My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1927 & 1929 S Hickory St - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Hickory St
>
1927 S Hickory St
>
1927 & 1929 S Hickory St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:07 PM
Creation date
6/6/2025 1:18:33 PM
Metadata
Fields
Template:
Plan
Permit Number
102121150
Full Address
1927 S Hickory St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)243 @ 2 1/2"2231 (3.50")Passed (11%)--1.0 D + 1.0 L (All Spans) <br />Shear (lbs)218 @ 9"990 Passed (22%)1.00 1.0 D + 1.0 L (All Spans) <br />Moment (Ft-lbs)836 @ 7' 3 1/2"819 Passed (102%)1.00 1.0 D + 1.0 L (All Spans) <br />Live Load Defl. (in)0.513 @ 7' 3 1/2"0.708 Passed (L/332)--1.0 D + 1.0 L (All Spans) <br />Total Load Defl. (in)0.854 @ 7' 3 1/2"0.944 Passed (L/199)--1.0 D + 1.0 L (All Spans) <br />Member Length : 14' 7" <br />System : Ceiling <br />Member Type : Attic Joist <br />Building Use : Residential <br />Building Code : IBC 2018 <br />Design Methodology : ASD <br />Member Pitch : 0/12 <br />•Deflection criteria: LL (L/240) and TL (L/180). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Floor/Ceiling <br />Live Factored Accessories <br />1 - Stud wall - SPF 3.50"3.50"1.50"97 146 243 Blocking <br />2 - Stud wall - SPF 3.50"3.50"1.50"97 146 243 Blocking <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)6" o/c <br />Bottom Edge (Lu)14' 7" o/c <br />• Only vertical loads are available for Attic Joist member types. No tension loading will be considered in the design for these members. <br />Dead <br />Floor/Ceiling <br />Live <br />Vertical Load Location (Side)Spacing (0.90)(1.00)Comments <br />1 - Uniform (PSF)0 to 14' 7"16"10.0 15.0 Default Load <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to <br />www.weyerhaeuser.com/woodproducts/document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal. <br />MEMBER REPORT PASSED <br />Level, Ceiling: Attic Joist <br />1 piece(s) 2 x 6 DF No.1 @ 16" OC <br />ForteWEB Software Operator Job Notes 4/8/2024 2:15:23 PM UTC <br />Ehab Elias <br />Structural Ventures <br />(760) 484-6343 <br />eliasehab@gmail.com <br />ForteWEB v3.7, Engine: V8.4.0.40, Data: V8.1.5.0 <br />File Name: Hickory <br />Page 1 / 1 <br />1927 & 1929 S <br />Hickory St2/12/2025
The URL can be used to link to this page
Your browser does not support the video tag.