My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1312 S Hickory St - Plan
PBA
>
Building
>
ProjectDox
>
H
>
Hickory St
>
1312 S Hickory St
>
1312 S Hickory St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:20:17 PM
Creation date
6/6/2025 1:20:01 PM
Metadata
Fields
Template:
Plan
Permit Number
20185628
Full Address
1312 S Hickory St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Powerwall 3 <br />Power Everything <br />2024 <br /> — <br />Powerwall 3 is a fully integrated solar and battery system, designed to accelerate the transition to sustainable energy. <br />Customers can receive whole home backup, cost savings, and energy independence by producing and consuming their <br />own energy while participating in grid services. Once installed, customers can manage their system using the Tesla App to <br />customize system behavior to meet their energy goals. <br />Powerwall 3 achieves this by supporting up to 20 kW DC of solar and providing up to 11.5 kW AC of continuous power per <br />unit. It has the ability to start heavy loads rated up to 185 LRA, meaning a single unit can support the power needs of most <br />homes. Powerwall 3 Expansions make it easier and more affordable to scale up customers’ systems to meet their current or <br />future needs.Powerwall 3 is designed for fast and ef cient installations,modular system expansion,and simple connection to <br />any electrical service. <br />22024Powerwall 3 Datasheet <br />Powerwall 3 Technical Specifications <br />System Technical <br />Speci cations <br />Model Number 1707000-xx-y <br />Nominal Grid Voltage (Input & Output)120/240 VAC <br />Grid Type Split phase <br />Frequency 60 Hz <br />Nominal Battery Energy 13.5 kWh AC 1 <br />Nominal Output Power (AC)5.8 kW 7.6 kW 10 kW 11.5 kW <br />Maximum Apparent Power 5,800 VA 7,600 VA 10,000 VA 11,500 VA <br />Maximum Continuous Current 24 A 31.7 A 41.7 A 48 A <br />Overcurrent Protection Device 2 30 A 40 A 60 A 60 A <br />Con gurable Maximum Continuous Discharge <br />Power Off-Grid (PV Only, -20°C to 25°C) <br />15.4 kW 3 <br />Maximum Continuous Charge Current / Power <br />(Powerwall 3 only) <br />20.8 A AC / 5 kW <br />Maximum Continuous Charge Current / Power <br />(Powerwall 3 with up to (3) Expansion units) <br />33.3 A AC / 8 kW <br />Output Power Factor Rating 0 -1 (Grid Code con gurable) <br />Maximum Output Fault Current (1 s)160 A <br />Maximum Short-Circuit Current Rating 10 kA <br />Load Start Capability 185 LRA <br />Solar to Battery to Home/Grid Ef ciency 89% 1,4 <br />Solar to Home/Grid Ef ciency 97.5% 5 <br />Power Scalability Up to 4 Powerwall 3 units supported <br />Energy Scalability Up to 3 Expansion units (for a maximum total of 7 units) <br />Supported Islanding Devices Gateway 3, Backup Switch, Backup Gateway 2 <br />Connectivity Wi-Fi (2.4 and 5 GHz),Ethernet,Cellular (LTE/4G 6) <br />Hardware Interface Dry contact relay,Rapid Shutdown (RSD)certi ed switch <br />and 2-pin connector, RS-485 for meters <br />AC Metering Revenue Grade (+/-0.5%,ANSI C12.20) <br />Protections Integrated arc fault circuit interrupter (AFCI),Isolation <br />Monitor Interrupter (IMI),PV Rapid Shutdown (RSD)using <br />Tesla Mid-Circuit Interrupters <br />Customer Interface Tesla Mobile App <br />Warranty 10 years <br />1 Values provided for 25°C (77°F),at beginning of life.3.3 kW charge/discharge power. <br />2 See Powerwall 3 Installation Manual for fuse requirements if using fuse for overcurrent protection. <br />3 15.4kW off-grid maximum continuous discharge power is only available if on-grid rating is 11.5 kW. If enabled, Powerwall 3 <br />must be installed with an 80 A breaker and appropriately sized conductors. <br />4 Typical solar shifting use case. <br />5 Tested using CEC weighted ef ciency methodology. <br />6 The customer is expected to provide internet connectivity for Powerwall 3; cellular should not be used as the primary mode of <br />connectivity. Cellular connectivity subject to network operator service coverage and signal strength. <br />1312 S Hickory St <br />5/5/2025
The URL can be used to link to this page
Your browser does not support the video tag.