GFI
<br />K
<br />+85"
<br />+63" GFI
<br />+44"
<br />GFI
<br />+63" GFI
<br />+44" GFI
<br />K
<br />+8'-4"
<br />+8'-4"
<br />+8'-4"
<br />FIRST FLOOR - ENLARGED
<br />RESTROOM PLANS
<br />A-0.7c
<br />AS NOTED
<br />PROJECT:
<br />DATE:
<br />DRAWN:
<br />SCALE:
<br />PROJECT NO:
<br />REVIEWED:
<br />SHEET NO:
<br />SHEET TITLE:
<br />STAMP AND SIGNATURE:
<br />CONSULTANTS:
<br />DATE DESCRIPTION DELTA
<br />DRAWINGS ISSUE
<br />06/21/2024 ISSUE FOR PLAN CHECK
<br />6083 Bristol Parkway
<br />Culver City, CA 90230
<br />515 South Flower St., Suite 1200
<br />Los Angeles, CA 90071
<br />18600 MacArthur Blvd., Suite 100
<br />Irvine, CA 92612
<br />485C US Route 1 South, Suite 105
<br />Iselin, NJ 08830
<br />www.saaia.com
<br />T 310.553.3252
<br />T 213.929.1400
<br />T 949.724.8958
<br />San Francisco, CA 94105
<br />T 415.390.6793
<br />T 848.200.1200
<br />New York, NY 10017
<br />T 917.512.6688
<br />575 Market St., Suite 502
<br />711 3rd Ave., 6th Floor
<br />OWNERSHIP AND USE OF DOCUMENTS ALL DRAWINGS, SPECIFICATIONS AND COPIES THEREOF FURNISHED BY SAA INTERIORS ARE AND SHALL
<br />REMAIN IT'S PROPERTY. THEY ARE TO BE USED ONLY WITH RESPECT TO THIS PROJECT. FEDERAL LAW PROHIBITS THE REPRODUCTION, DISPLAY, SALE,
<br />OR OTHER DISPOSITION OF THIS DOCUMENT WITHOUT THE EXPRESS WRITTEN CONSENT OF SHLEMMER ALGAZE ASSOCIATES.
<br />COPYRIGHT © 2015 SHLEMMER ALGAZE ASSOCIATES ALL RIGHTS RESERVED
<br />09/06/2024
<br />D.S.
<br />K.L./M.P.
<br />635330
<br />1700 E ST ANDREW
<br />ACCESSIBLITY
<br />UPGRADES
<br />1700 E ST ANDREW PL
<br />SANTA ANA, CA 92705
<br />C U L V E R C I T Y , C A •I R V I N E , C A • L O S A N G E L E S , C A
<br />S A N F R A N C I S C O , C A • I S E L I N , N J • N E W Y O R K , N Y
<br />IF DRAWINGS AND MATERIALS DEVELOPED AND PROVIDED BY SAA INTERIORS + ARCHITECTURE AT THE TIME OF AND RELATING TO COVID-19 CONTAIN
<br />RECOMMENDATIONS FROM THE CENTER FOR DISEASE CONTROL AND PREVENTION (CDC) AND THE WORLD HEALTH ORGANIZATION (WHO), SUCH RECOMMENDATIONS
<br />ARE ONLY VALID AS OF THE DATE THE DRAWINGS AND MATERIALS ARE PRODUCED. THE CDC AND/OR WHO MAY UPDATE OR MODIFY THEIR RECOMMENDATIONS AT
<br />ANY TIME PER THEIR DISCRETION. IN USING RECOMMENDATIONS FROM THESE DRAWINGS AND MATERIALS, THE RECIPIENT ACKNOWLEDGES THAT IT WAS BASED ON
<br />THEIR OWN DECISION AND TAKE FULL RESPONSIBILITY AND LIABILITY. THE INTENDED RECIPIENT INDEMNIFIES AND DEFENDS SAA FOR ANY USE OF THESE DRAWINGS
<br />AND MATERIALS BY OTHERS. SAA'S SERVICES ARE INTENDED TO ONLY BE OF ASSISTANCE AND GUIDANCE FOR OUR CLIENT'S STRATEGIES AND DO NOT CONSTITUTE AS
<br />REQUIREMENTS OR ANY FORM OF HEALTH, ILLNESS OR DISEASE ADVICE. SAA MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE ACCURACY OR
<br />COMPLETENESS OF THE DRAWINGS AND MATERIALS. ANY RECOMMENDATIONS OR USE OF ANY CDC OR WHO INFORMATION DOES NOT CONSTITUTE ENDORSEMENT
<br />BY THE U.S. GOVERNMENT, DEPARTMENT OF HEALTH AND HUMAN SERVICES OR THE CDC AND WHO NOR ITS AFFILIATES.
<br />08/20/2024 ISSUE FOR PLAN CHECK - OCFA
<br />09/06/2024 PLAN CHECK COMMENTS 01 1
<br />B ENLARGED CONSTRUCTION PLAN
<br />SCALE: 1/4" = 1'-0"
<br />1SCALE:
<br />AS NOTED
<br />N
<br />FIRST FLOOR YRC RESTROOMS - ENLARGED PLANS
<br />C ENLARGED FINISH PLAN
<br />SCALE: 1/4" = 1'-0"D ENLARGED REFLECTED CEILING PLAN
<br />SCALE: 1/4" = 1'-0"
<br />MEN'S SHOWER
<br />& RESTROOM
<br />180
<br />CONSTRUCTION KEYNOTES
<br />LEGEND
<br />DEMOLITION KEYNOTES
<br />KEY PLAN
<br />AREA OF WORK
<br />REFLECTED CEILING PLAN KEYNOTES
<br />FINISH PLAN KEYNOTES
<br />EXISTING WALL TO REMAIN.
<br />EXISTING DOOR TO REMAIN. CLEAN, REPAIR AND REPAINT DOOR PER FINISH PLANS
<br />AND DOOR SCHEDULE.
<br />EXISTING PARTITION TO BE DEMOLISHED AND REMOVED FROM SITE.
<br />AREA NOT IN CONTRACT (N.I.C.)
<br />2.1
<br />EXISTING GYP. BD. HARD LID CEILING TO REMAIN. CLEAN, PATCH AND REPAIR AS REQUIRED. PAINT, SEE FINISH
<br />PLAN.4.1
<br />EXISTING LIGHT FIXTURES TO REMAIN, REPLACE BULBS THROUGHOUT. CLEAN AND REPAIR AS REQUIRED. RETURN
<br />AND BULBS IN GOOD CONDITION TO BUILDING STORAGE OR AS DIRECTED BY OWNER.4.2
<br />FINISH LEGEND
<br />WALL FINISH
<br />TYPE OF FINISH
<br />FINISH NUMBER
<br />SPECIAL FINISH
<br />TYPE OF FINISH
<br />FINISH NUMBER
<br />XX
<br />XX
<br />XX
<br />XX
<br />PATTERN DIRECTION
<br />FLOOR BASE
<br />TYPE OF FINISH
<br />FINISH NUMBER
<br />FLOOR FINISH
<br />TYPE OF FINISH
<br />FINISH NUMBER
<br />XX
<br />XX
<br />XX
<br />XX
<br />FLOOR TRANSITION
<br />FINISH SCHEDULE
<br />1.10
<br />TYP.
<br />1.1
<br />TYP.
<br />1.4
<br />TYP.
<br />1.5
<br />2.1
<br />TYP.
<br />2.2 1.7
<br />A ENLARGED DEMOLITION PLAN
<br />SCALE: 1/4" = 1'-0"
<br />1.13 1.9
<br />1.7 1.13 1.9
<br />1.10
<br />TYP.
<br />1.4
<br />TYP.
<br />1.5
<br />1.1
<br />TYP.
<br />1.11
<br />1.11
<br />1.11
<br />2.3
<br />2.2
<br />2.3
<br />4.1
<br />TYP.
<br />4.2
<br />4.2 4.2 4.2
<br />4.2
<br />4.24.24.2
<br />4.24.2
<br />4.24.2
<br />4.2 4.2
<br />4.2 4.2
<br />4.1
<br />TYP.
<br />4.1
<br />TYP.
<br />4.1
<br />TYP.
<br />P
<br />1
<br />P
<br />1
<br />WOMEN'S SHOWER
<br />& RESTROOM
<br />179
<br />MEN'S SHOWER
<br />& RESTROOM
<br />180
<br />WOMEN'S SHOWER
<br />& RESTROOM
<br />179
<br />MEN'S SHOWER
<br />& RESTROOM
<br />180
<br />WOMEN'S SHOWER
<br />& RESTROOM
<br />179
<br />EXISTING PARTITION TO REMAIN. PATCH AND REPAIR AS REQUIRED.1.1:FIELD PAINT
<br />:REFER TO PLANS
<br />:DUNN EDWARDS
<br />:DEW365 PRECIOUS PEARLS
<br />:EGGSHELL AT WALL, SEMI GLOSS AT RESTROOMS, FLAT AT CEILING
<br />:2 COATS MINIMUM
<br />ITEM
<br />LOCATION
<br />MANUFACTURER
<br />COLOR
<br />FINISH
<br />INSTALLATION
<br />P
<br />1
<br />PROVIDE ALTERNATE PRICING TO PROVIDE EPOXY COATING OVER EXISTING FLOOR TILE.
<br />SPECIFICATION: TBDA
<br />B
<br />2.8
<br />2.8
<br />PATCH EXISTING GYP. BD. HARD LID CEILING. MATCH EXISTING CONSTRUCTION. PAINT, SEE FINISH PLAN.4.3
<br />4.3
<br />4.3
<br />4.3
<br />4.3
<br />1.2
<br />1.2
<br />RELOCATED PLUMBING FIXTURE IN ACCESSIBLE STALL. MOUNTING HEIGHT ON WALL TO COMPLY WITH
<br />11B-604.2. RE-ROUTE AND CONNECT TO EXISTING PLUMBING LINE. PATCH AND REPAIR WALL AND FLOOR
<br />DAMAGED BY FIXTURE RELOCATION. SEE PLUMBING DRAWINGS.
<br />2.2
<br />EXISTING SHOWER TO REMAIN. CLEAN AND REPAIR DAMAGES, RE-GROUT TILE THROUGHOUT.2.4
<br />NEW WALL WITH 12" HIGH CLERESTORY WINDOWS AT 12" BELOW CEILING. PROVIDE FROSTED FILM ON
<br />WINDOWS. PROVIDE TILE AND WATER PROOFING MEMBRANE. TILE TO MATCH EXISTING.2.5
<br />NEW RESTROOM ACCESSORIES AS SPECIFIED ON PLUMBING FIXTURE SCHEDULE ON SHEET A-0.7. RE-USE
<br />EXISTING ACCESSORIES IN GOOD CONDITION, PROVIDE NEW FOR ACCESSORIES IN BAD CONDITION.
<br />2.3
<br />2.6
<br />1.2
<br />EXISTING FINISHES TO REMAIN, PROTECT IN PLACE. CLEAN AND RE-GROUT ALL FLOOR AND WALL TILES. PATCH
<br />AND REPAIR DAMAGED TILES AND FINISHES AFFECTED BY DEMOLITION. MATCH EXISTING FINISHES.1.4
<br />SKIM COAT WALLS AS REQUIRED TO PREPARE FOR NEW WALL PAINT, SEE FINISH SCHEDULE.1.5
<br />REMOVE EXISTING RESTROOM ACCESSORIES AND STALL PARTITIONS. RETURN ACCESSORIES IN GOOD CONDITION
<br />TO BUILDING STORAGE OR AS DIRECTED BY BUILDING OWNER.
<br />1.6
<br />EXISTING RESTROOM ACCESSORY TO REMAIN. CLEAN AND REPAIR AS REQUIRED. PROVIDE NEW IF EXISTING
<br />FIXTURE IS IN BAD CONDITION. SEE FIXTURE SCHEDULE ON SHEET A-0.7.1.3
<br />REMOVE EXISTING PLUMBING FIXTURE, SAVE FOR RELOCATION. CLEAN AND REPAIR PLUMBING FIXTURE AS
<br />REQUIRED. RE-USE AND RE-ROUTE PLUMBING LINE TO NEW LOCATION OF FIXTURE. SEE CONSTRUCTION PLAN.1.7
<br />1.8
<br />EXISTING PLUMBING FIXTURE TO REMAIN, PROTECT IN PLACE. CLEAN AND REPAIR PLUMBING FIXTURE AS
<br />REQUIRED.1.9
<br />1.10
<br />EXISTING SINK AND COUNTER TO REMAIN, PROTECT IN PLACE. CLEAN AND REPAIR DAMAGES AS REQUIRED.
<br />CLEAN, PATCH AND REPAIR ALL FINISHES AFFECTED BY SCOPE. MATCH EXISTING FINISHES.5.1
<br />5.2
<br />PROVIDE NEW FULL-HEIGHT FROSTED FILM ON GLASS SHOWER DOOR.5.3
<br />REMOVE INTERIOR TENANT NON-LOAD BEARING WALL AND ASSOCIATED ELECTRICAL, DATA, TELEPHONE AND
<br />J-BOXES U.O.N. REMOVE ALL WIRING BACK TO ELECTRICAL SUB-PANEL.
<br />1.8
<br />TYP.
<br />1.8
<br />TYP.
<br />CONTRACTOR TO REMOVE EXISTING DOORS AND FRAMES, REUSE/ RELOCATE ALL EXISTING DOOR ASSEMBLIES IN
<br />NEW BUILD-OUT OR RETURN TO BUILDING STORAGE AS DIRECTED BY BUILDING OWNER.
<br />1.11
<br />REMOVE EXISTING DRINKING FOUNTAIN. CAP PLUMBING LINES. PATCH AND REPAIR WALLS AFFECTED BY
<br />DEMOLITION.1.12
<br />1.12
<br />1.11
<br />1.8
<br />1.8
<br />1.8
<br />1.8
<br />NEW SHOWER CURTAIN AND STAINLESS STEEL CURTAIN ROD.2.7
<br />NEW LOCKERS, SEE SPECIFICATION ON FIXTURE SCHEDULE ON SHEET A-0.7. 5% OF LOCKERS TO BE ADA
<br />COMPLIANT AND PROVIDE WITH AN ADA LOGO STICKER. PROVIDE KEYLESS HASP LOCKS.2.8
<br />NEW WALL TO UNDERSIDE OF CEILING. PROVIDE INSULATION IN STUD CAVITY. SEE DETAIL 1/A-30.0.2.9
<br />RELOCATED DOOR. CLEAN AND REPAIR DOOR. RE-USE FRAME AND HARDWARE, PROVIDE NEW IF NOT POSSIBLE
<br />TO RE-USE. GC TO CONFIRM IN FIELD.2.11
<br />B
<br />B
<br />2.5
<br />2.5
<br />2.6
<br />TYP.
<br />2.6
<br />TYP.2.7
<br />2.6
<br />2.6
<br />2.9
<br />TYP.
<br />2.11
<br />2.11
<br />5'
<br />-
<br />0
<br />"
<br />MI
<br />N
<br />.
<br />5'-0"
<br />5'-0"
<br />5'
<br />-
<br />0
<br />"
<br />MI
<br />N
<br />.
<br />3'-0"
<br />MIN.
<br />2.73'
<br />-
<br />0
<br />"
<br />CL
<br />R
<br />.
<br />
<br />O
<br />P
<br />N
<br />G
<br />.
<br />3'
<br />-
<br />0
<br />"
<br />CL
<br />R
<br />.
<br />
<br />O
<br />P
<br />N
<br />G
<br />.
<br />3'-0"
<br />MIN.
<br />2.9
<br />TYP.
<br />5.3
<br />5.3
<br />5.1 5.2
<br />A B
<br />5.1 5.2
<br />A B
<br />NEW FURRING WALL TO UNDERSIDE OF CEILING. SEE DETAIL 2/A-30.0.2.10
<br />10"
<br />2.10
<br />TYP.
<br />2.1
<br />TYP.
<br />2.10
<br />10"
<br />PROVIDE ALTERNATE PRICING FOR REPLACING EXISTING SHOWER FIXTURE.
<br />MANUF: MOEN
<br />MODEL: 8342, 8342EP15
<br />FINISH:POLISH CHROME
<br />NOTE:INCLUDE ALL PIECES REQUIRED FOR THIS SYSTEM TO WORK PROPERLY
<br />C
<br />C
<br />C
<br />C
<br />C
<br />PROVIDE ALTERNATE DEDUCT PRICING FOR PROVIDING FULL-HEIGHT ACCORDION FOLDING DOOR AT ENTRY INTO
<br />SHOWERS IN LIEU OF NEW WALL AT ADA SHOWER. PROVIDE FULL LENGTH CURTAIN ROD AND CURTAIN AT
<br />SHOWER IN LIEU OF WALL.
<br />D
<br />D
<br />D
<br />EXISTING STALL PARTITIONS TO REMAIN. CLEAN AND REPAIR AREAS DAMAGED BY DEMOLITION.
<br />PROVIDE ALTERNATE FOR REPLACING EXISTING EXISTING FLUSH VALVES WITH NEW AUTOMATIC FLUSH VALVES
<br />AT PLUMBING FIXTURES AND REPLACING EXISTING SINK FAUCETS WITH NEW AUTOMATIC FAUCETS AND
<br />PROVIDING NEW SOAP DISPENSERS AT SINKS. SEE SPECIFICATION ON FIXTURE SCHEDULE ON SHEET A-0.7.
<br />NEW RESTROOM PARTITION PER FIXTURE SCHEDULE ON SHEET A-0.7. PROVIDE NEW PARTITION FOR ACCESSIBLE
<br />STALLS AND STALLS AFFECTED BY SCOPE.
<br />1.3
<br />1.6
<br />1.6
<br />TYP.
<br />REMOVE EXISTING PLUMBING FIXTURES. CAP PLUMBING LINES. PATCH AND REPAIR WALLS AFFECTED BY
<br />DEMOLITION.1.13
<br />2.10
<br />B
<br />B
<br />EXISTING PLUMBING FIXTURE TO REMAIN. CLEAN AND REPAIR PLUMBING FIXTURE AS REQUIRED.
<br />2.4
<br />2.4
<br />2.6
<br />2.6
<br />B
<br />B
<br />C
<br />C
<br />2.9
<br />2.9
<br />ALTERNATE NOTES
<br />C
<br />C
<br />REPLACE ANY WALL AND FLOOR TILE AFFECTED BY SCOPE. CLEAN AND RE-GROUT ALL FLOOR AND WALL TILE.
<br />MATCH EXISTING FINISHES.
<br />NELSON
<br />ALGAZE
<br />No. C-21090
<br />REN. 03/31/2025
<br />L
<br />CENSE ARC
<br />EC
<br />SAE O CAL ORNA
<br />1700 E St Andrew Pl -
<br />ADA Upgrades12/2/2024
|