Laserfiche WebLink
A1-PANEL <br />PER SCHED. <br />PE <br />R <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />BSINGLE-LITE <br />PER SCHED. <br />PE <br />R <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />C2 PANEL CLOSET SLIDER <br />PER SCHED. <br />PE <br />R <br /> <br />S <br />C <br />H <br />E <br />D <br />U <br />L <br />E <br />ASINGLE <br />HUNGBHORIZONTAL SLIDER <br />PER SCHED. <br />PE <br />R <br /> <br />S <br />C <br />H <br />E <br />D <br />. <br />SE <br />E <br /> <br />E <br />L <br />E <br />V <br />PER SCHED. <br />PE <br />R <br /> <br />S <br />C <br />H <br />E <br />D <br />. <br />SE <br />E <br /> <br />E <br />L <br />E <br />V <br />PER SCHED. <br />PE <br />R <br /> <br />S <br />C <br />H <br />E <br />D <br />. <br />SE <br />E <br /> <br />E <br />L <br />E <br />V <br />CHORIZONTAL SLIDER <br />PA / PM: <br />DRAWN BY: <br />PROJECT NUMBER: <br />TH <br />E <br />S <br />E <br /> <br />D <br />R <br />A <br />W <br />I <br />N <br />G <br />S <br /> <br />A <br />N <br />D <br /> <br />S <br />P <br />E <br />C <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />S <br /> <br />A <br />R <br />E <br /> <br />T <br />H <br />E <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />A <br />N <br />D <br /> <br />C <br />O <br />P <br />Y <br />R <br />I <br />G <br />H <br />T <br /> <br />O <br />F <br /> <br />M <br />O <br />I <br />R <br />E <br /> <br />S <br />T <br />U <br />D <br />I <br />O <br /> <br />A <br />N <br />D <br /> <br />S <br />H <br />A <br />L <br />L <br /> <br />N <br />O <br />T <br /> <br />B <br />E <br /> <br />U <br />S <br />E <br />D <br /> <br />O <br />N <br /> <br />A <br />N <br />Y <br /> <br />O <br />T <br />H <br />E <br />R <br /> <br />W <br />O <br />R <br />K <br /> <br />E <br />X <br />C <br />E <br />P <br />T <br /> <br />B <br />Y <br /> <br />A <br />G <br />R <br />E <br />E <br />M <br />E <br />N <br />T <br /> <br />W <br />I <br />T <br />H <br /> <br />M <br />O <br />I <br />R <br />E <br /> <br />S <br />T <br />U <br />D <br />I <br />O <br /> <br />W <br />R <br />I <br />T <br />T <br />E <br />N <br /> <br />D <br />I <br />M <br />E <br />N <br />S <br />I <br />O <br />N <br />S <br /> <br />S <br />H <br />A <br />L <br />L <br /> <br />T <br />A <br />K <br />E <br /> <br />P <br />R <br />E <br />F <br />E <br />R <br />E <br />N <br />C <br />E <br /> <br />O <br />V <br />E <br />R <br /> <br />S <br />C <br />A <br />L <br />E <br />D <br /> <br />D <br />I <br />M <br />E <br />N <br />S <br />I <br />O <br />N <br />S <br /> <br />A <br />N <br />D <br /> <br />S <br />H <br />A <br />L <br />L <br /> <br />B <br />E <br /> <br />V <br />E <br />R <br />I <br />F <br />I <br />E <br />D <br /> <br />O <br />N <br /> <br />T <br />H <br />E <br /> <br />J <br />O <br />B <br /> <br />S <br />I <br />T <br />E <br />. <br /> <br />A <br />N <br />Y <br /> <br />D <br />I <br />S <br />C <br />R <br />E <br />P <br />A <br />N <br />C <br />Y <br /> <br />S <br />H <br />A <br />L <br />L <br /> <br />B <br />E <br /> <br />B <br />R <br />O <br />U <br />G <br />H <br />T <br /> <br />T <br />O <br /> <br />T <br />H <br />E <br /> <br />N <br />O <br />T <br />I <br />C <br />E <br /> <br />O <br />F <br /> <br />M <br />O <br />I <br />R <br />E <br /> <br />S <br />T <br />U <br />D <br />I <br />O <br /> <br />P <br />R <br />I <br />O <br />R <br /> <br />T <br />O <br /> <br />T <br />H <br />E <br /> <br />C <br />O <br />M <br />M <br />E <br />N <br />C <br />E <br />M <br />E <br />N <br />T <br /> <br />O <br />F <br /> <br />A <br />N <br />Y <br /> <br />W <br />O <br />R <br />K <br />. <br />TN/TB <br />TB <br />24006 <br />architect's stamp: <br />consultant's stamp: <br />NO.DATE SUBMITTAL <br />1 04-29-2024 PLAN CHECK SUBMITTAL <br />2001 S BIRCH STREET, <br />SANTA ANA, CA 92707 <br />RESTORATION <br />BIRCH ST <br />THE <br />2125 Ocean Park Boulevard <br />Santa Monica, CA 90405 <br />Tel: 949 395 1718 <br />2 06-26-2024 PC CORRECTIONS 1 <br />3 07-09-2024 PC CORRECTIONS 2 <br />4 08-19-2024 PC CORRECTIONS 3 <br />C-35111 <br />REN. 2/28/2025 <br />5 09-13-2024 PC CORRECTIONS 4 <br />A10.1 <br />SCHEDULES <br />SECURITY NOTES: <br />1.ALL SECURITY OPENINGS ARE IDENTIFIED BY AN ASTERISK (*) <br />SYMBOL ON THE SCHEDULES. <br />2.PROVIDE DOOR VIEWERS, VIEW PORTS, OR VIEWING <br />WINDOWS FOR HOUSE FRONT DOOR OR GUEST ROOM <br />ENTRANCE DOORS (SEE ALSO 91.6720). <br />3.DETAILS AND SPECIFICATIONS FOR ALL SWINGING DOORS <br />IN SECURITY OPENINGS SHALL BE IN ACCORDANCE WITH <br />THE FOLLOWING REQUIREMENTS: <br />4.WOOD FLUSH DOORS SHALL BE A MINIMUM 1 3/8" THICK <br />WITH SOLID CORE CONSTRUCTION. <br />5.HOLLOW CORE DOORS OR DOORS LESS THAN A 1 3/8" IN <br />THICKNESS SHALL BE COVERED ON THE INSIDE FACE <br />WITH 16 GAUGE SHEET METAL ATTACHED WITH SCREWS AT <br />6" ON CENTER AROUND PERIMETER. <br />6.WOOD PANEL TYPE DOORS SHALL HAVE PANELS <br />FABRICATED OF NOT LESS 9/16" INCH THICKNESS, <br />PROVIDED THE SHAPED PORTIONS OF THE PANEL ARE NOT <br />LESS THAN 1/4" THICK. INDIVIDUAL PANEL SHALL NOT <br />EXCEED 300 SQ. INCHES IN AREA. STILES AND RAILS SHALL <br />BE OF SOLID LUMBER WITH OVERALL DIMENSIONS OF NOT <br />LESS THAN 1 3/8" AND 3" IN WIDTH. MULLIONS SHALL BE <br />CONSIDERED A PART OF ADJACENT PANELS UNLESS SIZED <br />AS REQUIRED HEREIN FOR STILES AND RAILS EXCEPT <br />MULLIONS NOT OVER 18" LONG MAY HAVE AN OVERALL <br />WIDTH OF NOT LESS THAN 2". <br />7.GLAZED OPENINGS, WITHIN 40" OF THE DOOR LOCK WHEN <br />THE DOOR IS IN THE CLOSED POSITION, SHALL BE FULLY <br />TEMPERED GLASS OR APPROVED BURGLARY RESISTANT <br />MATERIAL, OR SHALL BE PROTECTED BY METAL BARS, <br />SCREENS OR GRILLS HAVING A MAXIMUM OPENING OF 2". <br />PROVISIONS IN THIS SECTION SHALL NOT APPLY TO <br />VIEWPORTS OR WINDOWS WHICH DO NOT EXCEED 2" IN <br />THEIR GREATEST DIMENSIONS. 91.6720 <br />8.DOOR STOPS OF IN-SWINGING DOORS SHALL BE OF ONE <br />PIECE CONSTRUCTION WITH JAMB OR JOINED RABBET TO <br />THE JAMB. <br />9.ALL PIN TYPE HINGES WHICH ARE ACCESSIBLE FROM <br />OUTSIDE THE SECURED AREA WHEN THE DOOR IS CLOSED <br />SHALL HAVE NON-REMOVABLE HINGE PINS. IN ADDITION <br />THEY SHALL HAVE 1/4" DIAMETER STEEL JAMB STUD WITH <br />1/4" MINIMUM PROTECTION UNLESS THE HINGES ARE <br />SHAPED TO PREVENT REMOVAL OF THE DOOR IF THE <br />HINGE PINS ARE REMOVED. <br />10.THE STRIKE PLATES FOR HINGES AND THE HOLDING DEVICE <br />FOR PROTECTED DEAD BOLTS IN WOOD CONSTRUCTION <br />SHALL BE SECURED TO THE JAMB AND THE WALL FRAMING <br />WITH SCREWS NOT LESS THAN 2 1/2" IN LENGTH. 91.6711 <br />(G) <br />11.DEAD BOLTS WITH HARDENED INSERTS SHALL BE INSTALLED <br />UNDER THE FOLLOWING CONDITIONS: DEADLOCKING <br />LATCH KEY-OPERATED LOCKS ON EXTERIOR; LOCKS <br />OPERABLE WITHOUT KEY, SPECIAL KNOWLEDGE OR <br />SPECIAL EFFORT ON INTERIOR; AND TYPE THROW AND <br />EMBEDMENT OF DEAD BOLTS FOR SINGLE SWINGING <br />DOOR, ACTIVE LEAF OR PAIRS OF DOORS, OR BOTTOM <br />LEAF OF DUTCH DOOR. <br />12.STRAIGHT DEAD BOLTS SHALL HAVE A MINIMUM THROW <br />OF 1" AND AN EMBEDMENT OF NOT LESS THAN 5/8". <br />91.6711 (B) <br />13.A HOOK SHAPED OR EXPANDING-LUG DEAD BOLT SHALL <br />HAVE A MINIMUM THROW OF 3/4". 91.6711 (B) <br />14.CYLINDER GUARDS SHALL BE INSTALLED ON ALL CYLINDER <br />LOCKS WHENEVER THE CYLINDER PROJECTS BEYOND THE <br />FACE OF THE DOOR OR IS OTHERWISE ACCESSIBLE TO <br />GRIPPING TOOLS. 91.6711 (F) <br />15.SHOW MEANS OF SECURING INACTIVE LEAF OF DOUBLE <br />DOOR AND UPPER LEAF OF DUTCH DOOR. 91.6711 (B) <br />16.SLIDING GLASS DOORS AND WINDOWS SHALL BE <br />EQUIPPED WITH LOCKING DEVICES AND AND SHALL BE <br />SO CONSTRUCTED THAT THEY REMAIN INTACT AND <br />ENGAGED WHEN SUBJECTED TO THE TESTS SPECIFIED IN <br />91.6731 AND 91.6732. <br />17.SLIDING DOORS AND WINDOWS SHALL BE PROVIDED WITH <br />A DEVICE IN THE UPPER CHANNEL OF THE MOVING PANEL <br />IN THE CLOSED OR PARTIALLY OPEN POSITION. <br />18.PROVIDE AN ALARM FOR THE DOORS TO THE DWELLING <br />THAT FORM A PART OF THE POOL ENCLOSURE. THE ALARM <br />SHALL SOUND CONTINUOUSLY FOR A MINIMUM OF 30 <br />SECONDS WHEN THE DOOR IS OPENED. IT SHALL <br />AUTOMATICALLY RESET AND BE EQUIPPED WITH A <br />MANUAL MEANS TO DEACTIVATE (FOR 15 SECONDS <br />MAXIMUM) FOR A SINGLE OPENING. THE DEACTIVATION <br />SWITCH SHALL BE AT LEAST 54" ABOVE THE FLOOR. P/BC <br />2001-14. <br />19.SCREEN BARRICADES, OR FENCES MADE OF MATERIAL <br />WHICH PRECLUDE HUMAN CLIMBING SHALL BE PROVIDED <br />AT EVERY PORTION OF EVERY ROOF, BALCONY OR <br />SIMILAR SURFACE WHICH IS WITHIN 8' OF THE UTILITY POLE <br />OR SIMILAR STRUCTURE. <br />20.EGRESS DOORS SHALL BE READILY OPENABLE FROM THE <br />EGRESS SIDE W/OUT THE USE OF A KEY OR ANY SPECIAL <br />KNOWLEDGE OR EFFORT. CBC 1008.1.8 <br />GENERAL DOOR NOTES: <br />1. REFER TO DOOR SCHEDULE FOR EXACT SPECIFICATIONS & <br />NOTES. <br />2. ALL DOOR DIMENSIONS ARE APPROXIMATE ONLY. <br />ACTUAL DIMENSIONS MUST BE DETERMINED AND VERIFIED <br />ON-SITE. GC TO VERIFY SIZES OF ALL WINDOWS AND <br />ROUGH OPENINGS PRIOR TO PURCHASE OF ANY UNITS. <br />3. VERIFY ALL SIZES ON SCHEDULE WITH ELEVATIONS. <br />4. GLAZING CERTIFICATE MUST ACCOMPANY GLAZING <br />PRODUCTS & STATE THAT THE PRODUCT CONFORMS WITH <br />THE APPLICABLE CONSUMER PRODUCT SAFETY <br />STANDARDS AND SHALL CLEARLY STATE THE NAME OF THE <br />MANUFACTURER. <br />5. GC TO VERIFY THAT ALL GLAZING CORRESPONDS TO TITLE <br />24 REQUIREMENTS. <br />6. ALL GLAZING IN HAZARDOUS LOCATIONS SHALL BE <br />TEMPERED. SEE GLAZING NOTES FOR SPECIFIC <br />LOCATIONS. <br />7. ALL ALUMINUM DOORS TO BE TO BE MANUFACTURED BY <br />A SINGLE MANUFACTURER. WESTERN INTEGRATED OR <br />APPROVED EQUAL. <br />8. FINISH DOORS TO MATCH ARCHITECTS SAMPLE. PROVIDE <br />(3) SAMPLES FOR ARCHITECT'S APPROVAL. <br />9. UNDERCUT OF ALL DOORS TO BE NO MORE THAN 1" <br />ABOVE THRESHOLD OR FINISH FLOOR. GC TO CONFIRM <br />HEIGHT OF ALL FINISH FLOORS BEFORE ORDERING & <br />INSTALLATION OF ANY DOORS. <br />10. BOTTOM 10" OF DOORS TO BE SMOOTH & UNINTERRUPTED. <br />11. PROVIDE DOOR STOPS THROUGHOUT. VERIFY PLACEMENT <br />OF STOPS W/ ARCHITECT FOR ALL DOORS OPENING MORE <br />THAN 90 DEG. <br />12. SET FRAMES ACCURATELY IN POSITION, PLUMBED, <br />ALIGNED & BRACED SECURELY PRIOR TO WALL FRAME <br />CONSTRUCTION & UNTIL PERMANENT ANCHORS ARE SET. <br />AFTER WALL CONSTRUCTION IS COMPLETE, REMOVE <br />TEMPORARY BRACES & SPREADERS LEAVING SURFACES <br />SMOOTH & UNDAMAGED. PROVIDE UNIFORM & <br />MINIMUM CLEARANCES FOR ALL DOORS. <br />13. VERIFY TYPE HARDWARE THROUGHOUT. <br />14. GC SHALL BE RESPONSIBLE FOR ARRANGING HIS WORK & <br />SECURING DELIVERY OF ALL HARDWARE, SO THAT ALL <br />WORK SHALL PROGRESS WITHOUT DELAY & INTERRUPTION. <br />15. GC SHALL INSTALL FINISH HARDWARE AS REQUIRED. <br />HARDWARE SHALL BE FITTED PRIOR TO <br />PAINTING/STAINING, AND THEN REMOVED. FINAL <br />PAINTING/STAINING SHALL BE COMPLETED BEFORE FINAL <br />INSTALLATION OF HARDWARE. <br />16. PLACE FIRE-RATED FRAMES IN ACCORDANCE W/ NFPA <br />STANDARD NO. 80 & IN ACCORDANCE W/ <br />MANUFACTURER'S FIRE TEST REPORT INSTALLATION DATA. <br />17. ALL WOOD DOORS TO BE PREFINISHED, CLEAR SEALED <br />----------- UNO. STAIN COLOR TO MATCH MILLWORK FINISH <br />-----. PROVIDE (3) SAMPLES FOR ARCHITECT'S APPROVAL. <br />SECURITY REQUIREMENTS: <br />1. PROVIDE MULTI-POINT MEANS OF SECURING INACTIVE <br />LEAF OF DOUBLE DOORS & UPPER LEAF OF DUTCH DOOR. <br />91.6711 <br />2. ALL GLASS DOORS TO HAVE FULLY TEMPERED GLASS <br />COMPLYING W/ 91.6711. SEE GLAZING NOTES FOR <br />SPECIFIC REQUIREMENTS. <br />GENERAL WINDOW NOTES: <br />1. REFER TO WINDOW SCHEDULE FOR EXACT <br />SPECIFICATIONS & NOTES. <br />2. ALL WINDOWS TO BE WESTERN INTEGRATED OR <br />APPROVED EQUAL. <br />3. ALL WINDOW DIMENSIONS ARE APPROXIMATE ONLY. <br />ACTUAL DIMENSIONS MUST BE DETERMINED AND VERIFIED <br />ON-SITE. GC TO VERIFY SIZES OF ALL WINDOWS AND <br />ROUGH OPENINGS PRIOR TO PURCHASE OF ANY UNITS. <br />4. VERIFY ALL SIZES ON SCHEDULE WITH ELEVATIONS. <br />5. GLAZING CERTIFICATE MUST ACCOMPANY GLAZING <br />PRODUCTS & STATE THAT THE PRODUCT CONFORMS WITH <br />THE APPLICABLE CONSUMER PRODUCT SAFETY <br />STANDARDS AND SHALL CLEARLY STATE THE NAME OF THE <br />MANUFACTURER. <br />6. GLASS EDGE CLEARANCE IN FIXED OPENINGS SHALL NOT <br />BE LESS THAN REQUIRED FOR WIND & EARTHQUAKE DRIFT. <br />7. GC TO VERIFY THAT ALL GLAZING CORRESPONDS TO TITLE <br />24 REQUIREMENTS. <br />8. ALL GLAZING IN HAZARDOUS LOCATIONS SHALL BE <br />TEMPERED. SEE GLAZING NOTES FOR SPECIFIC <br />GLAZING NOTES: <br />EACH PANE OF SAFETY GLAZING INSTALLED IN HAZARDOUS <br />LOCATIONS SHALL BE IDENTIFIED BY A MANUFACTURERS <br />DESIGNATION SPECIFYING WHO APPLIED THE DESIGNATION, THE <br />MANUFACTURER OR INSTALLER AND THE SAFETY GLAZING <br />STANDARD. THE FOLLOWING SHALL BE CONSIDERED SPECIFIC <br />HAZARDOUS LOCATIONS FOR THE PURPOSED OF SAFETY <br />GLAZING. GLAZING IN: SECTION 2406 <br />a.SWING DOORS. <br />b.FIXED AND SLIDING PANELS OF SLIDING DOOR ASSEMBLIES <br />AND PANELS IN SLIDING AND BI-FOLD CLOSET DOOR <br />ASSEMBLIES. <br />c.STORM DOORS. <br />d.UNFRAMED SWINGING DOORS. <br />e.DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, <br />SAUNAS, STEAM ROOMS, BATHTUBS, AND SHOWERS. <br />f.FIXED OR OPERABLE PANELS ADJACENT TO A DOOR <br />WHERE THE NEAREST EXPOSED EDGE OF THE GLAZING IS WITHIN <br />24 INCHES (610 MM) ARC OF EITHER VERTICAL EDGE OF THE <br />DOOR IN A CLOSED POSITION AND WHERE THE BOTTOM <br />EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 INCHES <br />(1,525 MM) ABOVE THE WALKING SURFACE. READ CODE <br />FOR EXCEPTIONS. <br />g.FIXED OR OPERABLE PANEL, OTHER THAN DESCRIBED IN <br />ITEMS E AND F, WHICH MEETS ALL OF THE FOLLOWING <br />CONDITIONS (READ CODE FOR EXCEPTION WITH SPECIAL <br />INSTALLATION). <br />i.EXPOSED AREA OF AN INDIVIDUAL PANE GREATER THAN 9 <br />SQUARE FEET (0.84 M2 ) <br />ii.EXPOSED BOTTOM EDGE LESS THAN 18 INCHES (457 MM) <br />ABOVE THE FLOOR. <br />iii.EXPOSED TOP EDGE GREATER THAN 36 INCHES (914 MM) <br />ABOVE THE FLOOR. <br />iv.ONE OR MORE WALKING SURFACES WITHIN 36 INCHES <br />(914 MM) HORIZONTALLY OF THE PLANE OF THE GLAZING. <br />h.GUARDS AND RAILINGS REGARDLESS OF AREA OR HEIGHT <br />ABOVE A WALKING SURFACE. INCLUDED ARE STRUCTURAL <br />BALUSTER PANELS AND NONSTRUCTURAL IN-FILL PANELS. <br />i.WALLS AND FENCES ENCLOSING INDOOR AND OUTDOOR <br />SWIMMING POOLS AND SPAS WHERE ALL OF THE FOLLOWING <br />CONDITIONS ARE PRESENT: <br />i.THE BOTTOM EDGE OF THE GLAZING IS LESS THAN 60 <br />INCHES (1,525 MM) ABOVE A WALKING SURFACE ON <br />THE POOL OR SPA SIDE OF THE GLAZING. <br />ii.THE GLAZING IS WITHIN 60 INCHES (1,525 MM) OF A <br />SWIMMING POOL OR SPA WATERS EDGE. <br />j.ADJACENT TO STAIRWAYS, LANDINGS AND RAMPS WITHIN <br />36 INCHES HORIZONTALLY OF A WALKING SURFACE; WHEN THE <br />EXPOSED SURFACE OF THE GLASS IS LESS THAN 60 INCHES <br />ABOVE THE PLANE OF THE ADJACENT WALKING SURFACE(READ <br />CODE FOR EXCEPTION WITH SPECIAL INSTALLATION). <br />k.ADJACENT TO STAIRWAYS WITHIN 60 INCHES <br />HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY IN ANY <br />DIRECTION WHEN THE EXPOSED SURFACE OF THE GLASS IS LESS <br />THAN 60 INCHES ABOVE THE NOSE OF THE TREAD (READ CODE <br />FOR EXCEPTION WITH SPECIAL INSTALLATION). <br />DOOR TYPES <br />SCALE: 1/4" = 1'-0" <br />1 <br />WINDOW TYPES <br />SCALE: 1/4" = 1'-0" <br />2 <br />NOTE: GC TO VERIFY THE OPERABLE DIRECTION OF ALL WINDOWS WITH BUILDING ELEVATIONS PRIOR TO ORDERING UNITS <br />NOTE: GC TO VERIFY THE OPERABLE DIRECTION OF ALL DOORS WITH FLOOR PLANS PRIOR TO ORDERING UNITS <br />WINDOW SCHEDULE <br />I.D.LOCATION <br />WINDOW FRAME <br />DU <br />A <br />L <br />LA <br />M <br />I <br />N <br />A <br />T <br />E <br />D <br />LO <br />W <br />- <br />E <br />TE <br />M <br />P <br />E <br />R <br />E <br />D <br />FIRE OR <br />STC <br />RATING <br />HARD- <br />WARE <br />GROUP <br />DETAILS <br />TYPE UNIT SIZE (W X H)MATERIAL FINISH HEAD JAMB SILLWALL <br />DEPTH <br />SC <br />R <br />E <br />E <br />N <br />U-FACTOR SHGC <br />W101 BEDROOM 101 A 4'-0" X 5'-0" V.I.F.PER PLN.VINYL TBD ----0.29 0.20 (E) CONTRACTOR TO VERIFY HEIGHT & SIZE ALIGNS WITH (E) <br />I.D.LOCATION <br />DOOR <br />DOOR SCHEDULE <br />FRAME <br />DU <br />A <br />L <br />LA <br />M <br />I <br />N <br />A <br />T <br />E <br />D <br />LO <br />W <br />- <br />E <br />SC <br />R <br />E <br />E <br />N <br />FIRE OR <br />STC <br />RATING <br />HARD- <br />WARE <br />GROUP <br />CLOSER <br />DETAILS <br />REMARKS <br />TYPE UNIT SIZE (W X H)THK.MATERIAL FINISH MATERIAL FINISH HEAD JAMB SILL <br />1011 BEDROOM 101 A 2'-8" X 6'-8" V.I.F.--TBD TBD TBD TBD -------- <br />TE <br />M <br />P <br />E <br />R <br />E <br />D <br />U-FACTOR SHGC <br />W102 BEDROOM 101 A 3'-4" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />W103 BEDROOM 101 A 3'-4" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />W104 (E) KITCHEN 102 B 4'-4" X 3'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />W105 (E) BEDROOM 103 A 2'-6" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />W106 (E) BEDROOM 103 A 2'-6" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />W107 (E) BEDROOM 103 A 2'-6" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />W108 (E) MASTER BATH 105 C 2'-0" X 2'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />'' "W109 (E) MASTER BEDROOM 106 A 2'-6" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />'' "W110 (E) MASTER BEDROOM 106 A 2'-6" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />'' "W111 (E) BEDROOM 107 A 2'-6" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />'' "W112 (E) BEDROOM 107 A 2'-6" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />'' "W113 (E) LIVING ROOM 108 A 3'-0" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />'' "W114 (E) LIVING ROOM 108 A 3'-0" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />'' "W115 (E) LIVING ROOM 108 A 4'-0" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />'' "W116 (E) LIVING ROOM 108 A 4'-0" X 5'-0" V.I.F.PER PLN.VINYL TBD ----'' " <br />1042 (E) BATH 104 B 2'-8" X 6'-8" V.I.F.--TBD TBD TBD TBD -------- <br />1081 (E) LIVING ROOM 108 B 3'-0" X 6'-8" V.I.F.--TBD TBD TBD TBD -------- <br />1031 (E) BEDROOM 103 A 2'-8" X 6'-8" V.I.F.--TBD TBD TBD TBD ------------ <br />1041 (E) BATH 104 A 2'-8" X 6'-8" V.I.F.--TBD TBD TBD TBD ------------ <br />1051 (E) MASTER BATH 105 A 2'-8" X 6'-8" V.I.F.--TBD TBD TBD TBD -------- <br />1061 (E) MASTER BEDROOM 106 A 2'-8" X 6'-8" V.I.F.--TBD TBD TBD TBD -------- <br />1062 (E) MASTER BEDROOM 106 C 5'-0" X 6'-8" V.I.F.--TBD TBD TBD TBD -------- <br />1071 A 2'-8" X 6'-8" V.I.F.--TBD TBD TBD TBD -------- <br />1072 (E) BEDROOM 107 C 5'-0" X 6'-8" V.I.F.--TBD TBD TBD TBD -------- <br />(E) BEDROOM 107 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />0.29 0.20 <br />---- <br />HOLD-2001 S Birch <br />St10/30/2024