Laserfiche WebLink
CAT.HD6135FB <br />135° FIXED & <br />RATE OF RISE <br />Microprocessor controlled -Features <br />Fixed Rate and Rate of Rise temperature <br />sensing - allows unit to alarm prior to <br />reaching the fixed temperature setting <br />of 135° F. <br />LATCHING ALARM <br />INDICATOR <br />Remembers which unit initiated an alarm. <br />SILENCE FEATURE <br />Silences nuisance alarms. <br />TWO LOCKING <br />FEATURES <br />Pins are provided to lock battery drawer <br />and/or alarm to base. Perfect for <br />apartment, dormitory or hotel <br />applications. <br />Description: <br />The BRK Brands, Inc. Model Number HD6135FB is a wire-in, 120V AC 60Hz single <br />and/or multiple station heat alarm designed to supplement smoke alarms in resi- <br />dential and institutional applications including sleeping rooms of hospitals, hotels, <br />motels, dormitories and other multi-family dwellings as defined in standard NFPA <br />101. Models HD6135FB complies with UL539, CSFM, NFPA 72, HUD, FHA and <br />other agencies that model their codes after the above agencies. They meet build- <br />ing codes where AC and AC/DC with Silence heat alarms are required. The alarms <br />are interconnectable with up to 18 devices, of which 12 can be smoke alarms. This <br />heat alarm is not a smoke alarm nor has it been designated a life safety device. <br />BRK Electronics HD6135FB is designed to give reliable early warning of heat from <br />fire. It is recommended for garages, crawl spaces, bathrooms, kitchens, laundry <br />rooms or other applications not suitable for smoke alarm installations. The unit <br />contains a thermistor that senses heat and will alarm when either the temperature <br />reaches 135°F or when a rate of rise of 15°F/minute is sensed by the micropro- <br />cessor. This feature enables a more rapid response to a potential fire. The unit <br />has an 85dB horn, a 9V battery backup power supply, an easy access side-load <br />battery drawer. This alarm features Alarm Latch: Easily identifies initiating alarm <br />even after alarm condition has subsided; Low Battery Silence: Temporarily silence <br />the low battery chirp for up to eight hours; Alarm Silence: Silence alarm for several <br />minutes. Two locking features are provided to prevent battery theft and/or theft of <br />the unit. Connection to AC power is made with a Quick-Connect wiring harness. <br />Installation is quick, easy and cost effective. <br />120V AC, 60Hz Wire-in <br />with 9V Battery Backup <br />HEAT <br />ALARM <br />CAT.HD6135FB <br />ARCHITECTURAL AND ENGINEERING SPEC <br />TECHNICAL SPECS <br />SHIPPING SPECS <br />INSTALLATION OF ALARM <br />The heat alarm shall be a BRK Model HD6135FB and shall provide at a minimum the <br />following features and functions: <br />1. A thermistor and microprocessor capable of sensing and alarming at a 135°F <br />fixed temperature level and a 15°F/min. rate of rise temperature change. <br />2. The unit shall be capable of self restoring. <br />3. Powered by 120V AC, 60Hz and have a monitored 9V battery backup and a solid <br />state piezo horn rated at 85dB at 10 ft. <br />4. A visual green LED power-on indicator to confirm unit is receiving power or is in <br />alarm. <br />5. A full function test button should check all alarm functions by simulating a <br />smoke condition, causing the unit to alarm. <br />6. Silence feature - Temporarily silence unwanted nuisance alarms. <br />7. Two Locking features - tamper resistant locking pins that lock battery drawer <br />and/or alarm to mounting bracket. <br />8. The unit shall be capable of operating between -10°F (-23°C) and 100°F (38°C) <br />and relative humidity between 10% and 90%. <br />9. The unit shall have a gasketless base for easy installation and be capable <br />of keeping alarm secure over a wide rotation range to allow for true alarm <br />alignment. <br />10. The unit shall have a plug in connector and be capable of interconnection of up <br />to 18 alarms, 12 of which can be smoke alarms. <br />11. The unit shall at a minimum meet the requirements of UL539, CSFM, NFPA 72, <br />NFPA 101, ICC. <br />Alarm Dimensions: 5.6”dia. x 2.0”H <br />Weight: 7.3 oz <br />Operating Voltage: 120V AC 60Hz w/ 9V alkaline battery backup <br />Operating Current: 0.05 amps (standby/alarm) <br />Temperature Range: -10°F (-23°C) to 100°F (38°C) <br />Humidity Range: 10% to 95% relative humidity (RH) <br />Audio Alarm: 85dB at 10 feet <br />Test/Silence: Electronically simulates alarm condition, causing the <br />unit to alarm. Press and hold test/silence button. <br />Alarm Reset: Automatic when temperature cools below 130°F <br />Interconnections: Up to 18 units of First Alert or BRK Smoke, CO and Heat <br />Alarms. Maximum of 12 smoke alarms. See user’s manual <br />for details. <br />Heat Sensor: Thermistor <br />Indicator Lights/Sounds: <br /> AC Power: Constant Green LED <br /> DC Power: Intermittent Green LED <br /> Local Alarm: Red LED flashes rapidly, audio alarm <br /> Remote Alarm: Red LED out. <br /> Latching Alarm: Red LED flashes after local alarm <br />Listing: Listed to UL539 Standard <br />Individual Carton Dimensions 5.50”L x 2.50”W x 5.63”H <br /> Weight 0.50 lbs. <br /> Cube 0.05 ft3 <br /> UPC 0 29054 50810 2 <br />Master Carton Dimensions 16.81”L x 10.31”W x 6.25”H <br />Master Pack 12 <br /> Weight 6.3 lbs. <br /> Cube: 0.63 ft3 <br /> I2of5: 100 29054 50810 9 <br />Pallet Information <br /> Cases per Layer 10 <br /> Number of Layers: 7 <br /> Cases per Pallet: 70 <br /> Units per Pallet: 840 <br /> Cube: 54.7 ft3 <br /> Weight: 550 lbs. <br />©2016 BRK Brands, Inc. a subsidiary of Newell Brands <br />(NYSE: NWL) <br />3901 Liberty Street Road <br />Aurora, IL 60504-8122 <br />All rights reserved <br />First Alert is a registered trademark of the First Alert Trust <br />BRK is a registered trademark of BRK Brands, Inc. <br />CM3272brkelectronics.com <br />Installation of this heat alarm must conform to all local electrical codes <br />and Article 760 of the National Electrical Code (NFPA 70) and NFPA <br />72. Interconnected units must meet the following requirements: Total <br />length of wire interconnecting units should be less than 1000 feet, be <br />#18 gauge or larger and be rated at least 300V. It is recommended <br />that all units be on the same fuse or circuit breaker. If local codes <br />do not permit, be sure the neutral wire is common to both phases. <br />THE PARTS OF THIS HEAT ALARM <br />1. Mounting bracket <br />2. Mounting Slots <br />3. Locking Pins <br />4. Hot (Black) AC Wire <br />5. Neutral (White) AC Wire <br />6. Interconnect (Orange) Wire <br />7. Battery Drawer Latch <br />8. Battery Drawer - Install 9V <br />battery here <br />9. Quick-Connect Plug <br />MOUNTING <br />BRACKETTOP VIEW SIDE VIEW <br />5.6” <br />2.0” <br />1 <br />2 <br />3 <br />5 <br />6 <br />4 <br />2 <br />3 <br />9 <br />7 <br />8 <br />1. Heat Alarm <br />2. Ceiling or Wall <br />3. Power Connector <br />4. Wire Nut <br />5. Junction Box <br />6. Neutral Wire (White) <br />7. Interconnect Wire (Orange) <br />8. Hot Wire (Black) <br />A. Unswitched 120VAC 60 Hz source <br />B. To additional units; Maximum = 18 total <br />(Maximum 12 Smoke Alarms) <br />678 <br />43 152A <br />B <br />} <br />} <br />43 15 <br />2209 N Linwood <br />Ave8/22/2024