testing for verification of potential deep-seated settlement are not considered necessary and <br />not performed for this project. <br />The lowest bearing capacity of 1,500 psf. Is recommended to be used for the proposed new <br />structures. Therefore, direct shear testing is not considered necessary and not performed for <br />this project. <br />For conservative purposes, Type V cement with concrete strength of 4,500 psi is recommended <br />to be used for concrete in contact with the on-site soils. Therefore, sulfate content testing is <br />not considered necessary and not performed for this proposed project. <br />Problems of the underlying soils, if any have been previously properly treated and judged to be <br />adequate for structural support, and approved by the City prior to construction of the existing <br />house. In addition, for conservative purposes, remedial removal/ over-excavation and <br />recompaction of the existing soils underlying the proposed new structure is recommended for <br />this project. Therefore, conventional laboratory tests such as moisture content & in-situ <br />density, grain-size analysis, etc. are not considered necessary and not performed for this <br />project. <br />Groundwater <br /> Free standing groundwater was not encountered in our 5 ft deep test hole. <br />Free standing ground water was not reported to be an issue at the site and in the vicinity deep <br />footing/excavation are not proposed for the site; therefore adverse effects due to groundwater <br />are not anticipated for the proposed development. Historic groundwater levels have been <br />recorded approximately 20’ to 25’ below ground surface. <br />Note: it is not anticipated; however, if wet soils are encountered, removal of the wet soil and <br />replacement with drier soils/cement slurry can be performed. In addition, if need crushed rock <br />and or geogrid for bridging, etc. can also be used. This will be determine by the geotechnical <br />consultant based on the exposed conditions during the excavations the site <br />Seismicity <br />The subject site is located in Southern California, which is a major earthquake-pr zone. <br />Therefore, the owner(s) of this property should be aware of the seismic r associated with being <br />located in this zone. <br />The Soil Site Class D Default can be used for the soils underlying the subject site. <br />The Seismic Design Category D can be used for the site. <br />The following seismic parameters obtained from the computer <br />program seismicmaps.org prepared by SEAOC [Structural Engineers Association California] in <br />1927 & 1929 S <br />Hickory St2/12/2025