My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010 & 2012 N Bush Ave, #100 and #101 - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bush St
>
2012 N Bush St Unit# 100
>
2010 & 2012 N Bush Ave, #100 and #101 - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 2:35:24 AM
Creation date
6/6/2025 1:18:39 PM
Metadata
Fields
Template:
Plan
Permit Number
101121423
101121424
Full Address
2012 N Bush St Unit# 100
2012 N Bush St Unit# 101
Street Number
2012
2012
Street Direction
N
N
Street Name
Bush
Bush
Street Suffix
St
St
Unit Number
100
101
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
139
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
GEO-ETKA, INC. <br /> Job No: F-12136-24 <br />3 <br />Laboratory Testing (cont’d) <br /> <br />The method of performing these tests is to saturate the sample, to extrude the sample <br />into the test apparatus, to apply the normal load, and than to allow sufficient time to <br />elapse to dissipate any excess hydrostatic pressure. The sample is then subjected to a <br />strain-controlled single plane shear test. <br /> <br />The method of applying the normal and shearing load is such as to allow the sample to <br />change in volume without producing an associated change in the normal stress. The <br />shearing stress is measured at a constant rate of strain of approximately 0.05 inches <br />per minute. <br /> <br />Selected samples of soil were tested at confining pressures similar to those of the <br />materials in-situ. Additional specimens from the same samples were also tested at <br />increased normal pressures in order to determine the increase in shear strengths <br />associated with increased inter-granular pressure. The test results are plotted <br />graphically on Plate “C”. The resulting values are as follows: <br /> <br /> <br /> <br />CONCLUSIONS <br /> <br />Suitability of the Project <br /> <br />The site is suitable for its intended use i.e. a 2 ADU units. In designing the proposed <br />structure, the criteria given in the design section should be adhered to. <br /> a. The construction of this project will not affect the stability of the surrounding <br />structures, such as walls, electric poles, etc., provided all precautions needed are <br />followed. <br />b. The latest applicable unified building code is to be followed as required. <br />c. This report is subject to approval by the governing agencies. <br /> <br /> <br />Strength Characteristics <br /> <br />The load bearing soils possess strength parameters adequate to support the proposed <br />construction. <br /> <br /> <br /> <br /> Angle of Internal Cohesion <br />Soil Type Friction (degrees) (p.s.f.) <br /> <br /> Silty Sand 28 ½ 70 <br /> Silty Sand 30 100 <br />2010 & 2012 N Bush Ave, <br />#100 and #1012/21/2025
The URL can be used to link to this page
Your browser does not support the video tag.