My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1927 & 1929 S Hickory St - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Hickory St
>
1927 S Hickory St
>
1927 & 1929 S Hickory St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:07 PM
Creation date
6/6/2025 1:18:33 PM
Metadata
Fields
Template:
Plan
Permit Number
102121150
Full Address
1927 S Hickory St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
104
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Design Results Actual @ Location Allowed Result LDF Load: Combination (Pattern) <br />Member Reaction (lbs)4121 @ 2"12031 (3.50")Passed (34%)--1.0 D + 1.0 Lr (All Spans) <br />Shear (lbs)3382 @ 1' 1"7402 Passed (46%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Moment (Ft-lbs)11773 @ 6' 1/2"11634 Passed (101%)1.25 1.0 D + 1.0 Lr (All Spans) <br />Live Load Defl. (in)0.263 @ 6' 1/2"0.587 Passed (L/537)--1.0 D + 1.0 Lr (All Spans) <br />Total Load Defl. (in)0.465 @ 6' 1/2"0.783 Passed (L/303)--1.0 D + 1.0 Lr (All Spans) <br />Member Length : 12' 1" <br />System : Roof <br />Member Type : Flush Beam <br />Building Use : Residential <br />Building Code : IBC 2021 <br />Design Methodology : ASD <br />Member Pitch : 0/12 <br />•Deflection criteria: LL (L/240) and TL (L/180). <br />•Allowed moment does not reflect the adjustment for the beam stability factor. <br />•Lumber grading provisions must be extended over the length of the member per NDS 4.2.5.5. <br />•Applicable calculations are based on NDS. <br />• Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br />Bearing Length Loads to Supports (lbs) <br />Supports Total Available Required Dead Roof Live Factored Accessories <br />1 - Stud wall - DF 3.50"3.50"1.50"1795 2326 4121 Blocking <br />2 - Column - DF 3.50"3.50"1.50"1795 2326 4121 Blocking <br />•Maximum allowable bracing intervals based on applied load. <br />Lateral Bracing Bracing Intervals Comments <br />Top Edge (Lu)6" o/c <br />Bottom Edge (Lu)12' 1" o/c <br />• Side loads are assumed to not induce cross-grain tension. <br />Dead Roof Live <br />Vertical Loads Location (Side)Tributary <br />Width <br />(0.90)(1.25)Comments <br />0 - Self Weight (PLF)0 to 12' 1"N/A 13.2 -- <br />1 - Uniform (PSF)0 to 12' 1" (Front)11'15.8 20.0 Roof <br />2 - Uniform (PSF)0 to 12' 1" (Front)11'10.0 15.0 Ceiling <br />Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values. Weyerhaeuser expressly disclaims any other warranties <br />related to the software. Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction. The designer of record, builder or framer is <br />responsible to assure that this calculation is compatible with the overall project. Accessories (Rim Board, Blocking Panels and Squash Blocks) are not designed by this software. Products manufactured at <br />Weyerhaeuser facilities are third-party certified to sustainable forestry standards. Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br />and/or tested in accordance with applicable ASTM standards. For current code evaluation reports, Weyerhaeuser product literature and installation details refer to www.weyerhaeuser.com/woodproducts/ <br />document-library. <br />The product application, input design loads, dimensions and support information have been provided by ForteWEB Software Operator <br />Weyerhaeuser Notes <br />Drawing is Conceptual. All locations are measured from the outside face of left support (or left cantilever end). All dimensions are horizontal (typ.). <br />MEMBER REPORT PASSED <br />Roof, Roof: Living Room Flush Beam <br />1 piece(s) 6 x 10 DF No.1 <br />ForteWEB Software Operator Job Notes 11/15/2024 4:05:19 AM UTC <br />ForteWEB v3.8, Engine: V8.4.1.24, Data: V8.1.6.3 <br />File Name: Hickory <br />Page 1 / 1 <br />1927 & 1929 S <br />Hickory St2/12/2025
The URL can be used to link to this page
Your browser does not support the video tag.