Laserfiche WebLink
P1.47 <br />Saint Andrew Accessibility Upgrades <br />1700 East Saint Andrew Place, Santa Ana, California 92705 <br />24-7734 <br />6/21/2024 <br />NN <br />GATE DESIGN: <br />Pole Footing under HSS Post: <br />Loads on HSS Post: <br />PD = 16ft gate weight = 500lbs <br />MD = MD,16ft gate = 500lbs x 16ft/2 = 4000lbs.ft <br />PLL = 250lbs <br />PW,16ft gate = 1451lbs <br />PW = PW,16ft gate = 1451lbs <br />MW, 16ft gate = 1451lbs x 16ft/2 = 11,608lbs.ft <br />MW = MW, 16ft gate = 11,608lbs.ft <br />**See next page for Enercalc design report <br />Lateral Bearing Pressure = 100psf/ft (CBC 2022, table 1806.2) <br />As per section 1806.3.3, lateral bearing pressure can be increased for <br />each additional foot. Assuming 3ft depth, lateral bearing pressure = <br />300psf/ft <br />**See next page for Enercalc Report <br />1700 E St Andrew Pl - <br />ADA Upgrades12/2/2024