My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1927 & 1929 S Hickory St - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Hickory St
>
1927 S Hickory St
>
1927 & 1929 S Hickory St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:07 PM
Creation date
6/6/2025 1:18:33 PM
Metadata
Fields
Template:
Plan
Permit Number
102121150
Full Address
1927 S Hickory St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
sheet no.:A2 <br />Project:1929 Hickory <br />ROOF: roof DL= 10 psf <br />partitions=5 psf <br />W roof=15 psf <br />2ND FLOOR:floor DL=0 psf <br />partitions=0 psf <br />w floor=0 psf <br />W Total=15 psf <br />Latitude;33.72267 <br />longitude:-117.8602 <br />Ss 1.278 <br />S1 0.457 <br />Site Class:D <br />Risk Category:II ASCE 7 Table 1.5-1 <br />Ie=1 ASCE 7 Table 1.5-2 <br />Fa=1.2 <br />SMS 1.534 <br />SDS 1.022 <br />D ASCE 7 Table 11.6-1 <br />rho=1.3 <br />Plywood Shear Walls <br />6.5 ASCE 7 Table 12.2-1 <br />Base Shear Coefficient SDS*I/R=Cs=0.157 (Strength) <br />0.7SDS*I/R Cs=0.110 (Service) <br />V=CsW=V=2.77 psf <br />Seismic Calcs <br />15 lb/sf Lb <br />1012 sf <br />10,251 lb <br />134 ft <br />4.5 ft <br />17 lb/sf <br />25,431 lb <br />2.77 lb/sf <br />Wind Load Calcs <br />9.6 lb/sf <br />L=44 7,603 lb <br />W=23 3,974 lb <br />Wind Load= Wind Pressure x Wall Height x L x 2= <br />Wind Load= Wind Pressure x Wall Height x W x 2= <br />Celing Heigh / 2 = <br />Wall Wight = <br />Wtotal= Wroof + Wwall = <br />V = Cs x Wtotal/Bld Area = <br />Wind Pressure (16 lb/sf) x 0.6 <br />Wroof = Bld. Area x Roof SF weight= <br />Bld. Area= <br />15,180 <br />Wwall = Bld. Circumference x (ceiling heigh/2)x wall wight per LF <br />Bld. Circumference = <br />Importance Factor: <br />Site Coefficient: <br />EQUIVALENT LATERAL FORCE PROCEDURE (ASCE 7 Section 12.8): <br />Site Spectural Accel Value <br />Design Response: <br />Seismic Design Category: <br />Redundancy Factor <br />Seismic Force Resisting System <br />Response Modification Factor <br />LATERAL ANALYSIS (ASCE 7-16) <br />STORY WEIGHTS: <br />SEISMIC: <br />Maximum Short Period Response: <br />maximum 1 sec. Period Response: <br />1927 & 1929 S <br />Hickory St2/12/2025