My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1801 E Dyer Rd - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Dyer Rd
>
1801 E Dyer Rd
>
1801 E Dyer Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:07 PM
Creation date
6/6/2025 1:18:35 PM
Metadata
Fields
Template:
Plan
Permit Number
101120910
Full Address
1801 E Dyer Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
A.V. Schwan & Associates JOB TITLE F&D Santa Ana CPU Canopy <br />6000 E Thomas Rd <br />Scottsdale, AZ 85251 JOB NO.7202 SHEET NO. <br />602-265-4331 CALCULATED BY ATB DATE <br />CHECKED BY MK DATE <br /> Seismic Loads:CBC 2019 Strength Level Forces <br />Risk Category : II <br />Importance Factor (Ie) : 1.00 <br />Site Class : D - code default <br />Ss (0.2 sec) = 126.70 %g A site specific ground motion analysis is required for seismically <br />S1 (1.0 sec) = 45.40 %g isolated structures or with damping systems, see ASCE7 11.4.8 <br />Site specific ground motion analysis performed: <br />Fa = 1.200 Sms = 1.520 SDS =1.014 Design Category = D <br />Fv = 1.846 Sm1 = 0.838 SD1 =0.559 Design Category = D <br />Seismic Design Category =D <br /> Redundancy Coefficient ρ = 1.00 Code exception must be met for p to equal 1.0 <br />Number of Stories: 1 <br />Structure Type:All other building systems <br />Horizontal Struct Irregularities: No plan Irregularity <br />Vertical Structural Irregularities: No vertical Irregularity <br />Flexible Diaphragms: Yes <br />Building System: Cantilevered Column Systems detailed to conform to the requirements for: <br />Seismic resisting system: Steel ordinary cantilever column system <br />System Structural Height Limit: System not permitted for this seismic design category <br />Actual Structural Height (hn) = 18.0 ft <br />See ASCE7 Section 12.2.5 for exceptions and other system limitations <br />DESIGN COEFFICIENTS AND FACTORS <br />Response Modification Coefficient (R) = 1.25 <br /> Over-Strength Factor (Ωo) =1.25 <br />Deflection Amplification Factor (Cd) = 1.25 <br />SDS =1.000 (Sds modified for Cs & Ev calculation since <br />SD1 =0.559 meets ASCE 7 section 12.8.1.3) <br />Seismic Load Effect (E) = Eh +/-Ev = ρ QE +/- 0.2SDS D = Qe +/-0.200D QE = horizontal seismic force <br />Special Seismic Load Effect (Em) =Emh +/- Ev = Ωo QE +/- 0.2SDS D = 1.25Qe +/-0.203D D = dead load <br />PERMITTED ANALYTICAL PROCEDURES <br />Simplified Analysis - Use Equivalent Lateral Force Analysis <br />Equivalent Lateral-Force Analysis - Permitted <br />Building period coef. (CT) =0.020 Cu = 1.40 <br />Approx fundamental period (Ta) =CThn <br />x = 0.175 Tmax = CuTa = 0.245 sec <br />User calculated fundamental period = T = 0.175 sec <br />Long Period Transition Period (TL) =ASCE7 map =8 sec <br />Seismic response coef. (Cs) =SdsI/R =0.800 ASCE7 11.4.8 exception 2 equations used <br />but not less than Cs = 0.044SdsI = 0.044 <br />USE Cs = 0.800 <br />Design Base Shear V =0.800W <br />Model & Seismic Response Analysis - Permitted (see code for procedure) <br />ALLOWABLE STORY DRIFT <br />Structure Type: All other structures <br />Allowable story drift Δa = 0.020hsx where hsx is the story height below level x <br />sec x= 0.75 <br />10 of 42 <br />1801 E Dyer Rd <br />3/11/2025
The URL can be used to link to this page
Your browser does not support the video tag.