My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1801 E Dyer Rd - Plan
PBA
>
Building
>
ProjectDox
>
D
>
Dyer Rd
>
1801 E Dyer Rd
>
1801 E Dyer Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:07 PM
Creation date
6/6/2025 1:18:35 PM
Metadata
Fields
Template:
Plan
Permit Number
101120910
Full Address
1801 E Dyer Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
G.C. TO INSTALL NEW WATER CLOSET TANK - REFER TO SHEET P101 FOR MORE <br />INFORMATION. <br />G.C. TO REINSTALL EXISTING HORIZONTAL 42" GRAB BAR PER DETAIL 13/G002. FILL <br />HOLES WITH GROUT/CAULK TO MATCH EXISTING WALL FINISH. <br />G.C. TO REINSTALL EXISTING VERTICAL 18" GRAB BAR PER DETAIL 13/G002. FILL <br />HOLES WITH GROUT/CAULK TO MATCH EXISTING WALL FINISH. <br />G.C. TO REINSTALL EXISTING HORIZONTAL 36" GRAB BAR PER DETAIL 13/G002. G.C. <br />TO INSTALL A 2X BLOCK OF FIRE RETARDANT TREATED WOOD TO COMPENSATE FOR <br />THE JOG IN THE WALL. SAND AND PAINT BLOCK OF WOOD TO MATCH WALL TILE. <br />FILL HOLES WITH GROUT/CAULK TO MATCH EXISTING WALL FINISH. <br />G.C. TO REINSTALL EXISTING HORIZONTAL 36" GRAB BAR PER DETAIL 13/G002. FILL <br />HOLES WITH GROUT/CAULK TO MATCH EXISTING WALL FINISH. <br />G.C. TO INSTALL NEW HAND TOWEL DISPENSER (TYPE J) PER DETAIL 17/G002 AND <br />ACCESSORIES SCHEDULE ON SHEET A005. <br />G.C. TO REINSTALL EXISTING TOILET SEAT COVER DISPENSER. FILL HOLES WITH <br />GROUT/CAULK TO MATCH EXISTING WALL FINISH. <br />G.C. TO INSTALL NEW COUNTERTOP AND LAVATORIES. REFER TO SHEETS A005 AND <br />P101 FOR FURTHER INFORMATION. <br />G.C. TO REINSTALL EXISTING FEMININE SANITARY NAPKIN WASTE CONTAINER. <br />INSTALL AS DIMENSIONED THIS SHEET AND PER DETAIL 16/G002. <br />G.C. TO REINSTALL EXISTING SOAP DISPENSER PER DETAIL 16/002. <br />G.C. TO INSTALL NEW HI-LO DRINKING FOUNTAINS WITH CANE APRON ON THE HIGH <br />UNIT. INSTALL PER DETAIL 26/G002 AND REFER TO SHEET P101 FOR FURTHER <br />INFORMATION. <br />G.C. TO INSTALL PLYWOOD BEHIND THE DRINKING FOUNTAIN TO THE FLOOR. PAINT <br />PLYWOOD TO MATCH ADJACENT WALL. G.C. TO EXPLORE WHETHER WALL CAN BE <br />REPAIRED BEHIND EXISTING PLYWOOD IN LIEU OF INSTALLING NEW PLYWOOD TO <br />THE FLOOR. <br />G.C. TO INSTALL NEW TOILET PARTITION AND DOOR TO MATCH EXISTING. REUSE <br />EXISTING COMPONENTS WHERE POSSIBLE. INSTALL A CLOSER ON THE ACCESSIBLE <br />STALL DOOR. <br />G.C. TO INSTALL NEW BABY CHANGING STATION (TYPE L) PER DETAIL 16/G002, <br />DETAIL 8/A005, AND ACCESSORIES SCHEDULE ON SHEET A005. <br />G.C. TO REINSTALL TOILET PAPER DISPENSER PER DETAIL 17/G002. <br />G.C. TO INSTALL NEW SINK PER DETAIL 1/A005 AND SHEET P101. <br />INSTALL NEW BASE CABINETS WITH FINISH AND STYLE TO MATCH EXISTING UPPER <br />CABINETS. <br />INSTALL NEW COUNTERTOP (SS-1) PER FINISH SCHEDULE ON SHEET A005. <br />G.C. TO RE-INSTALL NON-ADA STALL DOOR HARDWARE ON NEW PARTITION <br />SECTION. <br />G.C. TO ENSURE 30" X 48" CLEAR FLOOR SPACE AREA IS CENTERED UNDER <br />LAVATORY. <br />G.C. TO INSTALL NEW COAT HOOK TO MATCH EXISTING ON ACCESSIBLE STALL DOOR <br />AT 3'-10" A.F.F. TO THE CENTER OF THE HOOK. <br />G.C. TO ADJUST DOOR CLOSER TO ENSURE THAT FROM AN OPEN POSITION OF 90 <br />DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO A POSITION OF 12 DEGREES <br />FROM THE LATCH IS 5 SECONDS MINIMUM. <br />G.C. TO ADJUST DOOR CLOSER TO ENSURE THE PUSHING AND PULLING FORCE IS 5 <br />POUNDS MAXIMUM. <br />G.C. TO ENSURE 5'-7" DIAMETER TURNING SPACE CLEARANCE - SEE G002 FOR MORE <br />INFORMATION <br />1 1/2" DIA BOBRICK 819298 DRINKING FOUNTAIN GRAB BAR <br />1234 <br />56789101112 <br />13141516171819202122232425 <br />GENERAL NOTES <br />KEYNOTES <br />A.PROVIDE ALL NECESSARY F.R.T. WOOD BLOCKING OR METAL STUD BLOCKING FOR ALL <br />WALL SUPPORTED DEVICES, I.E. ACCESSORIES, PANELS, EQUIPMENT, ETC. PER THE <br />DEVICE MANUFACTURER'S RECOMMENDATIONS. <br />B.ALL FLOOR PLANS ARE DIMENSIONS FROM FACE OF GYP. BD TO FACE OF GYP. BD. <br />U.N.O. <br />C.ANY ITEM LABELED EXISTING TO REMAIN IS TO BE INSPECTED BY G.C. AND PATCHED <br />AND REPAIRED TO LIKE NEW CONDITION COORDINATED WITH F&D CPM. PREPARE TO <br />RECEIVE NEW FINISHES. <br />DRAWING LEGEND <br />XX XX <br />XX <br />XX <br />ROOM NAME <br />XXX <br />MULTIPLE ELEVATION CALLOUT <br />SINGLE ELEVATION CALLOUT <br />ROOM IDENTIFIER <br />COLUMN CENTER LINE <br />COLUMN CENTER LINE ON FACE <br />OF WALL <br />REVISION IDENTIFIER <br />KEYNOTE IDENTIFIER <br />NEW DOOR <br />EXISTING DOOR <br />X <br />X <br />X <br />14 <br />NORTH <br />1 ENLARGED FIRST FLOOR PLAN <br />SCALE: 1/2" = 1'-0" <br />2 ENLARGED SECOND FLOOR PLAN PLAN <br />SCALE: 1/2" = 1'-0" <br />1 <br />A005 <br />3 <br />A005 <br />2 <br />A005 <br />4 <br />5 <br />1 <br />4 4 <br />27 3 15 2 7315 <br />2 <br />2 <br />1537 <br />13 <br />15 <br />7 <br />3 <br />15 <br />9 <br />15 <br />9 <br />9 <br />5 <br />6 6 <br />1'-3"1'-6" <br />6 <br />3' <br />- <br />0 <br />" <br />6' <br />- <br />0 <br />" <br />3' <br />- <br />8 <br />" <br />6 <br />1'-0" <br />8 <br />8 <br />8 <br />8 <br />10 <br />10 <br />10 <br />11 <br />11 <br />12 <br />13 <br />14 <br />14 <br />6 <br />WOMEN'S <br />RESTROOM <br />100 <br />MEN'S <br />RESTROOM <br />101 <br />MEN'S <br />RESTROOM <br />201 <br />WOMEN'S <br />RESTROOM <br />200 <br />2 3 <br />A <br />2 3 <br />A <br />3 <br />16 <br />17 <br />18 <br />6' <br />- <br />2 <br />" <br />1' <br />- <br />3 <br />" <br />3' <br />- <br />1 <br />" <br />7' <br />- <br />9 <br /> <br />3 <br />/ <br />4 <br />" <br />2' <br />- <br />1 <br />0 <br /> <br />1 <br />/ <br />2 <br />" <br />4' <br />- <br />9 <br /> <br />1 <br />/ <br />2 <br />" <br />3' <br />- <br />1 <br />0 <br /> <br />1 <br />/ <br />4 <br />" <br />6'-10 1/4" <br />1'-7"3'-2" <br />8'-3 1/4" <br />3'-6 3/4"3'-1" <br />19 <br />19 <br />20 <br />20 <br />20 <br />20 <br />21 <br />21 <br />22 <br />23 <br />2223 <br />2223 <br />22 <br />23 <br />2'-6" <br />4' <br />- <br />0 <br />" <br />4'-0" <br />4'-0" <br />2' <br />- <br />6 <br />" <br />4'-0"13 <br />4' <br />- <br />0 <br />" <br />4'-6" <br />5' <br />- <br />0 <br />" <br />5'-0" <br />13 <br />4' <br />- <br />1 <br />1 <br />" <br />4' <br />- <br />0 <br />" <br />4'-0" <br />2'-6" <br />4'-0" <br />2' <br />- <br />6 <br />" <br />4' <br />- <br />0 <br />" <br />2'-6" <br />4' <br />- <br />0 <br />" <br />4'-0" <br />4' <br />- <br />0 <br />" <br />4'-6" <br />5' <br />- <br />0 <br />" <br />4'-6" <br />4'-0" <br />4' <br />- <br />0 <br />" <br />4'-0" <br />2' <br />- <br />6 <br />" <br />4'-0" <br />2' <br />- <br />6 <br />" <br />4'-6" <br />5' <br />- <br />0 <br />" <br />4'-6" <br />5' <br />- <br />0 <br />" <br />4' <br />- <br />4 <br />" <br />4'-0" <br />4' <br />- <br />0 <br />" <br />4'-0" <br />2'-6" <br />4' <br />- <br />0 <br />" <br />4'-0" <br />2' <br />- <br />6 <br />" <br />4' <br />- <br />0 <br />" <br />4'-0" <br />4'-6" <br />5' <br />- <br />0 <br />" <br />5' <br />- <br />0 <br />" <br />4'-6" <br />4' <br />- <br />0 <br />" <br />4'-0" <br />5' <br />- <br />0 <br />" <br />4'-6" <br />℄ <br />℄ <br />℄ <br />℄ <br />℄℄ <br />℄℄ <br />24 <br />24 <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />5" <br /> <br />M <br />A <br />X <br />. <br />15 <br />" <br /> <br />M <br />I <br />N <br />. <br />5" <br /> <br />M <br />A <br />X <br />. <br />2525 <br />2525 <br />5'-0" <br />5'-0" <br />5'-0"5'-0" <br />5'-0" <br />7' <br />- <br />2 <br />" <br />5'-3 1/2" <br />7'-2 3/8" <br />5' <br />- <br />0 <br />" <br />5'-0"5'-0" <br />℄ <br />1801 EAST DYER RD. <br />SANTA ANA, CA 92705 <br />CONSULTANT <br />PROJECT <br />2022.0315.00 <br />54,016 SF <br />OWNER <br />PHONE:(404) 471-1634 <br />129 <br />08/01/2024 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br />2023 Q2 <br />ALL ARCHITECTURAL AND ENGINEERINGDRAWINGS ARE IN CONFIDENCE ANDDISSEMINATION MAY NOT BE MADE WITHOUTPRIOR WRITTEN CONSENT OF THE ARCHITECT.ALL COMMON LAW RIGHTS OF COPYRIGHT ANDOTHERWISE ARE HEREBY SPECIFICALLY RESERVED <br />2500 WINDY RIDGE PARKWAY, SE <br />ATLANTA, GA 30339 <br />ISSUE <br />DRAWN: <br />CHECKED: <br />SHEET <br />SEAL <br />AREA : <br />JOB NUMBER: <br />ISSUE DATE: <br />STORE NUMBER: <br />ST <br />O <br />R <br />E <br /> <br /># <br />1 <br />2 <br />9 <br />PROTOTYPE: <br />CITY APPROVAL STAMP <br />PERMIT SET 08/01/2024 <br />LICENSE: #C-39437 <br />EXP: 07/31/2025 <br />1 REVISION 1 12/12/2024 <br />1 REVISION 1 (RE-ISSUE)01/10/2025 <br />ENLARGED FLOOR <br />PLANS <br />A004 <br />MBKC <br />AJB <br />1 <br />1 <br />1 <br />1 1 <br />1 <br />1 <br />1 <br />1 <br />11 <br />1801 E Dyer Rd <br />3/11/2025
The URL can be used to link to this page
Your browser does not support the video tag.