My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1700 E St Andrew - Plan
PBA
>
Building
>
ProjectDox
>
S
>
St Andrew Pl
>
1700 E St Andrew Pl
>
1700 E St Andrew - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:19:16 PM
Creation date
6/6/2025 1:18:35 PM
Metadata
Fields
Template:
Plan
Permit Number
30147489
101120027
101120028
Full Address
1700 E St Andrew Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
86
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
GFI <br />FE <br />FIRE ALARMPANEL <br />SFEC <br />SFEC <br />SFEC SFEC <br />SFEC <br />SFEC <br />SFEC <br />SFEC <br />SFEC <br />SFEC <br />SFECSFEC <br />SFEC <br />SFEC <br />SFEC <br />SFEC <br />SFE <br />C SFEC <br />SFEC <br />SFEC <br />+8'-7"+8'-7" <br />FIRST FLOOR - ENLARGED <br />RESTROOM PLANS <br />A-0.7a <br />AS NOTED <br />PROJECT: <br />DATE: <br />DRAWN: <br />SCALE: <br />PROJECT NO: <br />REVIEWED: <br />SHEET NO: <br />SHEET TITLE: <br />STAMP AND SIGNATURE: <br />CONSULTANTS: <br />DATE DESCRIPTION DELTA <br />DRAWINGS ISSUE <br />06/21/2024 ISSUE FOR PLAN CHECK <br />6083 Bristol Parkway <br />Culver City, CA 90230 <br />515 South Flower St., Suite 1200 <br />Los Angeles, CA 90071 <br />18600 MacArthur Blvd., Suite 100 <br />Irvine, CA 92612 <br />485C US Route 1 South, Suite 105 <br />Iselin, NJ 08830 <br />www.saaia.com <br />T 310.553.3252 <br />T 213.929.1400 <br />T 949.724.8958 <br />San Francisco, CA 94105 <br />T 415.390.6793 <br />T 848.200.1200 <br />New York, NY 10017 <br />T 917.512.6688 <br />575 Market St., Suite 502 <br />711 3rd Ave., 6th Floor <br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL <br />REMAIN IT'S PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE, <br />OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES. <br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED <br />09/06/2024 <br />D.S. <br />K.L./M.P. <br />635330 <br />1700 E ST ANDREW <br />ACCESSIBLITY <br />UPGRADES <br />1700 E ST ANDREW PL <br />SANTA ANA, CA 92705 <br />C U L V E R C I T Y , C A •I R V I N E , C A • L O S A N G E L E S , C A <br />S A N F R A N C I S C O , C A • I S E L I N , N J • N E W Y O R K , N Y <br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN <br />RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS <br />ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT <br />ANY TIME PER THEIR DISCRETION. IN USING RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT ACKNOWLEDGES THAT IT WAS BASED ON <br />THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS <br />AND MATERIALS BY OTHERS. SAA'S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT'S STRATEGIES AND DO NOT CONSTITUTE AS <br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR <br />COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT <br />BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES. <br />08/20/2024 ISSUE FOR PLAN CHECK - OCFA <br />09/06/2024 PLAN CHECK COMMENTS 01 1 <br />B ENLARGED CONSTRUCTION PLAN <br />SCALE: 1/4" = 1'-0" <br />CONSTRUCTION KEYNOTES <br />LEGEND <br />DEMOLITION KEYNOTES <br />EXISTING PARTITION TO REMAIN. PATCH AND REPAIR AS REQUIRED.1.1 <br />1SCALE: <br />1/4"=1'-0" <br />N <br />A ENLARGED DEMOLITION PLAN <br />SCALE: 1/4" = 1'-0" <br />KEY PLAN <br />AREA OF WORK <br />YRC MEN'S <br />RESTROOM <br />131 <br />YRC WOMEN'S <br />RESTROOM <br />132 <br />FIRST FLOOR YRC RESTROOMS - ENLARGED PLANS <br />D ENLARGED REFLECTED CEILING PLAN <br />SCALE: 1/4" = 1'-0"C ENLARGED FINISH PLAN <br />SCALE: 1/4" = 1'-0" <br />YRC MEN'S <br />RESTROOM <br />131 <br />YRC WOMEN'S <br />RESTROOM <br />132 <br />YRC MEN'S <br />RESTROOM <br />131 <br />YRC WOMEN'S <br />RESTROOM <br />132 <br />REFLECTED CEILING PLAN KEYNOTES <br />FINISH PLAN KEYNOTES <br />EXISTING WALL TO REMAIN. <br />EXISTING DOOR TO REMAIN. CLEAN, REPAIR AND REPAINT DOOR PER FINISH PLANS <br />AND DOOR SCHEDULE. <br />EXISTING PARTITION TO BE DEMOLISHED AND REMOVED FROM SITE. <br />AREA NOT IN CONTRACT (N.I.C.) <br />EXISTING DOOR TO REMAIN. CLEAN AND REPAIR AS REQUIRED.1.2 <br />EXISTING FINISHES TO REMAIN, PROTECT IN PLACE. CLEAN AND RE-GROUT ALL FLOOR AND WALL TILES. PATCH <br />AND REPAIR DAMAGED TILES AND FINISHES AFFECTED BY DEMOLITION. MATCH EXISTING FINISHES.1.6 <br />SKIM COAT WALLS AS REQUIRED TO PREPARE FOR NEW WALL PAINT, SEE FINISH SCHEDULE.1.7 <br />REMOVE EXISTING RESTROOM ACCESSORIES AND STALL PARTITION. SAVE ACCESSORIES IN GOOD CONDITION FOR <br />RE-USE OR RETURN TO BUILDING STORAGE AS DIRECTED BY BUILDING OWNER.1.8 <br />EXISTING RESTROOM ACCESSORY TO REMAIN. CLEAN AND REPAIR AS REQUIRED. PROVIDE NEW IF EXISTING <br />FIXTURE IS IN BAD CONDITION. SEE FIXTURE SCHEDULE ON SHEET A-0.7.1.3 <br />REMOVE EXISTING PLUMBING FIXTURE, SAVE FOR RELOCATION. CLEAN AND REPAIR PLUMBING FIXTURE AS <br />REQUIRED. RE-USE AND RE-ROUTE PLUMBING LINE TO NEW LOCATION OF FIXTURE. SEE CONSTRUCTION PLAN.1.9 <br />NEW RESTROOM PARTITION PER FIXTURE SCHEDULE ON SHEET A-0.7. PROVIDE NEW PARTITION FOR ACCESSIBLE <br />STALLS AND STALLS AFFECTED BY SCOPE.2.1 <br />RELOCATED PLUMBING FIXTURE IN ACCESSIBLE STALL. MOUNTING HEIGHT ON WALL TO COMPLY WITH <br />11B-604.2. RE-ROUTE AND CONNECT TO EXISTING PLUMBING LINE. PATCH AND REPAIR WALL AND FLOOR <br />DAMAGED BY FIXTURE RELOCATION. SEE PLUMBING DRAWINGS. <br />2.2 <br />NEW SOLID SURFACE COUNTERTOP WITH SINK SKIRT. SEE FINISH SCHEDULE. SEE DETAIL 9/A-30.0.2.4 <br />REMOVE EXISTING SINK, FIXTURES, AND COUNTER. RE-USE AND RELOCATE EXISTING PLUMBING LINES FOR NEW <br />FIXTURE. SEE CONSTRUCTION PLAN.1.10 <br />NEW UNDER COUNTER MOUNTED SINK AND ACCESSORIES AS SPECIFIED ON PLUMBING FIXTURE SCHEDULE ON <br />SHEET A-0.7.2.5 <br />EXISTING GYP. BD. HARD LID CEILING TO REMAIN. CLEAN, PATCH AND REPAIR AS REQUIRED. PAINT, SEE FINISH <br />PLAN.4.1 <br />EXISTING LIGHT FIXTURES TO REMAIN, REPLACE BULBS THROUGHOUT. CLEAN AND REPAIR AS REQUIRED. RETURN <br />AND BULBS IN GOOD CONDITION TO BUILDING STORAGE OR AS DIRECTED BY OWNER.4.2 <br />CLEAN, PATCH AND REPAIR ALL FINISHES AFFECTED BY SCOPE. MATCH EXISTING FINISHES.5.1 <br />FINISH LEGEND <br />WALL FINISH <br />TYPE OF FINISH <br />FINISH NUMBER <br />SPECIAL FINISH <br />TYPE OF FINISH <br />FINISH NUMBER <br />XX <br />XX <br />XX <br />XX <br />PATTERN DIRECTION <br />FLOOR BASE <br />TYPE OF FINISH <br />FINISH NUMBER <br />FLOOR FINISH <br />TYPE OF FINISH <br />FINISH NUMBER <br />XX <br />XX <br />XX <br />XX <br />FLOOR TRANSITION <br />FINISH SCHEDULE <br />:FIELD PAINT <br />:REFER TO PLANS <br />:DUNN EDWARDS <br />:DEW365 PRECIOUS PEARLS <br />:EGGSHELL AT WALL, SEMI GLOSS AT RESTROOMS, FLAT AT CEILING <br />:2 COATS MINIMUM <br />ITEM <br />LOCATION <br />MANUFACTURER <br />COLOR <br />FINISH <br />INSTALLATION <br />P <br />1 <br />:SOLID SURFACE <br />:REFER TO PLANS <br />:VADARA QUARTZ <br />:AURORA FROST - V741 <br />ITEM <br />LOCATION <br />MANUFACTURER <br />COLOR <br />SS <br />1 <br />P <br />1 <br />P <br />1 <br />SS <br />1 <br />SS <br />1 <br />1.8 <br />TYP. <br />1.1 <br />TYP.1.1 <br />TYP. <br />1.2 1.2 <br />1.3 1.3 <br />1.6 <br />TYP. <br />1.7 <br />1.9 <br />1.5 <br />1.10 <br />2.4 <br />2.5 <br />2.2 <br />4.1 <br />TYP. <br />4.2 4.2 <br />4.2 4.2 <br />4.1 <br />TYP. <br />4.2 <br />4.2 <br />4.2 <br />4.2 <br />ALTERNATE NOTES <br />PROVIDE ALTERNATE PRICING TO PROVIDE EPOXY COATING OVER EXISTING FLOOR TILE. <br />SPECIFICATION: TBDA <br />PROVIDE ALTERNATE FOR REPLACING EXISTING EXISTING FLUSH VALVES WITH NEW AUTOMATIC FLUSH VALVES <br />AT PLUMBING FIXTURES AND REPLACING EXISTING SINK FAUCETS WITH NEW AUTOMATIC FAUCETS AND <br />PROVIDING NEW SOAP DISPENSERS AT SINKS. SEE SPECIFICATION ON FIXTURE SCHEDULE ON SHEET A-0.7. <br />B <br />NEW RESTROOM ACCESSORIES AS SPECIFIED ON PLUMBING FIXTURE SCHEDULE ON SHEET A-0.7. RE-USE <br />EXISTING ACCESSORIES IN GOOD CONDITION, PROVIDE NEW FOR ACCESSORIES IN BAD CONDITION.2.3 <br />REPLACE ANY WALL AND FLOOR TILE AFFECTED BY SCOPE. CLEAN AND RE-GROUT ALL FLOOR AND WALL TILE. <br />MATCH EXISTING FINISHES.5.2 <br />5.1 5.25.1 5.2 <br />2.4 <br />2.5 <br />2.1 <br />2'-0" <br />±5 <br />' <br />- <br />5 <br />" <br />V. <br />I <br />. <br />F <br />. <br />±5 <br />' <br />- <br />4 <br />" <br />V. <br />I <br />. <br />F <br />. <br />2'-0" <br />EXISTING STALL PARTITIONS TO REMAIN. CLEAN AND REPAIR AREAS DAMAGED BY DEMOLITION.1.4 <br />EXISTING PLUMBING FIXTURE TO REMAIN, PROTECT IN PLACE. CLEAN AND REPAIR AS REQUIRED.1.5 <br />1.4 <br />TYP. <br />1.9 <br />1.5 <br />1.6 <br />TYP. <br />1.7 <br />1.10 <br />1.4 <br />TYP. <br />1.5 <br />1.5 <br />1.8 <br />TYP. <br />2.2 <br />2.3 <br />2.3 <br />2.3 <br />TYP. <br />TYP. <br />TYP. <br />2.3 <br />TYP. <br />B B <br />B <br />B <br />B <br />B <br />B B <br />2.1 <br />A A <br />NELSON <br />ALGAZE <br />No. C-21090 <br />REN. 03/31/2025 <br />L <br />CENSE ARC <br />EC <br />SAE O CAL ORNA <br />1700 E St Andrew Pl - <br />ADA Upgrades12/2/2024
The URL can be used to link to this page
Your browser does not support the video tag.