Laserfiche WebLink
REF <br />SD <br />SD SD <br />CM <br />ATTIC VENT CALCULATION <br />AREA VENTILATED <br />1000.5 SF <br />RATE REQ. VENTS: <br />150 960.5 SQ.IN <br />TYPE <br />O'HAGING VENT <br />QTY.AREA PER UNIT <br />9 120 SQ.IN <br />TOTAL AREA PROVIDED <br />1080 SQ.IN <br />14"x18" GABLE END VENT 0 110 SQ.IN 0 SQ.IN <br />24"x12" DORMER VENT 0 100 SQ.IN 0 SQ.IN <br />2.5" SCREENED 3-HOLE VENTS 0 15 SQ.IN 0 SQ.IN <br />5.5"x14.5" SOFFIT VENTS 0 65 SQ.IN 0 SQ.IN <br />TOTAL VENTILATION PROVIDED 1080 SQ.IN <br />D5D5 <br />D4 D4 <br />D4 <br />D4 <br />D6 <br />D2 <br />D1 <br />W2 W2 <br />W3 <br />W1 <br />D3 <br />W4W4 <br />W4 <br />D1 <br />WH <br />AC <br />4' <br /> <br />- <br /> <br />0 <br />" <br />3' - 0" <br />B-B <br />A5 <br />A-A <br />A5 <br />01 <br />06 <br />02 <br />12 <br />10 09 05 <br />15 <br />13 <br />06 <br />02 <br />12 <br />14 <br />03 <br />11 11 <br />04 <br />07 <br />08 <br />1' <br /> <br />- <br /> <br />0 <br />" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />2' - 0"5' - 0"2' - 11"2' - 11"5' - 0"2' - 0" <br />1' <br /> <br />- <br /> <br />3 <br />" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />2 <br />" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />5' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />3 <br />" <br />2' <br /> <br />- <br /> <br />0 <br />" <br />8' <br /> <br />- <br /> <br />0 <br />" <br />2' <br /> <br />- <br /> <br />5 <br />" <br />4' <br /> <br />- <br /> <br />9 <br />" <br />3' <br /> <br />- <br /> <br />0 <br />" <br />4' <br /> <br />- <br /> <br />9 <br />" <br />2' - 6" <br />8' - 0"1' - 6" <br />9' - 8"9' - 2" <br />2' - 6" <br />2' <br /> <br />- <br /> <br />5 <br />" <br />2' <br /> <br />- <br /> <br />5 <br />" <br />31 <br />' <br /> <br />- <br /> <br />1 <br />" <br />CH: 9'-0"CH: 9'-0"CH: 9'-0"CH: 9'-0" <br />1-HOUR FIRE RESISTIVE <br />CONSTRUCTION BETWEEN GARAGE <br />AND DWELLING CONTINOUS FROM <br />FOUNDATION TO ROOF SHEATING <br />31 <br />' <br /> <br />- <br /> <br />1 <br />" <br />43 <br />' <br /> <br />- <br /> <br />6 <br />" <br />43 <br />' <br /> <br />- <br /> <br />6 <br />" <br />36"X80" (N) SOLID CORE - <br />SELF CLOSING-1HR <br />11' - 7"11' - 7" <br />12 <br />' <br /> <br />- <br /> <br />0 <br />" <br />20' - 0" <br />TEMP <br />TEMP <br />EGRESS EGRESS <br />TEMP <br />8 <br />AD.2 <br />4" / 12" <br />4" / 12" <br />4" <br /> <br />/ <br /> <br />1 <br />2 <br />" <br />1' - 0" <br />1' - 0" <br />NOTE: TO MATCH EXISTING <br />PRIMARY HOUSE ROOFING <br />1' <br /> <br />- <br /> <br />0 <br />" <br />5 <br />A3 <br />LEGEND <br />O'HAGING VENT <br />BUILDING LINE <br />SLOPE <br />4" / 12" <br />SHEET NO.: <br />SHEET <br />TITLE: <br />AS SHOWN <br />SCALE: <br />DATE: <br />DR <br />A <br />W <br />I <br />N <br />G <br />S <br /> <br />P <br />R <br />O <br />V <br />I <br />D <br />E <br />D <br /> <br />B <br />Y <br />: <br />DE <br />L <br />T <br />A <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br /> <br />C <br />O <br />. <br />86 <br />7 <br />1 <br /> <br />G <br />A <br />R <br />D <br />E <br />N <br /> <br />G <br />R <br />O <br />V <br />E <br /> <br />BL <br />V <br />D <br />. <br />, <br /> <br />G <br />A <br />R <br />D <br />E <br />N <br /> <br />G <br />R <br />O <br />V <br />E <br />71 <br />4 <br />- <br />9 <br />8 <br />7 <br />- <br />0 <br />7 <br />8 <br />7 <br />A3 <br />PROPOSED <br />ADU FLOOR & <br />ROOF PLAN <br />04/10/2024 <br />19 <br />2 <br />9 <br /> <br />& <br /> <br />1 <br />9 <br />2 <br />7 <br /> <br />S <br />HI <br />C <br />K <br />O <br />R <br />Y <br /> <br />S <br />T <br />. <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />92 <br />7 <br />0 <br />7 <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br />AD <br />U <br />DOOR SCHEDULE <br />TAG DOOR TYPE OPERATION WIDTH HEIGHT QTY <br />D1 SOLID SWINGING 3' - 0"6' - 8"2 <br />D2 GARAGE DOOR ROLL-UP 8' - 0"7' - 0"1 <br />D3 SOLID SELF CLOSING 1 HR FIRE RATED 3' - 0"6' - 8"1 <br />D4 <varies>SWINGING 2' - 6"6' - 8"5 <br />D5 CLOSET SLIDING 5' - 0"6' - 8"2 <br />D6 CLOSET BIFOLD 4' - 0"6' - 8"1 <br />N <br />1. <br />2. <br />3. <br />THE ATTIC ACCESS SHALL BE A MINIMUM OF 22" X 30". A THIRTY-INCH MINIMUM <br />CLEAR HEAD ROOM SHALL BEPROVIDED ABOVE THE ATTIC ACCESS. ATTIC <br />ACCESS SHALL BE LOCATED AT A READILY ACCESSIBLE LOCATION <br />MECHANICAL VENTILATION IS NOT LESS THAN 6 AIR CHANGES PER HOUR TYPE. <br />THE POINT OF DISCHARGE OFEXHAUST AIR SHALL BE AT LEAST 3 FEET FROM <br />ANY OPENING INTO THE BUILDING. THE EXHAUST VENT SHALL BEEQUIPPED WITH <br />BACK-DRAFT DAMPER TO COMPLY WITH ENERGY REGULATIONS. <br />PROVIDE OUTDOOR COMBUSTION AIR OPENINGS FOR THE MECHANICAL CLOSET <br />WITH THE 2 PERMANENT OPENINGSMETHOD PER CMC SECTION 701.4.1. ONE <br />OPENING SHALL COMMENCE WITHIN12 INCHES OF THE TOP AND THE <br />OTHERCOMMENCING WITHIN 12 INCHES OF THE BOTTOM OF THE ENCLOSURE <br />VENTILATION NOTES: <br />A. <br />B. <br />C. <br />PROVIDE NO LESS THAN 30% UPPER VENTS. <br />BE INSTALLED ON VERTICAL ATTIC SURFACES AND GABLE ENDS. <br />WHEN INSTALLED IN ENCLOSED RAFTER SPACES A MINIMUM AIR SPACE OF 1" <br />MUST BE PROVIDED AND VENTILATIONBE PROVIDED AT UPPER AND LOWER END <br />OF EVERY RAFTER BARRIER. <br />RADIANT BARRIER INSTALLATION SHALL <br />COMPLY WITH THE FOLLOWING: <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />SAFETY OR TEMPERED GLAZING REQUIRED IN THE FOLLOWING LOCATIONS: <br />GLAZING IN ENCLOSURES FOR OR WALLFACING HOT TUBS, WHIRLPOOLS, BATHTUBS <br />AND SHOWERS WHERE THE BOTTOM EXPOSED EDGE IS LESS THAN 60INCHES <br />MEASURED VERTICALLY AVOVE A STANDING OR WALKING SURFACE (CRC R308.4) <br />CEMENT, FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT GYPSUM OR <br />FIBER-REINFORCED GYPSUMBACKERS SHALL USED AS A BASE FOR WALL TILE IN <br />TUB AND SHOWER AREAS AND WALL AND CEILING PANELS INSHOWER AREAS. <br />(R702.4.2 CRC) <br />SHOWERS AND TUB-SHOWER COMBINATION VALVES SHALL BE EQUIPPED WITH A <br />MEANS TO LIMIT THE MAXIMUMSETTING OF THE VALVE TO 120 DEGREES F (CPC <br />408.3) <br />NEW ADU SHALL MATCH EXISTING RESIDENCE ARCHITECTURALSTYLE, BUILDING <br />MATERIALS, WINDOW STYLE, WINDOW FRAMES,ROOFING STYLE, ALL MATERIALS AND <br />DESIGN. <br />VENT OPENINGS SHALL BE PROVIDED WITH CORROSION-RESISTANT WIRE MESH WITH <br />1/16" MINIMUM TO 1/4" MAXIMUMOPENINGS. A MINIMUM OF A 1-INCH AIRSPACE MUST <br />BE MAINTAINED BETWEEN THE INSULATION AND THE ROOF SHEATHING ATTHE <br />LOCATIONS OF THE VENTS. [CRC R806] <br />BATHROOM EXHAUST FANS SHALL BE ENERGY STAR COMPLIANT, DUCTED TO <br />TERMINATE OUTSIDE THEBUILDING, AND CONTROLLED BY A HUMIDISTAT CAPABLE <br />OF BEING ADJUSTED BETWEEN THE RELATIVE HUMIDITYRANGE OF 50 TO 80 <br />PERCENT. [CGBC 4.506] <br />WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQUAL TO 72 <br />INCHES ABOVE DRAIN AT SHOWERSOR TUB WITH SHOWERS. MATERIALS OTHER <br />THAN STRUCTURAL ELEMENTS ARE TO BE MOISTURE RESISTANT. [CRCR307.2] <br />NOTES:SCALE: 1/4" = 1'-0"1 PROPOSED FLOOR PLAN <br />SCALE: 1/4" = 1'-0"2 PROPOSED ROOF PLAN N <br />KEYNOTESKEYNOTES <br />01 DRYER; A) PROVIDE 4" DIA. SMOOTH METAL DUCT FOR DRYER EXHAUST EXTENDING TO <br />OUTSIDE W/ BACK DRAFT DAMPER (36" MIN. AWAY FROM OPENING). ;B) MAX. VENT DUCT <br />LENGTH OF 14'. ;C) DOOR AT LAUNDRY ROOM MUST BE LOUVERED TO ALLOW DRYERS TO <br />HAVE SUFFICIENT MAKE-UP AIR.;D) THE SPECIFICATION WILL BE ON A DEFERRED SUBMITTAL. <br />:E) THE DRYER MOISTURE EXHAUST DUCT TO BE METAL OR MOISTURE RATED PVC WITH A <br />SMOOTH INTERIOR SURFACE W/O SCREWS. <br />02 MINIMUM SHOWER SIZE 1,024 SQ. IN. WITH NO LESS THAN 30" IN ANY DIRECTION (MUST <br />ENCOMPASS A 30" CIRCLE). SHOWER DOORMIN. 22" WIDE, TEMPERED. WATER CLOSET MUST BE <br />CENTERED IN A 30" CLEAR SPACE AND MUST HAVE A 24" CLEAR IN FRONT. FLOORS AND <br />WALL SHALL BE FINISHED WITH A NONABSORBENT SURFACE, SUCH WALL SURFAVES SHALL <br />EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE THE FLOOR. <br />03 22" x 30" ATTIC ACCESS, WITH 30-INCHES MINIMUM CLEAR UNOBSTRUCTED HEADROOM ABOVE <br />THE CEILING. (CRC R807). <br />04 EXTERIOR LANDING AT THE EXTERIOR DOOR SHALL BE A MAXIMUM OF 7-3/4" BELOW THE TOP <br />OF THE THRESHOLD, PROVIDED THE DOOR DOES NOT SWING OVER THE LANDING OR FLOOR. <br />05 NO DISHWASHING MACHINE SHALL BE DIRECTLY CONNECTED TO A DRAINAGE SYSTEM OR <br />FOOD WASTE DISPOSER WITHOUT THE USE OF AN APPROVED DISHWASHER AIR GAP FITTING ON <br />THE DISCHARGE SIDE OF THE DISHWASHING MACHINE. LISTED AIR GAPS SHALL BE INSTALLED <br />WITH THE FLOOD-LEVEL (Fl0 MARKING AT/ ABOVE THE FLOOD LEVEL OF THE SINK OR DRAIN <br />BOARD, WHICHEVER IS HIGHER. CPC SEC.807.3 <br />06 CONTINUOUS REINFORCING BACKING FOR FUTURE GRAB BARS. CRC SECTION R327.1.1 ;A) <br />REINFORCEMENT SHALL BE A MINIMUM OF 2X8 SOLID LUMBER AND SHALL BE LOCATED <br />BETWEEN 32 INCHES AND 39-1/4 INCHES ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL <br />FRAMING. ;B) WATER CLOSET REINFORCEMENT SHALL BE INSTALLED ON BOTH SIDE WALLS OF <br />THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. EXEMPTION #1: WHERE THE WATER <br />CLOSET IS NOT PLACED ADJACENT TO A SIDE WALL CAPABLE OF ACCOMMODATING A GRAB <br />BAR, THE BATHROOM SHALL HAVE PROVISIONS FOR INSTALLATION OF FLOOR -MOUNTED <br />FOLDAWAY OR SIMILAR ALTERNATE GRAB BAR REINFORCEMENTS APPROVED BY THE <br />ENFORCING AGENCY.; C) INFORMATION AND/ OR DRAWINGS IDENTIFYING THE LOCATION OF <br />GRAB BAR REINFORCEMENT SHALL BE PLACED IN THE OPERATION AND MAINTENANCE <br />MANUAL IN ACCORDANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS CODE. <br />CHAPTER 4. DIVISION 4.4 CRC SECTION R3271.1.1.; D) SHOWER REINFORCEMENT SHALL BE <br />CONTINUOUS WHERE FRAMING IS PROVIDED.; D) REINFORCEMENT SHALL NOT BE REQUIRED IN <br />WALL FRAMING FOR PRE-FABRICATED SHOWER ENCLOSURES AND BATHTUB WALL PANELS WITH <br />INTEGRAL FACTORY-INSTALLED GRAB BARS OR WHEN FACTORY-INSTALLED REINFORCEMENT <br />FOR GRAB BARS IS PROVIDED. EXCEPTION #2. ;E) SHOWER ENCLOSURES THAT DO NOT <br />PERMIT INSTALLATION OF REINFORCEMENT AND/ OR GRAB BARS SHALL BE PERMITTED, <br />PROVIDED REINFORCEMENTS FOR INSTALLATION OF FLOOR-MOUNTED GRAB BARS OR AN <br />ALTERNATE METHOD IS APPROVED BY THE ENFORCING AGENCY. EXCEPTION #3. <br />07 AIRCONDITIONER OUTDOOR UNIT <br />08 50-GAL ELECTRIC HEAT PUMP WATER HEATER WITH PRESSURE WATER RELIEF VALVE WITH <br />DRAIN OUTSIDE WATER HEATER. CPC 504.6. SE DETAIL 1 2/AD.1.ELECTRIC WATER HEATER, <br />SPECIFICATIONS PER ENERGY DOCUMENTATION <br />09 LOCAL EXHAUST VENTILATION HOOD, MIN. 100 CFM <br />10 REFRIGERATOR SPACE W/ COLD WATER STUB-OUT FOR ICEMAKER (VERIFY SIZE W/ MNFR) <br />11 30" x 60" TUB/SHOWER W/ CURTAIN ROD, IMPERVIOUS SURROUND ON 3 WALLS +7'-0" (MIN. 72"). <br />12 LAVATORY SINK [CPC TABLE 422.1] [PENETRATIONS IN WALL LINE (I) SHALL COMPLY WITH CRC <br />R302.4] <br />13 KITCHEN CABINET LAYOUT BY OWNER/CONTRACTOR <br />14 ELECTRIC PANEL <br />15 KITCHEN SINK W/ GARBAGE DISPOSAL (SEE CALGREEN SHEET FOR MAX FLOW RATE) <br />WINDOW SCHEDULE <br />TAG QTY TYPE/OPERATION MATERIAL WIDTH HEIGHT <br />HEAD <br />HEIGHT <br />W1 1 SLIDING VINYL FRAME W/ LOW E-DOUBLE PANE GLASS <br />(TEMPERED) <br />5' - 0"4' - 0"6' - 8" <br />W2 2 SLIDING VINYL FRAME W/ LOW E-DOUBLE PANE GLASS <br />(TEMPERED) <br />3' - 0"1' - 0"6' - 8" <br />W3 1 SLIDING VINYL FRAME W/ LOW E-DOUBLE PANE GLASS3' - 0"3' - 0"6' - 8" <br />W4 3 SLIDING VINYL FRAME W/ LOW E-DOUBLE PANE GLASS5' - 0"4' - 0"6' - 8" <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br /> <br />T <br />A <br />B <br />L <br />E <br />NU <br />M <br />B <br />E <br />R <br />DA <br />T <br />E <br />RE <br />V <br />I <br />S <br />E <br />D <br /> <br />B <br />Y <br />DE <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br />1927 & 1929 S <br />Hickory St2/12/2025