Laserfiche WebLink
A.V. Schwan & Associates JOB TITLE F&D Santa Ana CPU Canopy <br />6000 E Thomas Rd <br />Scottsdale, AZ 85251 JOB NO.7202 SHEET NO. <br />602-265-4331 CALCULATED BY ATB DATE <br />CHECKED BY MK DATE <br />www.struware.com <br />Code Search <br /> Code: <br /> Occupancy: <br />Occupancy Group =S <br /> Risk Category & Importance Factors: <br />Risk Category = II <br />Wind factor = 1.00 <br />Snow factor = 1.00 <br />Seismic factor = 1.00 <br /> Type of Construction: <br />Fire Rating: <br />Roof = 0.0 hr <br />Floor = 0.0 hr <br /> Building Geometry: <br />Roof angle (θ) 0.25 / 12 1.2 deg <br />Building length 26.7 ft <br />Least width 22.0 ft <br />Mean Roof Ht (h) 18.0 ft <br />Parapet ht above grd 0.0 ft <br />Minimum parapet ht 0.0 ft <br /> Live Loads: <br />Roof 0 to 200 sf: 20 psf <br />200 to 600 sf: 24 - 0.02Area, but not less than 12 psf <br />over 600 sf: 12 psf <br />Floor: <br />Typical Floor N/A <br />Partitions N/A <br />California Building Code 2022 <br />Storage <br />3 of 42 <br />1801 E Dyer Rd <br />3/11/2025