rafters or roof rafter to <br />minimum 2″ ridge beam <br />4-16d (3 1/2″ × 0.135″); or 3-10d <br />common (3 1/2″ × 0.148″); or 4-10d box <br />(3″ × 0.128″); or 4-3″ × 0.131″ nails <br />Toe nail <br />3-16d box 3 1/2″ × 0.135″); or 2-16d <br />common (3 1/2″ × 0.162″); or 3-10d box <br />(3″ × 0.128″); or 3-3″ × 0.131″ nails <br />End nail <br />WALL <br />8 Stud to stud (not at braced wall <br />panels) <br />16d common (3 1/2″ × 0.162″)24″ o.c. face nail <br />10d box (3″ × 0.128″); <br />or 3″ × 0.131″ nails 16″ o.c. face nail <br />9 <br />Stud to stud and abutting studs at <br />intersecting wall corners (at braced <br />wall panels) <br />4-10d box (3″ × 0.128″); or 3-16d <br />common (3 1/2″ × 0.162″); <br />or 4-3″ × 0.131″ nails <br />12″ o.c. face nail <br />16d common (3 1/2″ × 0.162″)16″ o.c. face nail <br />10 Built-up header (2″ to 2″ header with <br />1/2″ spacer) <br />16d common (3 1/2″ × 0.162″)16″ o.c. each edge <br />face nail <br />16d box (3 1/2″ × 0.135″)12″ o.c. each edge <br />face nail <br />11 Continuous header to stud <br />5-8d box (2 1/2″ × 0.113″); <br />or 4-8d common (2 1/2″ × 0.131″); <br />or 4-10d box (3″ × 0.128″) <br />Toe nail <br />12 Top plate to top plate <br />16d common (3 1/2″ × 0.162″)16″ o.c. face nail <br />10d box (3″ × 0.128″); <br />or 3″ × 0.131″ nails 12″ o.c. face nail <br />13 <br />Double top plate splice for SDCs <br />A-D2 with seismic braced wall line <br />spacing < 25' <br />8-16d common (3 1/2″ × 0.162″); or <br />12-16d box (3 1/2″ × 0.135″); or 12-10d <br />box (3″ × 0.128″); or 12-3″ × 0.131″ nails <br />Face nail on each <br />side of end joint <br />(minimum 24″ lap <br />splice length each <br />side of end joint)Double top plate splice SDCs D0, D1, <br />or D2; and braced wall line spacing ≥ <br />25' <br />12-16d (3 1/2″ × 0.135″) <br />14 <br />Bottom plate to joist, rim joist, band <br />joist or blocking (not at braced wall <br />panels) <br />16d common (3 1/2″ × 0.162″)16″ o.c. face nail <br />16d box (3 1/2″ × 0.135″); <br />or 3″ × 0.131″ nails 12″ o.c. face nail <br />15 <br />Bottom plate to joist, rim joist, band <br />joist or blocking (at braced wall <br />panel) <br />3-16d box (3 1/2″ × 0.135″); <br />or 2-16d common (3 1/2″ × 0.162″); <br />or 4-3″ × 0.131″ nails <br />3 each 16″ o.c. face <br />nail 2 each 16″ o.c. <br />face nail 4 each 16″ <br />o.c. face nail <br />16 Top or bottom plate to stud <br />4-8d box (2 1/2″ × 0.113″); or 3-16d box <br />(3 1/2″ × 0.135″); or 4-8d common <br />(2 1/2″ × 0.131″); or 4-10d box (3″ × <br />0.128″); or 4-3″ × 0.131″ nails <br />Toe nail <br />3-16d box (3 1/2″ × 0.135″); or 2-16d <br />common (3 1/2″ × 0.162″); or 3-10d box <br />(3″ × 0.128″); or 3-3″ × 0.131″ nails <br />End nail <br />17 Top plates, laps at corners and <br />intersections <br />3-10d box (3″ × 0.128″); or 2-16d <br />common (3 1/2″ × 0.162″); <br />or 3-3″ × 0.131″ nails <br />Face nail <br />18 1″ brace to each stud and plate <br />3-8d box (2 1/2″ × 0.113″); or 2-8d <br />common (2 1/2″ × 0.131″); or 2-10d box <br />(3″ × 0.128″); or 2 staples 1 3/4″ <br />Face nail <br />19 1″ × 6″ sheathing to each bearing <br />3-8d box (2 1/2″ × 0.113″); or 2-8d <br />common (2 1/2″ × 0.131″); or 2-10d box <br />(3″ × 0.128″); or 2 staples, 1″ crown, <br />16 ga., 1 3/4″ long <br />Face nail <br />20 1″ × 8″ and wider sheathing to each <br />bearing <br />3-8d box (2 1/2″ × 0.113″); or 3-8d <br />common (2 1/2″ × 0.131″); or 3-10d box <br />(3″ × 0.128″); or 3 staples, <br />1″ crown, 16 ga., 1 3/4″ long Face nailWider than 1″ × 8″ 4-8d box (2 1/2″ × <br />0.113″); 3-8d common (2 1/2″ × 0.131″); <br />or 3-10d box (3″ × 0.128″); or 4 staples, <br />1″ crown, 16 ga., 1 3/4″ long <br />FLOOR <br />21 Joist to sill, top plate or girder <br />4-8d box (2 1/2″ × 0.113″); or 3-8d <br />common (2 1/2″ × 0.131″); or 3-10d box <br />(3″ × 0.128″); or 3-3″ × 0.131″ nails <br />Toe nail <br />22 Rim joist, band joist or blocking to sill <br />or top plate (roof applications also) <br />8d box (2 1/2″ × 0.113″)4″ o.c. toe nail <br />8d common (2 1/2″ × 0.131″); <br />or 10d box (3″ × 0.128″); <br />or 3″ × 0.131″ nails <br />6″ o.c. toe nail <br />23 1″ × 6″ subfloor or less to each joist <br />3-8d box (2 1/2″ × 0.113″); or 2-8d <br />common (2 1/2″ × 0.131″); or 3-10d box <br />(3″ × 0.128″); or 2 staples, 1″ crown, <br />16 ga., 1 3/4″ long <br />Face nail <br />24 2″ subfloor to joist or girder 3-16d box (3 1/2″ × 0.135″); or 2-16d <br />common (3 1/2″ × 0.162″)Blind and face nail <br />25 2″ planks <br />(plank & beam—floor & roof) <br />3-16d box (3 1/2″ × 0.135″); or 2-16d <br />common (3 1/2″ × 0.162″) <br />At each bearing, face <br />nail <br />26 Band or rim joist to joist <br />3-16d common (3 1/2″ × 0.162″) 4-10 <br />box (3″ × 0.128″), or 4-3″ × 0.131″ nails; <br />or 4-3″ × 14 ga. staples, 7/16″ crown <br />End nail <br />27 Built-up girders and beams, 2-inch <br />lumber layers <br />20d common (4″ × 0.192″) <br />Nail each layer as <br />follows: 32″ o.c. at top <br />and bottom and <br />staggered. <br />10d box (3″ × 0.128″); <br />or 3″ × 0.131″ nails <br />24″ o.c. face nail at <br />top and bottom <br />staggered on <br />opposite sides <br />And: 2-20d common (4″ × 0.192″); <br />or 3-10d box (3″ × 0.128″); <br />or 3-3″ × 0.131″ nails <br />Face nail at ends and <br />at each splice <br />28 Ledger strip supporting joists or <br />rafters <br />4-16d box (3 1/2″ × 0.135″); or 3-16d <br />common (3 1/2″ × 0.162″); or 4-10d box <br />(3″ × 0.128″); or 4-3″ × 0.131″ nails <br />At each joist or rafter, <br />face nail <br />29 Bridging to joist 2-10d (3″ × 0.128″)Each end, toe nail <br />ITEM DESCRIPTION OF BUILDING <br />ELEMENTS <br />NUMBER AND TYPE OF FASTENER a, <br />b, c <br />SPACING OF <br />FASTENERS <br />Edges <br />(inches)h <br />Intermediat <br />e supports <br />c, e (inches) <br />Wood structural panels, subfloor, roof and interior wall sheathing to framing and particleboard wall sheathing <br />to framing [see Table R602.3(3) for wood structural panel exterior wall sheathing to wall framing] <br />30 3/8″ – 1/2″ <br />6d common (2″ × 0.113″) nail <br />(subfloor, wall) 8d common <br />(21/2″ × 0.131″) nail (roof) <br />6 12f <br />31 19/32″ – 1″8d common nail (21/2″ × 0.131″)6 12f <br />32 11/8″ – 11/4″10d common (3″ × 0.148″) nail; or 8d <br />(21/2″ × 0.131″) deformed nail 6 12 <br />Other wall sheathing <br />33 1/2″ structural cellulosic fiberboard <br />sheathing <br />1 1/2″ galvanized roofing nail, 7/16″ head <br />diameter, or 1″ crown staple 16 ga., 1 <br />1/4″ long <br />3 6 <br />34 25/32″ structural cellulosic fiberboard <br />sheathing <br />1 3/4″ galvanized roofing nail, 7/16″ head <br />diameter, or 1″ crown staple 16 ga., 1 <br />1/4″ long <br />3 6 <br />35 1/2″ gypsum sheathingd <br />1 1/2″ galvanized roofing nail; staple <br />galvanized, 1 1/2″ long; 1 1/4″ screws, <br />Type W or S <br />7 7 <br />36 5/8″ gypsum sheathingd <br />1 3/4″ galvanized roofing nail; staple <br />galvanized, 1 5/8″ long; 1 5/8″ screws, <br />Type W or S <br />7 7 <br />Wood structural panels, combination subfloor underlayment to framing <br />37 3/4″ and less 6d deformed (2″ × 0.120″) nail; or 8d <br />common (2 1/2″ × 0.131″) nail 6 12 <br />38 7/8″ – 1″8d common (2 1/2″ × 0.131″) nail; or 8d <br />deformed (2 1/2″ × 0.120″) nail 6 12 <br />39 1 1/8″ – 1 1/4″10d common (3″ × 0.148″) nail; or 8d <br />deformed (2 1/2″ × 0.120″) nail 6 12 <br />1.REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE WITH ACI 315 AND ACI 318, <br />AND CRSI'S MANUAL OF STANDARD PRACTICE. <br />2.REINFORCING STEEL SHALL CONFORM TO ASTM A615OR ASTM 716(WELDABLE <br />STEEL) AND SHALL BE GRADE 60 DEFORMED BARS, TYP., U.N.O. REINFORCING IN <br />SLAB ON GRADE MAYBE GRADE 40 STEEL FOR BARS #4 AND SMALLER U.N.O ON THE <br />PLANS. <br />3.WELDED WIRE FABRIC (WWF) SHALL CONFORM TO ASTM A185. LAPS IN WWF SHALL <br />BE SUCH THAT THE OVERLAP MEASURED BETWEEN OUTERMOST CROSS WIRE OF <br />EACH FABRICH SEET IS NOT LESS THAN THE SPACING OF CROSS WIRES PLUS 2 <br />INCHES. <br />4.ALL DIMENSIONS SHOWING THE LOCATION OF REINFORCING BARS/STEEL ARE TO <br />THE CENTER OF STEEL U.N.O. ON THE PLANS OR DETAILS: <br />CONDITION COVER <br />A. CAST AGAINST AND PERMANENTLY EXPOSED <br />TO EARTH 3" <br />B. EXPOSED TO EARTH OR WEATHER <br />(INCLUDING SLABS ON GRADE) <br />#6 AND LARGER 2" <br />#5 AND SMALLER 1 1/2" <br />C. NOT EXPOSED TO WEATHER OR <br /> IN CONTACT WITH SOIL: <br />1. STRUCTURAL SLABS, WALLS w/ <br /> #11 BARS AND SMALLER 3/4" <br /> #14 BARS AND LARGER 1 1/2" <br />2. BEAMS, COLUMNS 1 1/2" <br />5.LAP SPLICES OF BARS SHALL CONFORM TO THE TYPICAL THE LAP SCHEDULE ON THE <br />PLANS, U.N.O. NO TACK WELDING OF BARS ALLOWED <br />6.MECHANICAL SPLICE COUPLERS MAY BE USED AND SHALL HAVE CURRENT ICC <br />APPROVAL AND BE CAPABLE OF DEVELOPING 125% OF THE BAR'S YIELD STRENGTH. <br />7.ALL REINFORCING BARS SHALL BE BENT COLD. DO NOT FIELD BEND OR UNBEND ANY <br />BARS IN A MANNER THAT MAY DAMAGE REINFORCING. <br />8.REINFORCING SPACING SHOWN ON THE PLANS ARE THE MAXIMUM SPACING "ON <br />CENTER SPACING". DO NOT EXCEED THIS. ANY DISCREPANCIES DURING <br />CONSTRUCTION SHALL BE FORWARDED TO THE ENGINEER FOR REVIEW AND <br />APPROVAL. <br />9.TYPICAL REINFORCING FOR CONCRETE SLAB ON METAL DECK SHALL BE <br />6x6-W1.4xW1.4 WELDED WIRE FABRIC, U.N.O. PLACE WWF MID-DEPTH OF THE SLAB <br />OVER THE TOP OF THE FLUTE OF THE METAL DECK. <br />10.ALL DOWELS TO BE SET IN CONCRETE SHALL BE TIED IN PLACE PRIOR TO <br />PLACEMENT OF CONCRETE. NO WET SETTING, STABBING, RODDING OR OTHER <br />MOVEMENT OF EMBEDDED ITEMS SHALL BE PERFORMED DURING THE PLACEMENT <br />OF CONCRETE. <br />11.DOWELS BETWEEN FOOTING AND WALLS OR COLUMNS SHALL BE THE SAME GRADE, <br />SIZE AND SPACING AS THE MAIN REINFORCING, UNO. <br />12.CHAIRS OR SPACERS FOR REINFORCING SHALL BE NON-FERROUS OR PLASTIC <br />COATED WHEN RESTING ON EXPOSED SURFACES. <br />1.CONCRETE SHALL BE SUPPLIED AND PLACED IN ACCORDANCE WITH THE LATEST <br />EDITION OF ACI 318 AND ACI 301 EXCEPT AS MODIFIED BY THE CONSTRUCTION <br />DOCUMENTS. <br />2.PORLAND CEMENT SHALL CONFORM TO ASTM C-150, TYPE II, U.N.O. <br />3.AGGREGATE FOR STONE CONCRETE SHALL CONFORM TO ASTM C-33. FOR <br />LOWSHRINKAGE AGGREGATE, USE LIMESTONE OR GRANITE. AGGREGATE <br />FORLIGHTWEIGHTCONCRETE SHALL CONFORM TO ASTM C-330 <br />4.DO NOT USE ANY CONCRETE OR GROUT CONTAINING CHLORIDES. WATER USED IN <br />MIXING CONCRETE SHALL CONFORM WITH ASTM C1602. <br />5.CONCRETE MIX DESIGNS CONTAINING FLY ASH MAY BE USED WHERE CONCRETE IS <br />NOT VISUALLY EXPOSED. FLY ASH SHALL CONFORM WITH ASTM C618 AND MAY <br />REPLACE UP TO 20% PORTLAND CEMENT BY VOLUME. <br />6.CONCRETE STRENGTH TEST REPORTS SHALL BE IN COMPLIANCE WITH ACI 318 AND <br />SHALL BE SUBMITTED TO E.O.R. FOR REVIEW. <br />7.ALL REINFORCING BARS, ANCHOR BOLTS AND ALL OTHER CONCRETE INSERTS <br />SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE. <br />8.THE CONCRETE COMPRESSIVE STRENGTH (28 DAYS), f'c: <br />a. ALL LOCATIONS, U.N.O: MIN 2500 PSI, (W/C = 0.45) SPECIAL INSPECTION IS <br />REQUIRED WHEN f'c > 2500 PSI. <br />b. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 ≥ 0.1% BY WEIGHT: <br />4000 PSI, SPECIAL INSPECTION IS NOT REQUIRED. <br />c. CONCRETE IN CONTACT WITH SOIL CONTAINING SULFATE So4 ≥ 0.2% BY WEIGHT: <br />4500 PSI, SPECIAL INSPECTION IS NOT REQUIRED. <br />9.TIME BETWEEN CONCRETE BATCHING AND PLACEMENT SHALL BE IN ACCORDANCE <br />WITH ASTM C94. <br />10.CONCRETE PLACEMENT/CURING/REDUCTION IN STRENGTH SHALL CONFORM TO ACI <br />305R AND 3065R REQUIREMENTS FOR HOT AND COLD WEATHER CONCRETING. <br />11.CONCRETE SHALL BE CURED PER ACI 308R, UNLESS ALTERNATE METHODS OF <br />CURING HAVE BEEN APPROVED BY THE ARCHITECT OR ENGINEER. FOR SLAB <br />CURING, CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING COMPATIBILITY OF <br />CURING COMPOUNDS WITH PROPOSED FINISHES PRIOR TO COMMENCING ANY <br />WORK. <br />12.MAX. SLUMP SHALL BE 5 INCHES EXCEPT WHERE ADMIXTURES/PLACITIZERS HAVE <br />BEEN ADDED IN THE MIX DESIGN TO IMPROVE FLOW ABILITY/WORKABILITY. THE <br />SLUMP LIMIT SHALL BE BASED ON ADMIXTURE MANUFACTURER'S <br />RECOMMENDATIONS. <br />1.ALL STRUCTURAL LUMBER SHALL BE DOUGLAS FIR LARCH CONFORMING TO WEST <br />COAST LUMBER INSPECTION BUREAU GRADING RULES #17. MOISTURE CONTENT NOT <br />TO EXCEED 19% AT TIME OF CONSTRUCTION. <br />2.WOOD-BASED STRUCTURAL USE PANELS SHALL MEET THE REQUIREMENTS OF DOC <br />PS 2-10. STRUCTURAL SHEATHING MAY BE EITHER OSB OR PLYWOOD. <br />3.STRUCTURAL COMPOSITE LUMBER (SCL) SHALL CONFORM TO THE MANUFACTURER'S <br />ICC REPORT IN COMPLIANCE WITH THE GOVERNING BUILDING CODE FOR THE <br />PROJECT LISTED. <br />4.ENGINEERED GLU-LAM BEAMS SHALL BE INSPECTED AND AN A.I.T.C. CERTIFICATE OF <br />COMPLIANCE SHALL BE PROVIDED TO THE INSPECTOR PRIOR TO INSTALLATION. ALL <br />GLU-LAM BEAMS SHALL BE FABRICATED WITH WATERPROOF GLUE WITH STANDARD <br />CAMBER U.N.O. <br />5.GLU-LAM BEAMS MAY NOT BE SUBSTITUTED FOR STRUCTURAL COMPOSITE LUMBER <br />(SCL) BEAMS UNLESS WRITTEN AUTHORIZATION IS PROVIDED BY THE ENGINEER OF <br />RECORD. <br />6.ALL WOOD FRAMING MEMBERS DIRECTLY AGAINST CONCRETE OR MASONRY <br />INSTALLED IN A DRY OR ENCLOSED ENVIRONMENT SHALL BE PRESSURE TREATED <br />DOUG-FIR TREATED WITH SODIUM BORATE (SBX/DOT). CORROSION RESISTANT <br />CONNECTORS ARE NOT REQUIRED WITH SODIUM BORATE TREATED LUMBER. IF <br />OTHER TREATMENTS ARE USED, GALVANIZED FASTENERS PER "FASTENER <br />REQUIREMENTS" NOTE 3 ARE REQUIRED. <br />7.LUMBER GRADE STAMPS ARE TO REMAIN IN PLACE AFTER INSTALLATION WHERE <br />POSSIBLE. <br />8.LUMBER GRADES ARE TO BE AS FOLLOWS: <br />STUDS UP TO 10'-0"..............................................................................................STUD GRADE <br />STUDS OVER 10'-0".............................................................................................................DF #2 <br />BLOCKING............................................................................................STANDARD OR BETTER <br />PLATES & SILL.....................................................................................STANDARD OR BETTER <br />TOP PLATES........................................................................................................................DF #2 <br />4X4 BEAMS/POSTS.............................................................................STANDARD OR BETTER <br />4X6 THROUGH 4X12BEAMS/POSTS.................................................................................DF #2 <br />4X14BEAMS/POSTS.............................................................................................................DF#1 <br />6X & LARGER BEAMS/POSTS............................................................................................DF #1 <br />2X RAFTER/JOIST...............................................................................................................DF #2 <br />9.UTILITY GRADE LUMBER IS UNACCEPTABLE FOR ANY PURPOSE. <br />10.THE FOLLOWING BEAMS/HEADERS/RIMS CAN BE FROM ANY MANUFACTURER WITH <br />CURRENT <br /> APPROVED ICC ES - EVALUATION REPORT WITH THE FOLLOWING MECHANICAL <br /> PROPERTIES: <br /> FOR "LVL" & "PSL" BEAMS: <br /> Fb = 2900 psi (MIN), Fv = 290 psi (MIN), E = 2.0 x 106 psi (MIN). <br /> FOR "LSL" BEAMS/HEADERS: <br /> Fb = 2325 psi (MIN), Fv = 400 psi (MIN), E = 1.55 x 106 psi (MIN). <br /> FOR MANUFACTURED RIM BOARD WITH MIN 1 1/4" THICK, CONTINUOUSLY SUPPORTED <br /> BY WALL , AND MATCHES JOIST DEPTH: <br /> Fc I (PERPENDICULAR)........ = 680 psi (MIN) <br /> Fc // (PARALLEL)..................... = 1400 psi (MIN) <br /> Ft = 1075 psi (MIN), E = 1.3 x 106 psi (MIN) <br /> GLU-LAM BEAM SHALL BE 24F-V4, DF/DF <br /> Fb = 2400 psi @ BOTTOM, Fb = 1850 psi @ TOP <br /> Fv = 265 psi (MIN), E = 1.8 x 106 psi (MIN). <br />11.ROOF SHEATHING SHALL BE 15/32" APA RATED SHEATHING EXP 1 WITH A SPAN <br />RATING OF 24/0 WITH 8D NAILS AT 6" O/C AT EDGES AND BOUNDARIES AND 12" O/C <br />FIELD NAILING. <br />12.FLOOR SHEATHING SHALL BE 23/32" APA RATED SHEATHING EXP 1 WITH A MINIMUM <br />SPAN RATING OF 48/24 WITH 10D NAILS AT 6" O/C AT EDGES AND BOUNDARIES AND 10" <br />O/C FIELD NAILING. <br />FOUNDATION <br />1.THE FOUNDATION DESIGN IS BASED UPON CHAPTER 4 C.R.C. THE CONTRACTOR <br />SHALL BE RESPONSIBLE FOR ALL REQUIREMENTS THEREIN AND MAINTAIN A COPY <br />ON THE JOB SITE AT ALL TIMES. <br />2.THE ENGINEER OF RECORD MUST BE INFORMED OF ANY CHANGES IN DESIGN <br />CRITERIA MADE BY ANY SOILS GEOLOGIST IN THE COURSE OF CONSTRUCTION. <br />3.ALL FOOTINGS AND SLABS SHALL BE FOUNDED ON FIRM UNDISTURBED NATURAL <br />SOILS OR APPROVED COMPACTED FILL. CONTRACTOR TO PROVIDE BUILDING <br />INSPECTOR WITH COMPACTION REPORTS AND/OR WRITTEN APPROVAL OF <br />COMPACTED FILL FROM A SOIL GEOLOGIST FOR ANY REQUIRED FILL. <br />4.ALL COMPACTED FILL SHALL BE PLACED IN AN APPROVED MANNER WITH A MINIMUM <br />DENSITY OF 90% OF THE MAXIMUM OBTAINABLE IN ACCORDANCE WITH ASTM D 1557. <br />5.ALL FOUNDATION EXCAVATIONS, FILLING, BACK FILLING, AND BUILDING PADS SHALL <br />BE INSPECTED AND APPROVED BY THE CITY BUILDING INSPECTOR BOTH PRIOR TO, <br />AND AFTER PLACEMENT OF REINFORCEMENT. THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR ALL SHORING NECESSARY TO SUPPORT CUT AND/OR FILL <br />SECTIONS DURING EXCAVATION AND FOR FORMING AND PLACEMENT OF CONCRETE. <br />6.THE CONTRACTOR SHALL INFORM THE ARCHITECT AND ENGINEER OF THE LOCATION <br />OF EXISTING UTILITIES AND COMMENCE WORK ONLY AFTER WRITTEN APPROVAL <br />FROM THE ARCHITECT. <br />7.ALL RETAINING WALLS HAVE BEEN DESIGNED AS A FREE DRAINING CONDITION. <br />DESIGN FOR THE DRAINAGE SYSTEM SHALL BE BY OTHERS AND SHALL MEET THE <br />REQUIREMENTS OF THE SOILS REPORT.BACK FILL AGAINST WALLS SHALL BE PLACED <br />EVENLY AGAINST BOTH SIDES OF WALLS UNTIL THE LOWER GRADE IS REACHED. <br />8.FOOTING WITH MINIMUM REINFORCEMENT OF: 2#4 @ TOP & 2#4 @ BOTTOM. OR U.N.O <br />9.EXISTING FOOTING : USE EPOXY FOR A.B. WITH SAME LENGTH AS REGULAR BOLTS <br />WITH SPECIAL INSPECTION. <br />GENERAL <br />1.ALL CONCRETE MASONRY MATERIALS AND CONSTRUCTION SHALL BE IN <br />ACCORDANCE WITH BUILDING CODE, CHAPTER 21. <br />MATERIALS <br />2.ALL MATERIALS MAKING UP FINISHED CONCRETE MASONRY CONSTRUCTION SHALL <br />CONFORM TO STANDARDS REQUIRED BY BUILDING CODE SEC. 2103. <br />3.MORTAR SHALL BE TYPE M OR S AS APPLICABLE AND CONFORMING WITH ASTM C270 <br />AND SHALL BE PROPORTIONED PER ARTICLE 2.1 & 2.6A OF SPECIFICATION FOR <br />MASONRY STRUCTURES (TMS 602-16). <br />4.GROUT SHALL COMPLY WITH ARTICLE 2.2 OF TMS 602-16 AND SHALL ATTAIN A <br />MINIMUM COMPRESSION STRENGTH AT 28 DAYS OF 1500 PSI OR THE REQUIRED <br />COMPRESSION, F'M, WHICHEVER IS GREATER. THE COMPRESSIVE STRENGTH OF <br />GROUT SHALL BE DETERMINED IN ACCORDANCE WITH ASTM C-1019. <br />5.CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 FOR LOAD BEARING <br />CONCRETE MASONRY UNITS. CONCRETE BRICK SHALL CONFORM TO ASTM C55, <br />SPECIFICATIONS FOR CONCRETE BUILDING BRICK. <br />6.GRADE N CONCRETE BRICKS ARE FOR USE AS ARCHITECTURAL VENEER AND <br />FACING, LIMITED TO IN EXTERIOR WALLS. <br />7.GRADE S CONCRETE BRICKS ARE FOR GENERAL USE WHERE MODERATE STRENGTH <br />AND RESISTANCE TO FROST ACTION AND MOISTURE PENETRATION IS REQUIRED. <br />STRENGTH <br />8.THE SPECIFIED COMPRESSIVE STRENGTH OF MASONRY, F'M, SHALL BE 2000 PSI, <br />UNLESS NOTED OTHERWISE. IF HIGHER F'M IS NOTED, IT SHALL BE VERIFIED BY <br />PRISM TESTS AS REQUIRED IN ARTICLE 1.4 SPECIFICATION OF MASONRY <br />STRUCTURES (TMS 602-16). <br />9.REINFORCING STEEL SHALL CONFORM TO ASTM A615. GRADE 40 FOR SIZES #3 AND <br />GRADE 60 FOR SIZES #4 AND LARGER. <br />SPECIAL INSPECTION <br />10.SPECIAL INSPECTION FOR CONCRETE MASONRY CONSTRUCTION SHALL BE CARRIED <br />OUT IN ACCORDANCE WITH BUILDING CODE SECTION 1704 AND REQUIREMENTS IN <br />SPECIAL INSPECTION TABLES ON SHEET SN-1. MASONRY COMPRESSIVE STRENGTH, <br />F'M SHALL BE VERIFIED BY UNIT STRENGTH METHOD OR PRISM TEST METHOD PRIOR <br />TO AND DURING CONSTRUCTION AS DESCRIBED IN ARTICLE 1.4 SPECIFICATION FOR <br />MASONRY STRUCTURES (TMS 602-16). <br />1.SOILS <br />SOILS ALLOWABLE DESIGN VALUES IS 1500 PSF, <br />2.BUILDING CODE - 2022 CALIFORNIA BUILDING CODE <br />3.DESIGN LOADS: <br />4.LATERAL LOADS: <br />ROOF LOAD <br />DEAD LOAD = 16 PSF <br />LIVE LOAD = 20 PSF <br />TOTAL = 36 PSF <br />RISK CATEGORY: II <br />SEISMIC DESIGN CATEGORY: D <br />SEISMIC IMPORTANCE FACTOR (I) = 1.0 <br />SITE CLASS = D-Default <br />WIND SPEED:110 MPH <br />WIND EXPOSURE:C <br />Ss:1.306 <br />S1:0.465 <br />Csy:0.113 <br />Ry:6.5 <br />Csx:0.113 <br />RX: 6.5 <br />DESIGN CRITERIA <br />SILL PLATE <br />NAILING <br />(16D SINKER) <br />SHEAR WALL SCHEDULE: <br />TYPE SHEAR PANEL <br /> 1 260 PLF 3/8" APA STRUCT. RATED PLYWOOD(or OSB) <br />WITH 8d COMMON NAILS AT 6" O.C. EDGES <br />AND 12" O.C. FIELD <br /> 2 380 PLF <br /> 3 490 PLF <br /> 4 640 PLF <br />3/8" APA STRUCT. RATED PLYWOOD(or OSB) <br />WITH 8d COMMON NAILS AT 4" O.C. EDGES <br />AND 12" O.C. FIELD <br />3/8" APA STRUCT. RATED PLYWOOD(or OSB) <br />WITH 8d COMMON NAILS AT 3" O.C. EDGES <br />AND 12" O.C. FIELD <br />3/8" APA STRUCT. RATED PLYWOOD(or OSB) <br />WITH 8d COMMON NAILS AT 2" O.C. EDGES <br />AND 12" O.C. FIELD <br /> 5 800 PLF <br />15/32" APA STRUCT I. RATED PLYWOOD <br />WITH 10d COMMON NAILS AT 2" O.C. EDGES <br />AND 12" O.C. FIELD <br />6" O.C., OR <br />A35 @ 24" O.C. <br />4" O.C., OR <br />A35 @ 16" O.C. <br />3" O.C., OR <br />A35 @ 12" O.C. <br />2" O.C., OR <br />A35 @ 10" O.C. <br />(2)3" O.C., OR <br />A35 @ 6" O.C. <br />FRAMING CLIP <br />A35's,LS50's <br />OR LTP4's. <br />16" O.C. <br />12" O.C. <br />8" O.C. <br />6" O.C. <br />5" O.C. <br />SHEET INDEX <br />No.SHEET NO.SHEET NAME <br />1 S0.0 - GENERAL STRUCTURAL NOTES. <br />2 S0.1 - TYPICAL DETAILS. <br />3 S1.0 - FOUNDATION PLAN & FRAMING PLAN. <br />4 SD1 - STRUCTURAL DETAILS. <br />BASIC SEISMIC FORCE RESISTING SYSTEM: PLYWOOD SHEAR WALL <br />ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE <br />FLOOR LOAD <br />DEAD LOAD = 15 PSF <br />LIVE LOAD = 40 PSF <br />TOTAL = 55 PSF <br />PDC <br />Pr <br />o <br />j <br />e <br />c <br />t <br /> <br />A <br />d <br />d <br />r <br />e <br />s <br />s <br />: <br /> <br /> <br />2 <br />2 <br />0 <br />1 <br /> <br />W <br /> <br />7 <br />t <br />h <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br /> <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />. <br />SHEET NO.: <br />DRAW BY: <br />DUY NGUYEN <br />PLOTE DATE: <br />JOB NO.: 24058 <br />C 69546 <br />Exp: 06/30/26 <br />TUNG THANH VO <br />C I V I LSTATE OF CALIFORNIA <br />REGISTERED PROFESSIONAL ENGINEER <br />07/15/2024 <br />GE <br />N <br />E <br />R <br />A <br />L <br />ST <br />R <br />U <br />C <br />T <br />U <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S <br />S0.0 <br />2201 W Seventh St <br />12/9/2024