TYPICAL ABBREVIATIONS
<br />DESCRIPTION
<br />ABV.ABOVE
<br />A.C.T.ACOUSTICAL CEILING TILE
<br />A.D.A.AMERICANS WITH DISABILITIES
<br />ACT
<br />ADD'L ADDITIONAL
<br />A.F.F.ABOVE FINISH FLOOR
<br />A.S.T.M.AMERICAN SOCIETY FOR TESTING
<br />AND MATERIALS
<br />BD.BOARD
<br />BM.BEAM
<br />B.O.BOTTOM OF
<br />C.J.CONTROL JOINT
<br />C.L.CENTERLINE
<br />CLG.CEILING
<br />CLR.CLEAR
<br />C.M.U.CONCRETE MASONRY UNIT
<br />C.O.CLEANOUT
<br />COL.COLUMN
<br />CONC.CONCRETE
<br />C.W.COLD WATER
<br />DEMO DEMOLISH OR DEMOLITION
<br />DIA.DIAMETER
<br />DIM.DIMENSION
<br />DS.DOWNSPOUT
<br />DN.DOWN
<br />DWG.DRAWING
<br />EA.EACH
<br />E.A.EXHAUST AIR
<br />E.I.F.S.EXTERIOR FINISH AND INSULATION
<br />SYSTEM
<br />E.J.EXPANSION JOINT
<br />ELEV.ELEVATION
<br />EQ.EQUAL
<br />EXT.EXTERIOR
<br />F.D.FLOOR DRAIN OR FIRE DAMPER OR
<br />FIRE DEPARTMENT
<br />F.E.FIRE EXTINGUISHER
<br />F.F.FINISH FLOOR
<br />FIN.FINISH
<br />FIXT.FIXTURE
<br />FLR.FLOOR
<br />F.O.FINISH OPENING
<br />F.R.T.FIRE RETARDANT TREATED
<br />FT.FEET
<br />GA.GAUGE
<br />G.C.GENERAL CONTRACTOR
<br />GYP.GYPSUM
<br />HB.HOSE BIB
<br />HDW.HARDWARE
<br />H.M.HOLLOW METAL
<br />HT.HEIGHT
<br />HTR.HEATER
<br />H.V.A.C.HEATING, VENTILATION AND AIR
<br />CONDITIONING
<br />H.W.HOT WATER
<br />I.B.C.INTERNATIONAL BUILDING CODE
<br />I.D.INSIDE DIAMETER
<br />I.E.C.C.INTERNATIONAL ENERGY
<br />CONSERVATION CODE
<br />I.F.C.INTERNATIONAL FIRE CODE
<br />I.M.C.INTERNATIONAL MECHANICAL
<br />CODE
<br />IN.INCH
<br />INFO INFORMATION
<br />INSUL.INSULATION
<br />INT.INTERIOR
<br />I.P.C.INTERNATIONAL PLUMBING CODE
<br />kV KILOVOLT
<br />DESCRIPTION
<br />kVA KILOVOLT-AMPS
<br />kW KILOWATT
<br />kWH KILOWATT-HOUR
<br />LL.LANDLORD
<br />MAX.MAXIMUM
<br />M.D.F.MEDIUM DENSITY FIBERBOARD
<br />MIN.MINIMUM
<br />M.O.MASONRY OPENING
<br />MTL.METAL
<br />N/A NOT APPLICABLE
<br />NEC.NATIONAL ELECTRICAL CODE
<br />NFPA.NATIONAL FIRE PROTECTION
<br />ASSOCIATION
<br />N.I.C.NOT IN CONTRACT
<br />NOM.NOMINAL
<br />N.T.S.NOT TO SCALE
<br />O.C.ON CENTER
<br />O.D.OUTSIDE DIAMETER
<br />OPP.OPPOSITE
<br />PLBG.PLUMBING
<br />PLY.PLYWOOD
<br />PNL.PANEL
<br />PNT.PAINT
<br />PR PAIR
<br />P.S.I.POUNDS PER SQUARE INCH
<br />P.S.F.POUNDS PER SQUARE FOOT
<br />PT.POINT
<br />P.V.C.POLY VINYL CHLORIDE
<br />r.RADIUS
<br />R.A.RETURN AIR
<br />R.C.P.REFLECTED CEILING PLAN
<br />RD ROUND
<br />R.O.ROUGH OPENING
<br />REINF.REINFORCED OR REINFORCING
<br />REQ'D REQUIRED
<br />REV.REVISION
<br />RGH.ROUGH
<br />R.T.U.ROOF TOP UNIT
<br />R.W.L.RAIN WATER LEADER
<br />S.A.SUPPLY AIR
<br />S.F.SQUARE FEET
<br />SIM.SIMILAR
<br />SPEC.SPECIFIED OR SPECIFICATION
<br />S.Q.SQUARE
<br />S.S.STAINLESS STEEL
<br />STC.SOUND TRANSMISSION
<br />COEFFICIENT
<br />STD.STANDARD
<br />STL.STEEL
<br />STRUCT.STRUCTURE
<br />SUSP.SUSPENDED
<br />T&G TONGUE AND GROOVE
<br />TA TO ABOVE
<br />T.B.D.TO BE DETERMINED
<br />TEMP.TEMPORARY
<br />T.O.TOP OF
<br />TPO.THERMOPLASTIC POLYOLEFIN
<br />TYP.TYPICAL
<br />U.L.UNDERWRITER'S LABORATORY
<br />U.N.O.UNLESS NOTED OTHERWISE
<br />U/S UNDERSIDE
<br />V.I.F.VERIFY IN FIELD
<br />V.C.T.VINYL COMPOSITION TILE
<br />W/WITH
<br />W/O WITHOUT
<br />WD.WOOD
<br />W.H.WATER HEATER
<br />W.P.WEATHER PROOF
<br />ACCESSIBILITY GUIDELINES
<br />1.AN UNOBSTRUCTED TURNING SPACE OF 60" IN DIAMETER SHALL BE
<br />PROVIDED WITHIN AN ACCESSIBLE TOILET ROOM.
<br />2.A DOOR, IF PROVIDED, SHALL NOT ENCROACH INTO THE REQUIRED
<br />CLEAR FLOOR SPACE IN FRONT OF THE WATER CLOSET.
<br />3.THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF THE
<br />GRAB BARS SHALL BE 1-1/4" TO 1-1/2" AND THE SPACE BETWEEN THE
<br />WALL AND THE GRAB BAR SHALL BE 1-1/2".
<br />4.CONTROLS AND SWITCHES ON WALLS ARE TO BE PLACED A
<br />MAXIMUM OF 48" ABOVE THE FINISH FLOOR. ELECTRICAL
<br />RECEPTACLES ON WALLS SHALL BE PLACED NO LESS THAN 15"
<br />ABOVE THE FINISH FLOOR. DIMENSIONS ARE TO THE HIGHEST
<br />OPERABLE PART OF CONTROLS AND THE LOWEST OPERABLE PART
<br />OF CONTROLS AND THE LOWEST OPERABLE PART OF
<br />RECEPTACLES.
<br />5.ALL CLEARANCES, MOUNTING HEIGHTS, PATHS OF TRAVEL ETC.
<br />SHALL BE PER CHAPTER 11B OF THE 2022 CALIFORNIA BUILDING
<br />CODE.
<br />6.IN BREAK ROOM, SINK SHALL BE MOUNTED WITH THE HIGHER OF
<br />THE RIM OR COUNTER SURFACE 34" MAX. ABOVE FINISH FLOOR AND
<br />WITH AN 18" MIN. TO THE CENTER FROM ANY ADJACENT WALL.
<br />PROVIDE A 30" X 48" CLEAR FLOOR SPACE PER CHAPTER 11B OF THE
<br />2022 CALIFORNIA BUILDING CODE AND KNEE AND TOE SPACE PER
<br />CHAPTER 11B-306 ALLOWING FORWARD APPROACH. BREAK ROOM
<br />FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND NOT
<br />REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST
<br />PER CHAPTER 11B-309 . OPERABLE FORCE SHALL NOT EXCEED 5
<br />POUNDS. WATER SUPPLY AND DRAIN PIPES SHALL BE INSULATED OR
<br />OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE
<br />SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER SINKS PER
<br />PER CHAPTER 11B-606.5 .
<br />ACCESSIBLE ROUTE OF TRAVEL
<br />1.WHEN A BUILDING OR PORTION OF A BUILDING IS REQUIRED TO BE
<br />ACCESSIBLE OR ADAPTABLE, AN ACCESSIBLE ROUTE OF TRAVEL SHALL BE
<br />PROVIDED TO ALL PORTIONS OF THE BUILDING, TO ACCESSIBLE BUILDING
<br />ENTRANCES, AND BETWEEN THE BUILDING AND THE PUBLIC WAY.
<br />2.EXCEPT WITHIN AN INDIVIDUAL DWELLING UNIT, AN ACCESSIBLE ROUTE OF
<br />TRAVEL SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS,
<br />RESTROOMS, CLOSETS OR OTHER SPACES USED FOR SIMILAR PURPOSES.
<br />3.AT LEAST ONE ACCESSIBLE ROUTE WITHIN THE BOUNDARY OF THE SITE
<br />SHALL BE PROVIDED FROM PUBLIC TRANSPORTATION STOPS, ACCESSIBLE
<br />PARKING AND ACCESSIBLE PASSENGER LOADING ZONES, AND PUBLIC
<br />STREETS OR SIDEWALKS, TO THE ACCESSIBLE BUILDING ENTRANCES THEY
<br />SERVE.
<br />4.AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS,
<br />FACILITIES, ELEMENTS, AND SPACES THAT ARE ON THE SAME SITE.
<br />1.COMMERCIAL FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO MEET
<br />THE MINIMUM REQUIREMENTS OF THE FOLLOWING : CHAPTER 11B OF THE
<br />2022 CALIFORNIA BUILDING CODE .
<br />2.ALL ENTRANCES AND ALL EXTERIOR GROUND-LEVEL EXITS SHALL BE
<br />ACCESSIBLE IN COMPLIANCE WITH CHAPTER 11B OF THE 2022 CALIFORNIA
<br />BUILDING CODE .
<br />3.ALL BUILDING ENTRANCES SHALL BE IDENTIFIED BY A STANDARD SIGN WITH
<br />THE INTERNATIONAL SYMBOL OF ACCESSIBILITY WITH ADDITIONAL
<br />DIRECTIONAL SIGNS, AS REQUIRED. THE SYMBOL SHALL BE A WHITE FIGURE
<br />ON BLUE BACKGROUND. BRAILLE, RAISED CHARACTERS, AND PICTORIAL
<br />SYMBOL SIGNS SHALL BE USED WHEREVER SPECIFICALLY REQUIRED, AND
<br />SHALL CONFORM TO THE STANDARDS SET FORTH IN THE CODE. CHAPTER 11B
<br />OF THE 2022 CALIFORNIA BUILDING CODE .
<br />4.IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A
<br />COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY PEDESTRIAN
<br />RAMPS, PASSENGER ELEVATORS, OR SPECIAL ACCESS LIFTS IN COMPLIANCE
<br />WITH CHAPTER 11B OF THE 2022 CALIFORNIA BUILDING CODE .
<br />5.SPECIFIC WORK STATIONS NEED ONLY COMPLY WITH AISLE WIDTH (SECTION
<br />11B-403.5 ) AND FLOORS AND LEVELS (SECTION 11B-303 ), AND ENTRY WAYS
<br />SHALL BE 32" IN CLEAR WIDTH.
<br />6.AISLES SHALL NOT BE LESS THAN 36" WIDE IF SERVING ONLY ONE SIDE, AND
<br />NOT LESS THAN 42" WIDE IF SERVING BOTH SIDES. SUCH MINIMUM WIDTH
<br />SHALL BE MEASURE AT THE POINT FARTHEST FROM AN EXIT, CROSS AISLE,
<br />OR FOYER AND SHALL BE INCREASED BY 1-1/2" FOR EACH 5'-0" IN LENGTH
<br />TOWARDS THE EXIT, CROSS AISLE, OR FOYER.
<br />7.WHERE FIXED OR BUILT-IN SEATING, TABLES OR COUNTERS ARE PROVIDED
<br />FOR THE PUBLIC, AND IN GENERAL EMPLOYEE AREAS, 5 PERCENT (%) BUT
<br />NEVER LESS THAN ONE, MUST BE ACCESSIBLE AS PROVIDED IN SECTION
<br />11B-226.
<br />8.STORAGE AND CLOSET AREAS SHALL HAVE COMPLYING DOORWAYS,
<br />PROVIDING ACCESS TO ALL SUCH AREAS SHALL NOT BE LESS THAN 32" IN
<br />CLEAR WIDTH. STORAGE AREAS SHALL BE MADE ACCESSIBLE IN THE NUMBER
<br />AND DIMENSIONS PROVIDED IN SECTION 11B-805.7 .
<br />9.THE TOPS OF TABLES AND COUNTERS SHALL BE 28" TO 34" FROM THE FLOOR.
<br />WHERE A SINGLE COUNTER CONTAINS MORE THAN ONE TRANSACTION
<br />STATION, SUCH AS A BANK TELLER, AT LEAST 5 PERCENT (%), BUT NEVER
<br />LESS THAN ONE, OF EACH TYPE OF EACH STATION SHALL BE LOCATED AT
<br />SECTIONS OF COUNTER THAT IS AT LEAST 36" LONG AND NO MORE THAN 28"
<br />TO 34" HIGH. SECTION 11B-902 .
<br />10.DRINKING FOUNTAINS SHALL BE MADE ACCESSIBLE TO INDIVIDUALS WHO USE
<br />WHEELCHAIRS IN ACCORDANCE WITH THE SECTION 11B-602 AND ONE
<br />ACCESSIBLE TO THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING.
<br />11.ALL POINT-OF-SALE MACHINES USED BY CUSTOMERS FOR THE PRIMARY
<br />PURPOSE OF EXECUTING TRANSACTIONS BETWEEN THE BUSINESS ENTITY
<br />AND THE CUSTOMER, SHALL COMPLY WITH SECTION 11B-220 .
<br />GENERAL ACCESSIBILITY NOTES1 1/2" MIN.
<br />AND MAX.
<br />GRAB BAR NOTES:
<br />1.BENDING STRESS IN GRAB BAR OR SEAT INDUCED BY THE MAXIMUM
<br />BENDING MOMENT FROM THE APPLICATION OF 250 LBF SHALL BE LESS
<br />THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAR OR
<br />SEAT.
<br />2.SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF
<br />250 LBF SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE
<br />MATERIAL OF THE GRAB BAR OR SEAT. IF THE CONNECTION BETWEEN THE
<br />GRAB BAR OR SEAT AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS
<br />CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL
<br />SHEAR STRESSES SHALL BE TOTALED FOR THE COMBINED SHEAR STRESS,
<br />WHICH SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS.
<br />3.SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE FROM THE
<br />APPLICATION OF 250 LBF SHALL BE LESS THAN THE ALLOWABLE LATERAL
<br />LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE OR THE
<br />SUPPORTING STRUCTURE, WHATEVER IS THE SMALLER ALLOWABLE LOAD.
<br />4.TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF
<br />250 LBF PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF 250
<br />LBF SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN
<br />THE FASTENER AND THE SUPPORTING STRUCTURE.
<br />24 TYP. GRAB BAR DETAIL & NOTES
<br />SCALE: 3" = 1'-0"
<br />5 PEDESTRIAN PROTECTION
<br />SCALE: 3/4" = 1'-0"
<br />6"
<br />MA
<br />X
<br />33
<br />"
<br />FINISH FLOOR
<br />FINISH FACE OF WALL
<br />SIDEFRONT
<br />18"
<br />MIN.
<br />32"
<br />MIN. CLEAR
<br />18
<br />"
<br />MI
<br />N
<br />.
<br />PLAN
<br />FINISH FACE
<br />OF WALL
<br />2 TURNING SPACE
<br />SCALE: 1/4" = 1'-0"
<br />60"
<br />60"
<br />36
<br />"
<br />60
<br />"
<br />36"24
<br />"
<br />12"12"
<br />CIRCULAR T-SHAPED
<br />3 CLEAR FLOOR SPACE
<br />SCALE: 1/4" = 1'-0"
<br />FORWARD PARALLEL
<br />30"
<br />48
<br />"
<br />30
<br />"
<br />48"
<br />4 KNEE AND TOE CLEARANCE
<br />SCALE: 1/4" = 1'-0"
<br />TOE CLEARANCE
<br />KNEE CLEARANCE
<br />ELEVATION PLAN
<br />PLANELEVATION
<br />9"
<br />MI
<br />N
<br />.
<br />6"
<br />MIN.
<br />9"
<br />MI
<br />N
<br />.
<br />8"
<br />MIN.
<br />27
<br />"
<br />MI
<br />N
<br />.
<br />11"
<br />MIN.
<br />30
<br />"
<br />MI
<br />N
<br />.
<br />17"-25"
<br />30
<br />"
<br />MI
<br />N
<br />.
<br />25"
<br />MAX.
<br />7 PROTRUDING OBJECTS
<br />SCALE: 1/4" = 1'-0"
<br />X
<br />≥ 8
<br />0
<br />"
<br />>
<br />2
<br />7
<br />"
<br />4"
<br />MAX.
<br />15
<br />"
<br />MI
<br />N
<br />.
<br />48
<br />"
<br />MA
<br />X
<br />.
<br />48
<br />"
<br />MA
<br />X
<br />.
<br />20"
<br />MAX.
<br />44
<br />"
<br />MA
<br />X
<br />.
<br />>20"-25"
<br />15
<br />"
<br />MI
<br />N
<br />.
<br />48
<br />"
<br />MA
<br />X
<br />.
<br />46
<br />"
<br />MA
<br />X
<br />.
<br />>10"-24"
<br />34
<br />"
<br />MA
<br />X
<br />.
<br />48
<br />"
<br />MA
<br />X
<br />.
<br />34
<br />"
<br />MA
<br />X
<br />.
<br />10" MAX.
<br />6 REACH RANGES
<br />SCALE: 1/4" = 1'-0"
<br />FORWARD REACH
<br />SIDE REACH
<br />UNOBSTRUCTED OBSTRUCTED OBSTRUCTED
<br />OBSTRUCTEDOBSTRUCTEDUNOBSTRUCTED
<br />10" MAX.
<br />15 CLEARANCES - MANUAL SWING DOORS
<br />SCALE: 1/4" = 1'-0"
<br />FRONT APPROACHPULL SIDE
<br />FRONT APPROACHPUSH SIDE
<br />HINGE APPROACHPULL SIDELATCH APPROACHPULL SIDE
<br />HINGE APPROACHPUSH SIDELATCH APPROACHPUSH SIDE
<br />HINGE APPROACHPULL SIDE
<br />18"
<br />MIN.
<br />48
<br />"
<br />MI
<br />N
<br />.
<br />12"
<br />MIN.*
<br />42
<br />"
<br />MI
<br />N
<br />.
<br />22"
<br />MIN.
<br />HINGE APPROACHPUSH SIDE
<br />48
<br />"
<br />MI
<br />N
<br />.
<br />22"
<br />MIN.12"
<br />MIN.42
<br />"
<br />MI
<br />N
<br />.
<br />24"
<br />MIN.
<br />42"
<br />MIN.
<br />36"
<br />MIN.
<br />24"
<br />MIN.
<br />* IF BOTH
<br />CLOSER AND
<br />LATCH ARE
<br />PROVIDED
<br />* 48" MIN. IF
<br />CLOSER IS
<br />PROVIDED
<br />* 54" MIN. IF
<br />CLOSER IS
<br />PROVIDED
<br />IF BOTH
<br />CLOSER AND
<br />LATCH ARE
<br />PROVIDED
<br />54
<br />"
<br />MI
<br />N
<br />.
<br />60
<br />"
<br />MI
<br />N
<br />.
<br />60
<br />"
<br />MI
<br />N
<br />.
<br />48
<br />"
<br />MI
<br />N
<br />.
<br />*
<br />9 CLEARANCES - SLIDING & FOLDING DOORS
<br />SCALE: 1/4" = 1'-0"
<br />FRONT APPROACHPOCKET ORHINGE APPROACH STOP ORLATCH APPROACH
<br />8 CLEARANCES - W/O DOORS
<br />SCALE: 1/4" = 1'-0"
<br />FRONT APPROACH SIDE APPROACH
<br />20 CLEARANCES - RECESSED DOORS
<br />SCALE: 1/4" = 1'-0"
<br />PULL SIDE
<br />PUSH SIDE
<br />W/CLOSER & LATCH
<br />18"
<br />MIN.
<br />X
<br />>
<br />
<br />8
<br />"
<br />12"
<br />MIN.*
<br />60
<br />"
<br />MI
<br />N
<br />.
<br />48
<br />"
<br />MI
<br />N
<br />.
<br />X
<br />>
<br />
<br />8
<br />"
<br />PUSH SIDE
<br />48
<br />"
<br />MI
<br />N
<br />.
<br />X
<br />>
<br />
<br />8
<br />"
<br />21 CLEAR WIDTH OF DOORWAYS
<br />SCALE: 1/4" = 1'-0"
<br />HINGED DOOR SLIDING DOOR
<br />FOLDING DOOR DOORWAYS W/O DOORS
<br />32"
<br />MIN.
<br />90°32"
<br />MIN.
<br />36"
<br />MIN.
<br />32"
<br />MIN.
<br />>
<br />2
<br />4
<br />"
<br />22"
<br />MIN.
<br />48
<br />"
<br />MI
<br />N
<br />.
<br />42
<br />"
<br />MI
<br />N
<br />.
<br />24"
<br />MIN.
<br />42
<br />"
<br />MI
<br />N
<br />.
<br />\A1;MIN.
<br />26 DRINKING FOUNTAINS
<br />SCALE: 1/4" = 1'-0"
<br />SECTION
<br />36
<br />"
<br />MA
<br />X
<br />.
<br />WH
<br />E
<br />E
<br />L
<br />C
<br />H
<br />A
<br />I
<br />R
<br />AC
<br />C
<br />E
<br />S
<br />S
<br />I
<br />B
<br />L
<br />E
<br />38
<br />"
<br />-
<br />4
<br />3
<br />"
<br />ST
<br />A
<br />N
<br />D
<br />I
<br />N
<br />G
<br />PE
<br />R
<br />S
<br />O
<br />N
<br />15"
<br />MIN.
<br />5"
<br />MAX.
<br />15
<br />"
<br />MI
<br />N
<br />.
<br />5"
<br />MA
<br />X
<br />.
<br />PLAN
<br />12 TOILET LOCATION
<br />SCALE: 1/4" = 1'-0"
<br />17"-18"17"-18"
<br />AMBULATORY ACCESSIBLE TOILETSACCESSIBLE TOILETS
<br />11 TOILET SEAT HEIGHT
<br />SCALE: 1/4" = 1'-0"
<br />17
<br />"
<br />-
<br />1
<br />9
<br />"
<br />13 TOILET GRAB BARS
<br />SCALE: 1/4" = 1'-0"
<br />33
<br />"
<br />-
<br />3
<br />6
<br />"
<br />39
<br />"
<br />-
<br />4
<br />1
<br />"
<br />18
<br />"
<br />MI
<br />N
<br />.
<br />39"-41"
<br />12"
<br />MAX.
<br />42"
<br />MIN.
<br />54"
<br />MIN.
<br />12"
<br />MAX.
<br />24"
<br />MIN.
<br />36"
<br />MIN.
<br />33
<br />"
<br />-
<br />3
<br />6
<br />"
<br />SIDE WALL REAR WALL
<br />14 TOILET COMPARTMENT
<br />SCALE: 1/4" = 1'-0"
<br />56
<br />"
<br />MI
<br />N
<br />.
<br />60"
<br />MIN.
<br />6"
<br />MIN.
<br />6"
<br />MI
<br />N
<br />.
<br />TOE CLEARANCE
<br />25 URINALS
<br />SCALE: 1/4" = 1'-0"
<br />17
<br />"
<br />MA
<br />X
<br />.
<br />13 1/2"
<br />MIN.
<br />18 LAVATORIES
<br />SCALE: 1/4" = 1'-0"
<br />34
<br />"
<br />
<br />M
<br />A
<br />X
<br /> 2
<br />7
<br />"
<br />
<br />M
<br />I
<br />N
<br />.
<br />9"
<br />MI
<br />N
<br />11"
<br />MIN.
<br />9"
<br />MIN.
<br />8"
<br />MIN.
<br />WATER SUPPLY AND
<br />DRAINPIPES UNDER
<br />LAVATORIES AND SINKS
<br />SHALL BE INSULATED OR
<br />OTHERWISE CONFIGURED
<br />TO PROTECT AGAINST
<br />CONTACT. THERE SHALL BE
<br />NO SHARP OR ABRASIVE
<br />SURFACES UNDER
<br />LAVATORIES OR SINKS.
<br />SECTIONPLAN
<br />30"
<br />48
<br />"
<br />SECTIONPLAN
<br />CLEAR
<br />FLOOR
<br />SPACE
<br />30"
<br />MIN.
<br />48
<br />"
<br />MI
<br />N
<br />.
<br />CLEAR
<br />FLOOR
<br />SPACE
<br />17
<br />"
<br />MI
<br />N
<br />19
<br />"
<br />MA
<br />X
<br />.
<br />16 ACCESSORY MOUNTING HEIGHTS
<br />SCALE: 1/4" = 1'-0"
<br />HANDDRYER
<br />TOWELDISPENSER
<br />BABYCHANGINGSTATION
<br />HAND SANITIZER/SOAP DISPENSER
<br />MIRROR
<br />SANITARYWASTERECEPTACLE
<br />TOILET SEATCOVERDISPENSER
<br />28
<br />
<br />3
<br />/
<br />4
<br />"
<br />44
<br />"
<br />M
<br />A
<br />X
<br />.
<br />HA
<br />N
<br />D
<br />L
<br />E
<br />
<br />A
<br />R
<br />E
<br />A
<br />HANDLES ARE
<br />LOCATED ON
<br />BOTH SIDE OF
<br />THE UNIT
<br />44
<br />"
<br />38
<br />
<br />1
<br />/
<br />2
<br />"
<br />48
<br />"
<br />
<br />M
<br />A
<br />X
<br />.
<br />OP
<br />E
<br />R
<br />A
<br />B
<br />L
<br />E
<br />PA
<br />R
<br />T
<br />S
<br />40
<br />"
<br />48
<br />"
<br />8"
<br />40
<br />"
<br />
<br />M
<br />A
<br />X
<br />.
<br />BO
<br />T
<br />T
<br />O
<br />M
<br />
<br />O
<br />F
<br />RE
<br />F
<br />L
<br />E
<br />C
<br />T
<br />I
<br />V
<br />E
<br />SU
<br />R
<br />F
<br />A
<br />C
<br />E
<br />15
<br />"
<br />
<br />M
<br />I
<br />N
<br />.
<br />OP
<br />E
<br />R
<br />A
<br />B
<br />L
<br />E
<br />PA
<br />R
<br />T
<br />S
<br />OTHER FIXTURES
<br />NOT ALLOWED
<br />WITHIN THIS AREA
<br />18
<br />"
<br />48
<br />"
<br />48
<br />"
<br />6'
<br />-
<br />8
<br />"
<br />8"
<br />TYPICAL LOCATION FOR LIGHT SWITCHES, DIMMERS, EGRESS BUTTONS,
<br />THERMOSTATS, ETC. AND POWER AND TELEPHONE OUTLETS AT WALL OR COLUMN
<br />44
<br />"
<br />6'
<br />-
<br />8
<br />"
<br />6"
<br />42
<br />"
<br />6'
<br />-
<br />8
<br />"
<br />B
<br />TYPICAL LOCATION FOR OUTLETS, SWITCHES
<br />AND THERMOSTATS, ETC. AT CREDENZA OR
<br />COUNTERTOP
<br />TYPICAL LOCATION FOR ONE OR TWO
<br />MOUNTED FIRE ALARM DEVICES / VISUAL
<br />ALARM FEC
<br />℄
<br />STROBE (AS
<br />APPLICABLE)
<br />THERMOSTAT
<br />OR INTERCOM
<br />LIGHT SWITCHES
<br />DIMMERS, POWER
<br />AND TELEPHONE
<br />RECEPTACLE, ETC.
<br />CREDENZA OR
<br />COUNTER - REFER
<br />TO ELEV./DETAILS
<br />FINISH FLOOR
<br />FIRE ALARM
<br />(SPEAKER/
<br />STROBE OR
<br />STROBE ONLY)
<br />FIRE
<br />EXTINGUISHER
<br />FINISH FLOOR
<br />DOOR FRAME EDGE
<br />STROBE (AS APPLICABLE)
<br />THERMOSTAT, INTERCOM OR SECOND ROW OF
<br />RECEPTACLES CENTER TO CLUSTER (WHEN USING
<br />DIMMERS, LOCATE THERMOSTAT AT OPPOSITE
<br />SIDE OF DOOR)
<br />LIGHT SWITCH, DIMMERS, EGRESS BUTTON,
<br />INTERCOM BUTTON, CARD READER, ETC.
<br />DOOR
<br />LEVER, PULL
<br />FINISH FLOOR
<br />POWER AND TELEPHONE RECEPTACLE AND
<br />CLUSTER VERTICALLY MOUNTED
<br />℄
<br />℄℄
<br />44
<br />"
<br />\A
<br />1
<br />;
<br />4
<br />4
<br />"
<br />48"
<br />AFF MIN.
<br />60"
<br />AFF MAX.
<br />CENTERED
<br />ON RAISED
<br />CHARACTERS
<br />18"
<br />MIN.
<br />22 TACTILE SIGN LOCATIONS
<br />SCALE: 1/4" = 1'-0"
<br />18
<br />"
<br />MI
<br />N
<br />.
<br />TACTILE SIGN NOTES:
<br />1.WHERE A SIGN CONTAINING RAISED
<br />CHARACTERS AND BRAILLE IS PROVIDED AT A
<br />DOOR, THE SIGN SHALL BE ALONGSIDE THE
<br />DOOR AT THE LATCH SIDE.
<br />2.BRAILLE SHALL BE MOUNTED 48 INCHES
<br />MINIMUM AND 60 INCHES MAXIMUM ABOVE
<br />THE FLOOR, MEASURED TO THE BASELINE OF
<br />THE BRAILLE CELLS AS PER SECTION 703.4.5.
<br />3.SIGNS SHALL BE IN CONTRASTING COLOR AND
<br />NON-GLARE.
<br />THIS DRAWING IS A REPRESENTATIVE SUMMARY OF THE REQUIREMENTS OF THE ADA
<br />STANDARDS THAT MAY BE APPLICABLE TO THE PROJECT. WHERE SPECIFIC DIMENSIONAL
<br />INFORMATION AND CLEARANCES ARE NOT NOTED ON THE DRAWINGS, CONSTRUCT TO THE
<br />CLEARANCES AND TOLERANCES SHOWN ON THIS SHEET. WHERE DRAWINGS SPECIFICALLY
<br />INDICATE DIFFERENT OR CONFLICTING INFORMATION TO THE STANDARDS DEPICTED ON
<br />THIS SHEET, CONSTRUCT USING THE MORE STRINGENT REQUIREMENT OR CONTACT THE
<br />ARCHITECT FOR RESOLUTION
<br />WOMEN
<br />WOMEN
<br />MEN
<br />MEN
<br />9"9"
<br />56
<br />"
<br />
<br />M
<br />I
<br />N
<br />.
<br />60
<br />'
<br />
<br />M
<br />A
<br />X
<br />.
<br />56
<br />"
<br />
<br />M
<br />I
<br />N
<br />.
<br />60
<br />"
<br />
<br />M
<br />A
<br />X
<br />.
<br />5'
<br />-
<br />0
<br />"
<br />
<br />M
<br />A
<br />X
<br />.
<br />BA
<br />S
<br />E
<br />L
<br />I
<br />N
<br />E
<br />
<br />T
<br />A
<br />C
<br />T
<br />I
<br />L
<br />E
<br />
<br />A
<br />R
<br />E
<br />A
<br />12"
<br />12"6"
<br />MI
<br />N
<br />1'-6"
<br />CLEAR FLOOR
<br />SPACE
<br />℄
<br />G.C. TO PROVIDE RESTROOM SIGN WITH RAISED AND
<br />BRAILLE CHARACTERS AND PICTOGRAM SYMBOL AT
<br />CORRIDOR SIDE OF TOILET ROOM DOOR AS PER STATE
<br />AND LOCAL ACCESSIBILITY CODE.
<br />℄
<br />1'-6"
<br />CLEAR FLOOR
<br />SPACE
<br />5'
<br />-
<br />0
<br />"
<br />
<br />M
<br />A
<br />X
<br />.
<br />BA
<br />S
<br />E
<br />L
<br />I
<br />N
<br />E
<br />
<br />T
<br />A
<br />C
<br />T
<br />I
<br />L
<br />E
<br />
<br />A
<br />R
<br />E
<br />A
<br />6"
<br />MI
<br />N
<br />℄
<br />℄
<br />℄
<br />10 TYPICAL MOUNTING HEIGHTS
<br />SCALE: 1/4" = 1'-0"
<br />℄
<br />℄
<br />℄
<br />℄
<br />℄
<br />A
<br />4" MIN.
<br />C
<br />48
<br />"
<br />
<br />M
<br />A
<br />X
<br />.
<br />OP
<br />E
<br />R
<br />A
<br />B
<br />L
<br />E
<br />PA
<br />R
<br />T
<br />S
<br />15
<br />"
<br />
<br />M
<br />I
<br />N
<br />.
<br />OP
<br />E
<br />R
<br />A
<br />B
<br />L
<br />E
<br />PA
<br />R
<br />T
<br />S
<br />TACTILE CHARACTER HEIGHTABOVE FLOORCLEAR FLOOR SPACE FORTACTILE SIGNS AT DOORS
<br />℄
<br />INTERNATIONAL SYMBOL OFACCESSIBILITY
<br />17 TOILET PAPER DISPENSERS
<br />SCALE: 1/4" = 1'-0"
<br />PROTRUDING DISPENSERBELOW GRAB BAR
<br />18
<br />"
<br />MI
<br />N
<br />.
<br />1
<br />1
<br />/
<br />2
<br />"
<br />MI
<br />N
<br />.
<br />42"
<br />MAX.
<br />24"
<br />MIN.
<br />\A1;MIN.
<br />PROTRUDING DISPENSERABOVE GRAB BAR
<br />24"
<br />MIN.
<br />36"
<br />MAX.
<br />12
<br />"
<br />MI
<br />N
<br />.
<br />48
<br />"
<br />MA
<br />X
<br />.
<br />\A1;MAX.
<br />RECESSED DISPENSER
<br />18
<br />"
<br />MI
<br />N
<br />.
<br />48
<br />"
<br />MA
<br />X
<br />.
<br />42"
<br />MAX.
<br />24"
<br />MIN.
<br />36"
<br />MAX.
<br />7"-9"7"-9"
<br />24"
<br />MIN.
<br />℄℄
<br />1.6" - 2.4"
<br />1.
<br />6
<br />"
<br />
<br />-
<br />
<br />2
<br />.
<br />4
<br />"
<br />0.65"
<br />MIN.
<br />50% - 65%
<br />BASE DIAMETER
<br />0.
<br />2
<br />"0.9" - 1.4"
<br />GENERAL NOTES:
<br />1.DETECTABLE WARNING SURFACES
<br />SHALL HAVE TRUNCATED DOMES
<br />COMPLYING WITH SECTION705.5.
<br />2.DETECTABLE WARNING SURFACES
<br />SHALL CONTRAST VISUALLY WITH
<br />ADJACENT SURFACES, EITHER
<br />LIGHT-ON-DARK OR DARK-ON-LIGHT.
<br />3.TRUNCATED DOMES SHALL HAVE A
<br />BASE DIAMETER OF 0.9 INCH
<br />MINIMUM AND 1.4 INCH MAXIMUM,
<br />AND A TOP DIAMETER OF 50%
<br />MINIMUM AND 65% MAXIMUM OF
<br />THE BASE DIAMETER.
<br />4.TRUNCATED DOMES SHALL HAVE A
<br />HEIGHT OF 0.2 INCH.
<br />5.TRUNCATED DOMES TO BE
<br />BOLT-DOWN.
<br />19 TRUNCATED DOMES DETAIL
<br />SCALE: 6" = 1'-0"
<br />HEIGHT OF RAISEDCHARACTERS POSITION OF BRAILLE
<br />3/
<br />8
<br />"
<br />MI
<br />N
<br />.
<br />3/
<br />8
<br />"
<br />MI
<br />N
<br />.
<br />5/
<br />8
<br />"
<br />
<br />-
<br />
<br />2
<br />"
<br />GENERAL NOTES:
<br />1.RAISED CHARACTERS SHALL BE 1/32" MINIMUM ABOVE THEIR BACKGROUND, SANS SERIF
<br />STYLE AND UPPERCASE.
<br />2.RAISED CHARACTERS SHALL BE 48 INCHES MINIMUM ABOVE THE FLOOR, MEASURED TO THE
<br />BASELINE OF THE LOWEST RAISED CHARACTER AND 60 INCHES MAXIMUM ABOVE THE FLOOR,
<br />MEASURED TO THE BASELINE OF THE HIGHEST RAISED CHARACTER.
<br />3.BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH 703.3 AND 703.4.
<br />4.BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT. IF TEXT IS MULTI-LINED,
<br />BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT. (703.4.4)
<br />5.BRAILLE SHALL BE 48 INCHES MINIMUM AND 60 INCHES MAXIMUM ABOVE THE FLOOR,
<br />MEASURED TO THE BASELINE OF THE BRAILLE CELLS.
<br />6.CHARACTERS OR BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD.
<br />23 TACTILE SIGN DETAILS
<br />SCALE: 6" = 1'-0"
<br />1 CHANGES IN LEVEL
<br />SCALE: 1'-0" = 1'-0"
<br />1/
<br />4
<br />"
<br />(M
<br />A
<br />X
<br />.
<br />)
<br />(A) VERTICAL
<br />(B) BEVELED
<br />1/
<br />2
<br />"
<br />(M
<br />A
<br />X
<br />.
<br />)
<br />1/
<br />4
<br />"
<br />(M
<br />A
<br />X
<br />.
<br />)
<br />1/
<br />4
<br />"
<br />(M
<br />A
<br />X
<br />.
<br />)
<br />1
<br />2 1/
<br />4
<br />"
<br />(M
<br />A
<br />X
<br />.
<br />)
<br />1
<br />2
<br />1801 EAST DYER RD.
<br />SANTA ANA, CA 92705
<br />CONSULTANT
<br />PROJECT
<br />2022.0315.00
<br />54,016 SF
<br />OWNER
<br />PHONE:(404) 471-1634
<br />129
<br />08/01/2024
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />L
<br />I
<br />F
<br />O
<br />R
<br />N
<br />I
<br />A
<br />2023 Q2
<br />ALL ARCHITECTURAL AND ENGINEERINGDRAWINGS ARE IN CONFIDENCE ANDDISSEMINATION MAY NOT BE MADE WITHOUTPRIOR WRITTEN CONSENT OF THE ARCHITECT.ALL COMMON LAW RIGHTS OF COPYRIGHT ANDOTHERWISE ARE HEREBY SPECIFICALLY RESERVED
<br />2500 WINDY RIDGE PARKWAY, SE
<br />ATLANTA, GA 30339
<br />ISSUE
<br />DRAWN:
<br />CHECKED:
<br />SHEET
<br />SEAL
<br />AREA :
<br />JOB NUMBER:
<br />ISSUE DATE:
<br />STORE NUMBER:
<br />ST
<br />O
<br />R
<br />E
<br />
<br />#
<br />1
<br />2
<br />9
<br />PROTOTYPE:
<br />CITY APPROVAL STAMP
<br />PERMIT SET 08/01/2024
<br />LICENSE: #C-39437
<br />EXP: 07/31/2025
<br />1 REVISION 1 12/12/2024
<br />1 REVISION 1 (RE-ISSUE)01/10/2025
<br />ACCESSIBILITY NOTES
<br />G002
<br />KLS
<br />AJB
<br />1
<br />1
<br />1
<br />1
<br />1
<br />1801 E Dyer Rd
<br />3/11/2025
|