Laserfiche WebLink
TYPICAL ABBREVIATIONS <br />DESCRIPTION <br />ABV.ABOVE <br />A.C.T.ACOUSTICAL CEILING TILE <br />A.D.A.AMERICANS WITH DISABILITIES <br />ACT <br />ADD'L ADDITIONAL <br />A.F.F.ABOVE FINISH FLOOR <br />A.S.T.M.AMERICAN SOCIETY FOR TESTING <br />AND MATERIALS <br />BD.BOARD <br />BM.BEAM <br />B.O.BOTTOM OF <br />C.J.CONTROL JOINT <br />C.L.CENTERLINE <br />CLG.CEILING <br />CLR.CLEAR <br />C.M.U.CONCRETE MASONRY UNIT <br />C.O.CLEANOUT <br />COL.COLUMN <br />CONC.CONCRETE <br />C.W.COLD WATER <br />DEMO DEMOLISH OR DEMOLITION <br />DIA.DIAMETER <br />DIM.DIMENSION <br />DS.DOWNSPOUT <br />DN.DOWN <br />DWG.DRAWING <br />EA.EACH <br />E.A.EXHAUST AIR <br />E.I.F.S.EXTERIOR FINISH AND INSULATION <br />SYSTEM <br />E.J.EXPANSION JOINT <br />ELEV.ELEVATION <br />EQ.EQUAL <br />EXT.EXTERIOR <br />F.D.FLOOR DRAIN OR FIRE DAMPER OR <br />FIRE DEPARTMENT <br />F.E.FIRE EXTINGUISHER <br />F.F.FINISH FLOOR <br />FIN.FINISH <br />FIXT.FIXTURE <br />FLR.FLOOR <br />F.O.FINISH OPENING <br />F.R.T.FIRE RETARDANT TREATED <br />FT.FEET <br />GA.GAUGE <br />G.C.GENERAL CONTRACTOR <br />GYP.GYPSUM <br />HB.HOSE BIB <br />HDW.HARDWARE <br />H.M.HOLLOW METAL <br />HT.HEIGHT <br />HTR.HEATER <br />H.V.A.C.HEATING, VENTILATION AND AIR <br />CONDITIONING <br />H.W.HOT WATER <br />I.B.C.INTERNATIONAL BUILDING CODE <br />I.D.INSIDE DIAMETER <br />I.E.C.C.INTERNATIONAL ENERGY <br />CONSERVATION CODE <br />I.F.C.INTERNATIONAL FIRE CODE <br />I.M.C.INTERNATIONAL MECHANICAL <br />CODE <br />IN.INCH <br />INFO INFORMATION <br />INSUL.INSULATION <br />INT.INTERIOR <br />I.P.C.INTERNATIONAL PLUMBING CODE <br />kV KILOVOLT <br />DESCRIPTION <br />kVA KILOVOLT-AMPS <br />kW KILOWATT <br />kWH KILOWATT-HOUR <br />LL.LANDLORD <br />MAX.MAXIMUM <br />M.D.F.MEDIUM DENSITY FIBERBOARD <br />MIN.MINIMUM <br />M.O.MASONRY OPENING <br />MTL.METAL <br />N/A NOT APPLICABLE <br />NEC.NATIONAL ELECTRICAL CODE <br />NFPA.NATIONAL FIRE PROTECTION <br />ASSOCIATION <br />N.I.C.NOT IN CONTRACT <br />NOM.NOMINAL <br />N.T.S.NOT TO SCALE <br />O.C.ON CENTER <br />O.D.OUTSIDE DIAMETER <br />OPP.OPPOSITE <br />PLBG.PLUMBING <br />PLY.PLYWOOD <br />PNL.PANEL <br />PNT.PAINT <br />PR PAIR <br />P.S.I.POUNDS PER SQUARE INCH <br />P.S.F.POUNDS PER SQUARE FOOT <br />PT.POINT <br />P.V.C.POLY VINYL CHLORIDE <br />r.RADIUS <br />R.A.RETURN AIR <br />R.C.P.REFLECTED CEILING PLAN <br />RD ROUND <br />R.O.ROUGH OPENING <br />REINF.REINFORCED OR REINFORCING <br />REQ'D REQUIRED <br />REV.REVISION <br />RGH.ROUGH <br />R.T.U.ROOF TOP UNIT <br />R.W.L.RAIN WATER LEADER <br />S.A.SUPPLY AIR <br />S.F.SQUARE FEET <br />SIM.SIMILAR <br />SPEC.SPECIFIED OR SPECIFICATION <br />S.Q.SQUARE <br />S.S.STAINLESS STEEL <br />STC.SOUND TRANSMISSION <br />COEFFICIENT <br />STD.STANDARD <br />STL.STEEL <br />STRUCT.STRUCTURE <br />SUSP.SUSPENDED <br />T&G TONGUE AND GROOVE <br />TA TO ABOVE <br />T.B.D.TO BE DETERMINED <br />TEMP.TEMPORARY <br />T.O.TOP OF <br />TPO.THERMOPLASTIC POLYOLEFIN <br />TYP.TYPICAL <br />U.L.UNDERWRITER'S LABORATORY <br />U.N.O.UNLESS NOTED OTHERWISE <br />U/S UNDERSIDE <br />V.I.F.VERIFY IN FIELD <br />V.C.T.VINYL COMPOSITION TILE <br />W/WITH <br />W/O WITHOUT <br />WD.WOOD <br />W.H.WATER HEATER <br />W.P.WEATHER PROOF <br />ACCESSIBILITY GUIDELINES <br />1.AN UNOBSTRUCTED TURNING SPACE OF 60" IN DIAMETER SHALL BE <br />PROVIDED WITHIN AN ACCESSIBLE TOILET ROOM. <br />2.A DOOR, IF PROVIDED, SHALL NOT ENCROACH INTO THE REQUIRED <br />CLEAR FLOOR SPACE IN FRONT OF THE WATER CLOSET. <br />3.THE DIAMETER OR WIDTH OF THE GRIPPING SURFACES OF THE <br />GRAB BARS SHALL BE 1-1/4" TO 1-1/2" AND THE SPACE BETWEEN THE <br />WALL AND THE GRAB BAR SHALL BE 1-1/2". <br />4.CONTROLS AND SWITCHES ON WALLS ARE TO BE PLACED A <br />MAXIMUM OF 48" ABOVE THE FINISH FLOOR. ELECTRICAL <br />RECEPTACLES ON WALLS SHALL BE PLACED NO LESS THAN 15" <br />ABOVE THE FINISH FLOOR. DIMENSIONS ARE TO THE HIGHEST <br />OPERABLE PART OF CONTROLS AND THE LOWEST OPERABLE PART <br />OF CONTROLS AND THE LOWEST OPERABLE PART OF <br />RECEPTACLES. <br />5.ALL CLEARANCES, MOUNTING HEIGHTS, PATHS OF TRAVEL ETC. <br />SHALL BE PER CHAPTER 11B OF THE 2022 CALIFORNIA BUILDING <br />CODE. <br />6.IN BREAK ROOM, SINK SHALL BE MOUNTED WITH THE HIGHER OF <br />THE RIM OR COUNTER SURFACE 34" MAX. ABOVE FINISH FLOOR AND <br />WITH AN 18" MIN. TO THE CENTER FROM ANY ADJACENT WALL. <br />PROVIDE A 30" X 48" CLEAR FLOOR SPACE PER CHAPTER 11B OF THE <br />2022 CALIFORNIA BUILDING CODE AND KNEE AND TOE SPACE PER <br />CHAPTER 11B-306 ALLOWING FORWARD APPROACH. BREAK ROOM <br />FAUCET CONTROLS SHALL BE OPERABLE WITH ONE HAND AND NOT <br />REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST <br />PER CHAPTER 11B-309 . OPERABLE FORCE SHALL NOT EXCEED 5 <br />POUNDS. WATER SUPPLY AND DRAIN PIPES SHALL BE INSULATED OR <br />OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE <br />SHALL BE NO SHARP OR ABRASIVE SURFACES UNDER SINKS PER <br />PER CHAPTER 11B-606.5 . <br />ACCESSIBLE ROUTE OF TRAVEL <br />1.WHEN A BUILDING OR PORTION OF A BUILDING IS REQUIRED TO BE <br />ACCESSIBLE OR ADAPTABLE, AN ACCESSIBLE ROUTE OF TRAVEL SHALL BE <br />PROVIDED TO ALL PORTIONS OF THE BUILDING, TO ACCESSIBLE BUILDING <br />ENTRANCES, AND BETWEEN THE BUILDING AND THE PUBLIC WAY. <br />2.EXCEPT WITHIN AN INDIVIDUAL DWELLING UNIT, AN ACCESSIBLE ROUTE OF <br />TRAVEL SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, <br />RESTROOMS, CLOSETS OR OTHER SPACES USED FOR SIMILAR PURPOSES. <br />3.AT LEAST ONE ACCESSIBLE ROUTE WITHIN THE BOUNDARY OF THE SITE <br />SHALL BE PROVIDED FROM PUBLIC TRANSPORTATION STOPS, ACCESSIBLE <br />PARKING AND ACCESSIBLE PASSENGER LOADING ZONES, AND PUBLIC <br />STREETS OR SIDEWALKS, TO THE ACCESSIBLE BUILDING ENTRANCES THEY <br />SERVE. <br />4.AT LEAST ONE ACCESSIBLE ROUTE SHALL CONNECT ACCESSIBLE BUILDINGS, <br />FACILITIES, ELEMENTS, AND SPACES THAT ARE ON THE SAME SITE. <br />1.COMMERCIAL FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO MEET <br />THE MINIMUM REQUIREMENTS OF THE FOLLOWING : CHAPTER 11B OF THE <br />2022 CALIFORNIA BUILDING CODE . <br />2.ALL ENTRANCES AND ALL EXTERIOR GROUND-LEVEL EXITS SHALL BE <br />ACCESSIBLE IN COMPLIANCE WITH CHAPTER 11B OF THE 2022 CALIFORNIA <br />BUILDING CODE . <br />3.ALL BUILDING ENTRANCES SHALL BE IDENTIFIED BY A STANDARD SIGN WITH <br />THE INTERNATIONAL SYMBOL OF ACCESSIBILITY WITH ADDITIONAL <br />DIRECTIONAL SIGNS, AS REQUIRED. THE SYMBOL SHALL BE A WHITE FIGURE <br />ON BLUE BACKGROUND. BRAILLE, RAISED CHARACTERS, AND PICTORIAL <br />SYMBOL SIGNS SHALL BE USED WHEREVER SPECIFICALLY REQUIRED, AND <br />SHALL CONFORM TO THE STANDARDS SET FORTH IN THE CODE. CHAPTER 11B <br />OF THE 2022 CALIFORNIA BUILDING CODE . <br />4.IN BUILDINGS AND FACILITIES, FLOORS OF A GIVEN STORY SHALL BE A <br />COMMON LEVEL THROUGHOUT, OR SHALL BE CONNECTED BY PEDESTRIAN <br />RAMPS, PASSENGER ELEVATORS, OR SPECIAL ACCESS LIFTS IN COMPLIANCE <br />WITH CHAPTER 11B OF THE 2022 CALIFORNIA BUILDING CODE . <br />5.SPECIFIC WORK STATIONS NEED ONLY COMPLY WITH AISLE WIDTH (SECTION <br />11B-403.5 ) AND FLOORS AND LEVELS (SECTION 11B-303 ), AND ENTRY WAYS <br />SHALL BE 32" IN CLEAR WIDTH. <br />6.AISLES SHALL NOT BE LESS THAN 36" WIDE IF SERVING ONLY ONE SIDE, AND <br />NOT LESS THAN 42" WIDE IF SERVING BOTH SIDES. SUCH MINIMUM WIDTH <br />SHALL BE MEASURE AT THE POINT FARTHEST FROM AN EXIT, CROSS AISLE, <br />OR FOYER AND SHALL BE INCREASED BY 1-1/2" FOR EACH 5'-0" IN LENGTH <br />TOWARDS THE EXIT, CROSS AISLE, OR FOYER. <br />7.WHERE FIXED OR BUILT-IN SEATING, TABLES OR COUNTERS ARE PROVIDED <br />FOR THE PUBLIC, AND IN GENERAL EMPLOYEE AREAS, 5 PERCENT (%) BUT <br />NEVER LESS THAN ONE, MUST BE ACCESSIBLE AS PROVIDED IN SECTION <br />11B-226. <br />8.STORAGE AND CLOSET AREAS SHALL HAVE COMPLYING DOORWAYS, <br />PROVIDING ACCESS TO ALL SUCH AREAS SHALL NOT BE LESS THAN 32" IN <br />CLEAR WIDTH. STORAGE AREAS SHALL BE MADE ACCESSIBLE IN THE NUMBER <br />AND DIMENSIONS PROVIDED IN SECTION 11B-805.7 . <br />9.THE TOPS OF TABLES AND COUNTERS SHALL BE 28" TO 34" FROM THE FLOOR. <br />WHERE A SINGLE COUNTER CONTAINS MORE THAN ONE TRANSACTION <br />STATION, SUCH AS A BANK TELLER, AT LEAST 5 PERCENT (%), BUT NEVER <br />LESS THAN ONE, OF EACH TYPE OF EACH STATION SHALL BE LOCATED AT <br />SECTIONS OF COUNTER THAT IS AT LEAST 36" LONG AND NO MORE THAN 28" <br />TO 34" HIGH. SECTION 11B-902 . <br />10.DRINKING FOUNTAINS SHALL BE MADE ACCESSIBLE TO INDIVIDUALS WHO USE <br />WHEELCHAIRS IN ACCORDANCE WITH THE SECTION 11B-602 AND ONE <br />ACCESSIBLE TO THOSE WHO HAVE DIFFICULTY BENDING OR STOOPING. <br />11.ALL POINT-OF-SALE MACHINES USED BY CUSTOMERS FOR THE PRIMARY <br />PURPOSE OF EXECUTING TRANSACTIONS BETWEEN THE BUSINESS ENTITY <br />AND THE CUSTOMER, SHALL COMPLY WITH SECTION 11B-220 . <br />GENERAL ACCESSIBILITY NOTES1 1/2" MIN. <br />AND MAX. <br />GRAB BAR NOTES: <br />1.BENDING STRESS IN GRAB BAR OR SEAT INDUCED BY THE MAXIMUM <br />BENDING MOMENT FROM THE APPLICATION OF 250 LBF SHALL BE LESS <br />THAN THE ALLOWABLE STRESS FOR THE MATERIAL OF THE GRAB BAR OR <br />SEAT. <br />2.SHEAR STRESS INDUCED IN A GRAB BAR OR SEAT BY THE APPLICATION OF <br />250 LBF SHALL BE LESS THAN THE ALLOWABLE SHEAR STRESS FOR THE <br />MATERIAL OF THE GRAB BAR OR SEAT. IF THE CONNECTION BETWEEN THE <br />GRAB BAR OR SEAT AND ITS MOUNTING BRACKET OR OTHER SUPPORT IS <br />CONSIDERED TO BE FULLY RESTRAINED, THEN DIRECT AND TORSIONAL <br />SHEAR STRESSES SHALL BE TOTALED FOR THE COMBINED SHEAR STRESS, <br />WHICH SHALL NOT EXCEED THE ALLOWABLE SHEAR STRESS. <br />3.SHEAR FORCE INDUCED IN A FASTENER OR MOUNTING DEVICE FROM THE <br />APPLICATION OF 250 LBF SHALL BE LESS THAN THE ALLOWABLE LATERAL <br />LOAD OF EITHER THE FASTENER OR MOUNTING DEVICE OR THE <br />SUPPORTING STRUCTURE, WHATEVER IS THE SMALLER ALLOWABLE LOAD. <br />4.TENSILE FORCE INDUCED IN A FASTENER BY A DIRECT TENSION FORCE OF <br />250 LBF PLUS THE MAXIMUM MOMENT FROM THE APPLICATION OF 250 <br />LBF SHALL BE LESS THAN THE ALLOWABLE WITHDRAWAL LOAD BETWEEN <br />THE FASTENER AND THE SUPPORTING STRUCTURE. <br />24 TYP. GRAB BAR DETAIL & NOTES <br />SCALE: 3" = 1'-0" <br />5 PEDESTRIAN PROTECTION <br />SCALE: 3/4" = 1'-0" <br />6" <br />MA <br />X <br />33 <br />" <br />FINISH FLOOR <br />FINISH FACE OF WALL <br />SIDEFRONT <br />18" <br />MIN. <br />32" <br />MIN. CLEAR <br />18 <br />" <br />MI <br />N <br />. <br />PLAN <br />FINISH FACE <br />OF WALL <br />2 TURNING SPACE <br />SCALE: 1/4" = 1'-0" <br />60" <br />60" <br />36 <br />" <br />60 <br />" <br />36"24 <br />" <br />12"12" <br />CIRCULAR T-SHAPED <br />3 CLEAR FLOOR SPACE <br />SCALE: 1/4" = 1'-0" <br />FORWARD PARALLEL <br />30" <br />48 <br />" <br />30 <br />" <br />48" <br />4 KNEE AND TOE CLEARANCE <br />SCALE: 1/4" = 1'-0" <br />TOE CLEARANCE <br />KNEE CLEARANCE <br />ELEVATION PLAN <br />PLANELEVATION <br />9" <br />MI <br />N <br />. <br />6" <br />MIN. <br />9" <br />MI <br />N <br />. <br />8" <br />MIN. <br />27 <br />" <br />MI <br />N <br />. <br />11" <br />MIN. <br />30 <br />" <br />MI <br />N <br />. <br />17"-25" <br />30 <br />" <br />MI <br />N <br />. <br />25" <br />MAX. <br />7 PROTRUDING OBJECTS <br />SCALE: 1/4" = 1'-0" <br />X <br />≥ 8 <br />0 <br />" <br />> <br />2 <br />7 <br />" <br />4" <br />MAX. <br />15 <br />" <br />MI <br />N <br />. <br />48 <br />" <br />MA <br />X <br />. <br />48 <br />" <br />MA <br />X <br />. <br />20" <br />MAX. <br />44 <br />" <br />MA <br />X <br />. <br />>20"-25" <br />15 <br />" <br />MI <br />N <br />. <br />48 <br />" <br />MA <br />X <br />. <br />46 <br />" <br />MA <br />X <br />. <br />>10"-24" <br />34 <br />" <br />MA <br />X <br />. <br />48 <br />" <br />MA <br />X <br />. <br />34 <br />" <br />MA <br />X <br />. <br />10" MAX. <br />6 REACH RANGES <br />SCALE: 1/4" = 1'-0" <br />FORWARD REACH <br />SIDE REACH <br />UNOBSTRUCTED OBSTRUCTED OBSTRUCTED <br />OBSTRUCTEDOBSTRUCTEDUNOBSTRUCTED <br />10" MAX. <br />15 CLEARANCES - MANUAL SWING DOORS <br />SCALE: 1/4" = 1'-0" <br />FRONT APPROACHPULL SIDE <br />FRONT APPROACHPUSH SIDE <br />HINGE APPROACHPULL SIDELATCH APPROACHPULL SIDE <br />HINGE APPROACHPUSH SIDELATCH APPROACHPUSH SIDE <br />HINGE APPROACHPULL SIDE <br />18" <br />MIN. <br />48 <br />" <br />MI <br />N <br />. <br />12" <br />MIN.* <br />42 <br />" <br />MI <br />N <br />. <br />22" <br />MIN. <br />HINGE APPROACHPUSH SIDE <br />48 <br />" <br />MI <br />N <br />. <br />22" <br />MIN.12" <br />MIN.42 <br />" <br />MI <br />N <br />. <br />24" <br />MIN. <br />42" <br />MIN. <br />36" <br />MIN. <br />24" <br />MIN. <br />* IF BOTH <br />CLOSER AND <br />LATCH ARE <br />PROVIDED <br />* 48" MIN. IF <br />CLOSER IS <br />PROVIDED <br />* 54" MIN. IF <br />CLOSER IS <br />PROVIDED <br />IF BOTH <br />CLOSER AND <br />LATCH ARE <br />PROVIDED <br />54 <br />" <br />MI <br />N <br />. <br />60 <br />" <br />MI <br />N <br />. <br />60 <br />" <br />MI <br />N <br />. <br />48 <br />" <br />MI <br />N <br />. <br />* <br />9 CLEARANCES - SLIDING & FOLDING DOORS <br />SCALE: 1/4" = 1'-0" <br />FRONT APPROACHPOCKET ORHINGE APPROACH STOP ORLATCH APPROACH <br />8 CLEARANCES - W/O DOORS <br />SCALE: 1/4" = 1'-0" <br />FRONT APPROACH SIDE APPROACH <br />20 CLEARANCES - RECESSED DOORS <br />SCALE: 1/4" = 1'-0" <br />PULL SIDE <br />PUSH SIDE <br />W/CLOSER & LATCH <br />18" <br />MIN. <br />X <br />> <br /> <br />8 <br />" <br />12" <br />MIN.* <br />60 <br />" <br />MI <br />N <br />. <br />48 <br />" <br />MI <br />N <br />. <br />X <br />> <br /> <br />8 <br />" <br />PUSH SIDE <br />48 <br />" <br />MI <br />N <br />. <br />X <br />> <br /> <br />8 <br />" <br />21 CLEAR WIDTH OF DOORWAYS <br />SCALE: 1/4" = 1'-0" <br />HINGED DOOR SLIDING DOOR <br />FOLDING DOOR DOORWAYS W/O DOORS <br />32" <br />MIN. <br />90°32" <br />MIN. <br />36" <br />MIN. <br />32" <br />MIN. <br />> <br />2 <br />4 <br />" <br />22" <br />MIN. <br />48 <br />" <br />MI <br />N <br />. <br />42 <br />" <br />MI <br />N <br />. <br />24" <br />MIN. <br />42 <br />" <br />MI <br />N <br />. <br />\A1;MIN. <br />26 DRINKING FOUNTAINS <br />SCALE: 1/4" = 1'-0" <br />SECTION <br />36 <br />" <br />MA <br />X <br />. <br />WH <br />E <br />E <br />L <br />C <br />H <br />A <br />I <br />R <br />AC <br />C <br />E <br />S <br />S <br />I <br />B <br />L <br />E <br />38 <br />" <br />- <br />4 <br />3 <br />" <br />ST <br />A <br />N <br />D <br />I <br />N <br />G <br />PE <br />R <br />S <br />O <br />N <br />15" <br />MIN. <br />5" <br />MAX. <br />15 <br />" <br />MI <br />N <br />. <br />5" <br />MA <br />X <br />. <br />PLAN <br />12 TOILET LOCATION <br />SCALE: 1/4" = 1'-0" <br />17"-18"17"-18" <br />AMBULATORY ACCESSIBLE TOILETSACCESSIBLE TOILETS <br />11 TOILET SEAT HEIGHT <br />SCALE: 1/4" = 1'-0" <br />17 <br />" <br />- <br />1 <br />9 <br />" <br />13 TOILET GRAB BARS <br />SCALE: 1/4" = 1'-0" <br />33 <br />" <br />- <br />3 <br />6 <br />" <br />39 <br />" <br />- <br />4 <br />1 <br />" <br />18 <br />" <br />MI <br />N <br />. <br />39"-41" <br />12" <br />MAX. <br />42" <br />MIN. <br />54" <br />MIN. <br />12" <br />MAX. <br />24" <br />MIN. <br />36" <br />MIN. <br />33 <br />" <br />- <br />3 <br />6 <br />" <br />SIDE WALL REAR WALL <br />14 TOILET COMPARTMENT <br />SCALE: 1/4" = 1'-0" <br />56 <br />" <br />MI <br />N <br />. <br />60" <br />MIN. <br />6" <br />MIN. <br />6" <br />MI <br />N <br />. <br />TOE CLEARANCE <br />25 URINALS <br />SCALE: 1/4" = 1'-0" <br />17 <br />" <br />MA <br />X <br />. <br />13 1/2" <br />MIN. <br />18 LAVATORIES <br />SCALE: 1/4" = 1'-0" <br />34 <br />" <br /> <br />M <br />A <br />X <br /> 2 <br />7 <br />" <br /> <br />M <br />I <br />N <br />. <br />9" <br />MI <br />N <br />11" <br />MIN. <br />9" <br />MIN. <br />8" <br />MIN. <br />WATER SUPPLY AND <br />DRAINPIPES UNDER <br />LAVATORIES AND SINKS <br />SHALL BE INSULATED OR <br />OTHERWISE CONFIGURED <br />TO PROTECT AGAINST <br />CONTACT. THERE SHALL BE <br />NO SHARP OR ABRASIVE <br />SURFACES UNDER <br />LAVATORIES OR SINKS. <br />SECTIONPLAN <br />30" <br />48 <br />" <br />SECTIONPLAN <br />CLEAR <br />FLOOR <br />SPACE <br />30" <br />MIN. <br />48 <br />" <br />MI <br />N <br />. <br />CLEAR <br />FLOOR <br />SPACE <br />17 <br />" <br />MI <br />N <br />19 <br />" <br />MA <br />X <br />. <br />16 ACCESSORY MOUNTING HEIGHTS <br />SCALE: 1/4" = 1'-0" <br />HANDDRYER <br />TOWELDISPENSER <br />BABYCHANGINGSTATION <br />HAND SANITIZER/SOAP DISPENSER <br />MIRROR <br />SANITARYWASTERECEPTACLE <br />TOILET SEATCOVERDISPENSER <br />28 <br /> <br />3 <br />/ <br />4 <br />" <br />44 <br />" <br />M <br />A <br />X <br />. <br />HA <br />N <br />D <br />L <br />E <br /> <br />A <br />R <br />E <br />A <br />HANDLES ARE <br />LOCATED ON <br />BOTH SIDE OF <br />THE UNIT <br />44 <br />" <br />38 <br /> <br />1 <br />/ <br />2 <br />" <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />OP <br />E <br />R <br />A <br />B <br />L <br />E <br />PA <br />R <br />T <br />S <br />40 <br />" <br />48 <br />" <br />8" <br />40 <br />" <br /> <br />M <br />A <br />X <br />. <br />BO <br />T <br />T <br />O <br />M <br /> <br />O <br />F <br />RE <br />F <br />L <br />E <br />C <br />T <br />I <br />V <br />E <br />SU <br />R <br />F <br />A <br />C <br />E <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />OP <br />E <br />R <br />A <br />B <br />L <br />E <br />PA <br />R <br />T <br />S <br />OTHER FIXTURES <br />NOT ALLOWED <br />WITHIN THIS AREA <br />18 <br />" <br />48 <br />" <br />48 <br />" <br />6' <br />- <br />8 <br />" <br />8" <br />TYPICAL LOCATION FOR LIGHT SWITCHES, DIMMERS, EGRESS BUTTONS, <br />THERMOSTATS, ETC. AND POWER AND TELEPHONE OUTLETS AT WALL OR COLUMN <br />44 <br />" <br />6' <br />- <br />8 <br />" <br />6" <br />42 <br />" <br />6' <br />- <br />8 <br />" <br />B <br />TYPICAL LOCATION FOR OUTLETS, SWITCHES <br />AND THERMOSTATS, ETC. AT CREDENZA OR <br />COUNTERTOP <br />TYPICAL LOCATION FOR ONE OR TWO <br />MOUNTED FIRE ALARM DEVICES / VISUAL <br />ALARM FEC <br />℄ <br />STROBE (AS <br />APPLICABLE) <br />THERMOSTAT <br />OR INTERCOM <br />LIGHT SWITCHES <br />DIMMERS, POWER <br />AND TELEPHONE <br />RECEPTACLE, ETC. <br />CREDENZA OR <br />COUNTER - REFER <br />TO ELEV./DETAILS <br />FINISH FLOOR <br />FIRE ALARM <br />(SPEAKER/ <br />STROBE OR <br />STROBE ONLY) <br />FIRE <br />EXTINGUISHER <br />FINISH FLOOR <br />DOOR FRAME EDGE <br />STROBE (AS APPLICABLE) <br />THERMOSTAT, INTERCOM OR SECOND ROW OF <br />RECEPTACLES CENTER TO CLUSTER (WHEN USING <br />DIMMERS, LOCATE THERMOSTAT AT OPPOSITE <br />SIDE OF DOOR) <br />LIGHT SWITCH, DIMMERS, EGRESS BUTTON, <br />INTERCOM BUTTON, CARD READER, ETC. <br />DOOR <br />LEVER, PULL <br />FINISH FLOOR <br />POWER AND TELEPHONE RECEPTACLE AND <br />CLUSTER VERTICALLY MOUNTED <br />℄ <br />℄℄ <br />44 <br />" <br />\A <br />1 <br />; <br />4 <br />4 <br />" <br />48" <br />AFF MIN. <br />60" <br />AFF MAX. <br />CENTERED <br />ON RAISED <br />CHARACTERS <br />18" <br />MIN. <br />22 TACTILE SIGN LOCATIONS <br />SCALE: 1/4" = 1'-0" <br />18 <br />" <br />MI <br />N <br />. <br />TACTILE SIGN NOTES: <br />1.WHERE A SIGN CONTAINING RAISED <br />CHARACTERS AND BRAILLE IS PROVIDED AT A <br />DOOR, THE SIGN SHALL BE ALONGSIDE THE <br />DOOR AT THE LATCH SIDE. <br />2.BRAILLE SHALL BE MOUNTED 48 INCHES <br />MINIMUM AND 60 INCHES MAXIMUM ABOVE <br />THE FLOOR, MEASURED TO THE BASELINE OF <br />THE BRAILLE CELLS AS PER SECTION 703.4.5. <br />3.SIGNS SHALL BE IN CONTRASTING COLOR AND <br />NON-GLARE. <br />THIS DRAWING IS A REPRESENTATIVE SUMMARY OF THE REQUIREMENTS OF THE ADA <br />STANDARDS THAT MAY BE APPLICABLE TO THE PROJECT. WHERE SPECIFIC DIMENSIONAL <br />INFORMATION AND CLEARANCES ARE NOT NOTED ON THE DRAWINGS, CONSTRUCT TO THE <br />CLEARANCES AND TOLERANCES SHOWN ON THIS SHEET. WHERE DRAWINGS SPECIFICALLY <br />INDICATE DIFFERENT OR CONFLICTING INFORMATION TO THE STANDARDS DEPICTED ON <br />THIS SHEET, CONSTRUCT USING THE MORE STRINGENT REQUIREMENT OR CONTACT THE <br />ARCHITECT FOR RESOLUTION <br />WOMEN <br />WOMEN <br />MEN <br />MEN <br />9"9" <br />56 <br />" <br /> <br />M <br />I <br />N <br />. <br />60 <br />' <br /> <br />M <br />A <br />X <br />. <br />56 <br />" <br /> <br />M <br />I <br />N <br />. <br />60 <br />" <br /> <br />M <br />A <br />X <br />. <br />5' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br />BA <br />S <br />E <br />L <br />I <br />N <br />E <br /> <br />T <br />A <br />C <br />T <br />I <br />L <br />E <br /> <br />A <br />R <br />E <br />A <br />12" <br />12"6" <br />MI <br />N <br />1'-6" <br />CLEAR FLOOR <br />SPACE <br />℄ <br />G.C. TO PROVIDE RESTROOM SIGN WITH RAISED AND <br />BRAILLE CHARACTERS AND PICTOGRAM SYMBOL AT <br />CORRIDOR SIDE OF TOILET ROOM DOOR AS PER STATE <br />AND LOCAL ACCESSIBILITY CODE. <br />℄ <br />1'-6" <br />CLEAR FLOOR <br />SPACE <br />5' <br />- <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br />BA <br />S <br />E <br />L <br />I <br />N <br />E <br /> <br />T <br />A <br />C <br />T <br />I <br />L <br />E <br /> <br />A <br />R <br />E <br />A <br />6" <br />MI <br />N <br />℄ <br />℄ <br />℄ <br />10 TYPICAL MOUNTING HEIGHTS <br />SCALE: 1/4" = 1'-0" <br />℄ <br />℄ <br />℄ <br />℄ <br />℄ <br />A <br />4" MIN. <br />C <br />48 <br />" <br /> <br />M <br />A <br />X <br />. <br />OP <br />E <br />R <br />A <br />B <br />L <br />E <br />PA <br />R <br />T <br />S <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />OP <br />E <br />R <br />A <br />B <br />L <br />E <br />PA <br />R <br />T <br />S <br />TACTILE CHARACTER HEIGHTABOVE FLOORCLEAR FLOOR SPACE FORTACTILE SIGNS AT DOORS <br />℄ <br />INTERNATIONAL SYMBOL OFACCESSIBILITY <br />17 TOILET PAPER DISPENSERS <br />SCALE: 1/4" = 1'-0" <br />PROTRUDING DISPENSERBELOW GRAB BAR <br />18 <br />" <br />MI <br />N <br />. <br />1 <br />1 <br />/ <br />2 <br />" <br />MI <br />N <br />. <br />42" <br />MAX. <br />24" <br />MIN. <br />\A1;MIN. <br />PROTRUDING DISPENSERABOVE GRAB BAR <br />24" <br />MIN. <br />36" <br />MAX. <br />12 <br />" <br />MI <br />N <br />. <br />48 <br />" <br />MA <br />X <br />. <br />\A1;MAX. <br />RECESSED DISPENSER <br />18 <br />" <br />MI <br />N <br />. <br />48 <br />" <br />MA <br />X <br />. <br />42" <br />MAX. <br />24" <br />MIN. <br />36" <br />MAX. <br />7"-9"7"-9" <br />24" <br />MIN. <br />℄℄ <br />1.6" - 2.4" <br />1. <br />6 <br />" <br /> <br />- <br /> <br />2 <br />. <br />4 <br />" <br />0.65" <br />MIN. <br />50% - 65% <br />BASE DIAMETER <br />0. <br />2 <br />"0.9" - 1.4" <br />GENERAL NOTES: <br />1.DETECTABLE WARNING SURFACES <br />SHALL HAVE TRUNCATED DOMES <br />COMPLYING WITH SECTION705.5. <br />2.DETECTABLE WARNING SURFACES <br />SHALL CONTRAST VISUALLY WITH <br />ADJACENT SURFACES, EITHER <br />LIGHT-ON-DARK OR DARK-ON-LIGHT. <br />3.TRUNCATED DOMES SHALL HAVE A <br />BASE DIAMETER OF 0.9 INCH <br />MINIMUM AND 1.4 INCH MAXIMUM, <br />AND A TOP DIAMETER OF 50% <br />MINIMUM AND 65% MAXIMUM OF <br />THE BASE DIAMETER. <br />4.TRUNCATED DOMES SHALL HAVE A <br />HEIGHT OF 0.2 INCH. <br />5.TRUNCATED DOMES TO BE <br />BOLT-DOWN. <br />19 TRUNCATED DOMES DETAIL <br />SCALE: 6" = 1'-0" <br />HEIGHT OF RAISEDCHARACTERS POSITION OF BRAILLE <br />3/ <br />8 <br />" <br />MI <br />N <br />. <br />3/ <br />8 <br />" <br />MI <br />N <br />. <br />5/ <br />8 <br />" <br /> <br />- <br /> <br />2 <br />" <br />GENERAL NOTES: <br />1.RAISED CHARACTERS SHALL BE 1/32" MINIMUM ABOVE THEIR BACKGROUND, SANS SERIF <br />STYLE AND UPPERCASE. <br />2.RAISED CHARACTERS SHALL BE 48 INCHES MINIMUM ABOVE THE FLOOR, MEASURED TO THE <br />BASELINE OF THE LOWEST RAISED CHARACTER AND 60 INCHES MAXIMUM ABOVE THE FLOOR, <br />MEASURED TO THE BASELINE OF THE HIGHEST RAISED CHARACTER. <br />3.BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH 703.3 AND 703.4. <br />4.BRAILLE SHALL BE POSITIONED BELOW THE CORRESPONDING TEXT. IF TEXT IS MULTI-LINED, <br />BRAILLE SHALL BE PLACED BELOW THE ENTIRE TEXT. (703.4.4) <br />5.BRAILLE SHALL BE 48 INCHES MINIMUM AND 60 INCHES MAXIMUM ABOVE THE FLOOR, <br />MEASURED TO THE BASELINE OF THE BRAILLE CELLS. <br />6.CHARACTERS OR BRAILLE SHALL NOT BE LOCATED IN THE PICTOGRAM FIELD. <br />23 TACTILE SIGN DETAILS <br />SCALE: 6" = 1'-0" <br />1 CHANGES IN LEVEL <br />SCALE: 1'-0" = 1'-0" <br />1/ <br />4 <br />" <br />(M <br />A <br />X <br />. <br />) <br />(A) VERTICAL <br />(B) BEVELED <br />1/ <br />2 <br />" <br />(M <br />A <br />X <br />. <br />) <br />1/ <br />4 <br />" <br />(M <br />A <br />X <br />. <br />) <br />1/ <br />4 <br />" <br />(M <br />A <br />X <br />. <br />) <br />1 <br />2 1/ <br />4 <br />" <br />(M <br />A <br />X <br />. <br />) <br />1 <br />2 <br />1801 EAST DYER RD. <br />SANTA ANA, CA 92705 <br />CONSULTANT <br />PROJECT <br />2022.0315.00 <br />54,016 SF <br />OWNER <br />PHONE:(404) 471-1634 <br />129 <br />08/01/2024 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br />2023 Q2 <br />ALL ARCHITECTURAL AND ENGINEERINGDRAWINGS ARE IN CONFIDENCE ANDDISSEMINATION MAY NOT BE MADE WITHOUTPRIOR WRITTEN CONSENT OF THE ARCHITECT.ALL COMMON LAW RIGHTS OF COPYRIGHT ANDOTHERWISE ARE HEREBY SPECIFICALLY RESERVED <br />2500 WINDY RIDGE PARKWAY, SE <br />ATLANTA, GA 30339 <br />ISSUE <br />DRAWN: <br />CHECKED: <br />SHEET <br />SEAL <br />AREA : <br />JOB NUMBER: <br />ISSUE DATE: <br />STORE NUMBER: <br />ST <br />O <br />R <br />E <br /> <br /># <br />1 <br />2 <br />9 <br />PROTOTYPE: <br />CITY APPROVAL STAMP <br />PERMIT SET 08/01/2024 <br />LICENSE: #C-39437 <br />EXP: 07/31/2025 <br />1 REVISION 1 12/12/2024 <br />1 REVISION 1 (RE-ISSUE)01/10/2025 <br />ACCESSIBILITY NOTES <br />G002 <br />KLS <br />AJB <br />1 <br />1 <br />1 <br />1 <br />1 <br />1801 E Dyer Rd <br />3/11/2025