Laserfiche WebLink
6.0 Design Loads - Downward (Cont.): <br />6.2 Racking Dimensions for Point Loads (Cont.): <br />Fig. 6.2 Section A-A <br />6.3 Point Load Summary:Notes: <br />DLsys = 103 lbs./module -Base 2 repeat for larger width arrays. <br />Total DL = (Varies on location and ballast quantity) <br />SLm = 0 lbs./module <br />WLin (no snow) = 659 lbs./module <br />WLin (with snow) = 175 lbs./module <br /> <br /> <br />Max Total Load Per Base (lbs.) <br />load combinations (ASD) <br />Location Base <br />DL + Snow DL + 0.6Wlin DL + 0.75SLm + 0.75(0.6WLin) <br />South 1 72 171 91 <br />Interior 2 105 303 145 <br />2nd From North 3 93 291 132 <br />North 4 137 236 157 <br />Table 6.1-A Max Total Load per Base (lbs.) <br /> <br />Max Contact Pressure Table Per Base (psi) <br />load combinations (ASD)# of <br />Pads <br />Location Base <br />DL + Snow DL + 0.6Wlin DL + 0.75SLm + 0.75(0.6WLin) <br />South 1 4 9 5 <br />Interior 2 6 16 8 <br />2nd From North 3 5 16 7 <br />2 <br />North 4 7 13 9 <br />South 1 2 5 2 <br />Interior 2 3 8 4 <br />2nd From North 3 3 8 4 <br />4 <br />North 4 4 6 4 <br />Table 6.1-B Max Point Load Summary (psi) <br />11/04/2024 <br />APPROVED FOR CONSTRUCTION <br />12 <br />PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 <br />(978) 688.4900 - www.panelclaw.com <br />1330 E Seventeenth <br />St4/10/2025