Template:
Plan
Permit Number
20183818
20184054
101120572
Full Address
222 S Spruce St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
FROM PV MODULES TO JBOX <br />FROM JBOX TO INVERTER <br />(2)1 <br />(1) #6 AWG BARE CU EGC, <br />2 <br /> #8 AWG CU EGC, <br />(3) <br />3 <br />(1) #8 AWG CU EGC, <br /> MAXIMUM INVERTER OUTPUT CURRENT (A) <br /> TEMPERATURE FACTOR <br /> TEMPERATURE ADJUSTMENT (A) <br />OUTPUT CALCULATIONS <br />PV SYSTEM MAX DC OUTPUT <br />PV SYSTEM MAX AC OUTPUT <br /> MAXIMUM POWER (W) <br /> PEAK PWR TRACKING VOLTAGE (V) <br /> CONSIDER CONTINUOUS COEFFICIENT <br /> SHORT CIRCUIT CURRENT (A) <br /> ADJUSTED CONDUCTOR AMPACITY (A) <br />1.25 <br />1.25 <br />1.25 <br />0.91 <br />(2) <br />(1) <br /> Pmax (PTC Rating) <br />25.0 <br />380 <br />1 99 % <br />25.0 * 1.25 / 0.91 34.4 <br /> #8 AWG THWN-2 <br />40A SOLAR EDGE SE6000H-US (240V) <br />25.0 * 1.25 31.3 <br />1 1/2'' <br /> (TEMP - 39 + 22 = 61C)0.58 <br /> RACEWAY HEIGHT FROM ROOF <br />ADJST. FACTOR (1 thru 3 WIRES)1.0 <br />FREE IN THE AIR, 3/4'' EMT TYPE CONDUIT BETWEEN ARRAYS <br />3/4'' EMT TYPE CONDUIT <br />1'' EMT TYPE CONDUIT <br />MAIN SERVICE PANEL RATING <br />BUSBAR RATING <br />MAIN BREAKER <br />PV BACKFEED BREAKER SIZE <br />120% RULE: <br />MAX ALLOWED FEED <br />40A <br />*/*1.25 *1.2512 395 380 19.5 <br />/ /19.5 0.58 1.0 33.6 <br />#10 AWG THWN-2 <br />WIRE CHART WIRE CHART <br /> *12 395 4.74 KW <br />* *12 371.9 0.99 4.42 KW <br /> CONSIDER CONTINUOUS COEFFICIENT <br /> CONSIDER CONTINUOUS COEFFICIENT <br />200A <br />200A <br />240A <br />200A ''MB'' + 40A "SOLAR" = 240A ≤ 240A MAX <br />FROM INVERTER TO MAIN SERVICE PANEL <br /> CONSIDER CONTINUOUS (A) <br /> MAX NUMBER OF MODULES IN STRING 12 <br />#10 AWG PV-WIRE <br />12 <br />CS6R-395MS-HL 395 W <br />371.9 W <br />395 <br />WIRE SIZE <br />CALCULATIONS <br />PV SYSTEM <br />AS INDICATED <br />May 2, 2024 <br />ROSENDO TORRES <br />222 S SPRUCE ST, <br />SANTA ANA, CA 92703 <br />Clean Energy Solutions Inc. <br />Address: <br />1055 West 7th Street <br />33rd Floor, Los Angeles, <br />CA 90017 <br />Phone Number: <br />(800) 994 1134 <br />Lic# 998787 <br />Class C-10 <br />CONTRACTOR <br />Designed By: Intersolar CAD <br />www.intersolarcad.com <br />PV SYSTEM DC SIZE 4.74KW <br />PV SYSTEM AC SIZE 4.42KW <br />E 1.1 <br />222 S Spruce St <br />9/12/2024