Laserfiche WebLink
7.0 Design Loads - Seismic (Cont.): <br />7.4 Vertical Seismic Force Check: <br />Mechanical attachments may be required for several reasons including building code, roof load limits and array shape. The table <br />below provides the mechanical attachment requirements for each sub-array within this project. <br /> <br />Nomenclature: <br />WP = Sub-Array Weight <br />FPV = Vertical Seismic Force <br />FRV = Vertical Seismic Resisting Force <br /> <br />Array Information Vertical Force Verification Results <br />Sub- <br />Array <br />Name <br />WP <br />(lbs.) <br />FPV <br />(lbs.) <br />FRV <br />(lbs.) <br />0.7 FPV - <br />FRV (lbs.) <br />MA's <br />Required <br />Total MA <br />Capacity <br />(lbs.) <br />Total <br />MA's <br />Provided <br />Acceptable <br />1.1 6,037 1,259 3,622 -2,741 0 2,276 7 Yes <br />1.2 20,144 4,200 12,086 -9,146 0 0 0 Yes <br />1.3 3,447 719 2,068 -1,565 0 0 0 Yes <br />1.4 4,725 985 2,835 -2,145 0 0 0 Yes <br />1.5 5,506 1,148 3,303 -2,500 0 0 0 Yes <br />1.6 5,300 1,105 3,180 -2,406 0 0 0 Yes <br />1.7 3,310 690 1,986 -1,503 0 0 0 Yes <br />1.8 20,146 4,200 12,087 -9,147 0 0 0 Yes <br />1.9 10,508 2,191 6,305 -4,771 0 0 0 Yes <br />1.10 3,250 678 1,950 -1,476 0 0 0 Yes <br />1.11 4,324 901 2,594 -1,963 0 0 0 Yes <br />1.12 2,127 443 1,276 -966 0 0 0 Yes <br />Total:88,823 lbs.18,518 lbs.53,294 lbs.-40,331 lbs.0 2,276 7 <br /> <br />Table7.2 - Summary of Mechanical Attachment Requirements <br />* MA's Required = 0.7 FPV - FRV/MA strength <br />11/04/2024 <br />APPROVED FOR CONSTRUCTION <br />17 <br />PanelClaw, Inc., 1600 Osgood Street, Suite 2023, North Andover, MA 01845 <br />(978) 688.4900 - www.panelclaw.com <br />1330 E Seventeenth <br />St4/10/2025