Laserfiche WebLink
Wa <br />s <br />h <br />e <br />r <br />Dr <br />y <br />e <br />r <br />REF. <br />DW <br />280 CFM Vent <br />Hood <br />Min. 50 CFM W/Humidity sensor <br />exhaust fan W/Min. 5 air changes <br />per hour. <br />Fans shall be Energy Star compliant <br />and be ducted to terminate outside <br />of the building. <br />SYMBOLS: <br />Smoke & Carbon Monoxide <br />Combination Detector <br />S/C <br />Hard wired Smoke Detector <br />W/backup battery <br />SD <br />Hard wired Carbon MonoxideCM <br />Recessed Can Lights (LED Lights) <br />Outlet (AFCI) <br />Outlet GFCI (Ground Fault Circuit <br />Interrupter)GFCI <br />Outlet GFCI (Ground Fault Circuit <br />Interrupter) / WaterproofGFCI <br />WP <br />Outlet - Cable / TV /Phone <br />Switch <br />Switch W/Occupancy SensorOS <br />ATTIC VENTILATION CALCULATIONS <br />ATTIC VENTILATION SHALL NOT BE LESS THAN 1/150 <br />OF THE AREA OF THE SPACE VENTILATED. <br />TOTAL ROOF AREA VENTILATION AREA REQ. <br />500 SQ FT 3.5 SQ FT <br />VENT SIZE & AREA TOTAL No. OF VENTS -> VNET AREA <br />24" x 12" Dormer = .7 SQ FT 5 VENTS @ .7 SQ FT <br />REQUIRED < PROVIDED <br />3.5 SQ FT < 3.5 SQ FT <br />DORMER <br />VENT <br />DORMER <br />VENT <br />DORMER <br />VENT <br />Roofing Material Type <br />Class "A" Shingles per <br />ICC # ESR-1745 <br />To match existing <br />DORMER <br />VENT <br />DORMER <br />VENT <br />(N <br />) <br /> <br />3 <br /> <br />: <br />1 <br />2 <br />(N <br />) <br /> <br />3 <br /> <br />: <br />1 <br />2 <br />(E) 4 :12 <br />(E <br />) <br /> <br />4 <br /> <br />: <br />1 <br />2 <br />(E <br />) <br /> <br />4 <br /> <br />: <br />1 <br />2 <br />1' - 0" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />7' - 6" <br />16' - 10 1/2" <br />23 <br />' <br /> <br />- <br /> <br />0 <br />" <br />1' <br /> <br />- <br /> <br />0 <br />" <br />19' - 0" <br />5 <br />A2 <br />6 <br />A2 <br />EX <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />E <br />A <br />V <br />E <br /> <br />T <br />O <br /> <br />B <br />E <br /> <br />D <br />E <br />M <br />O <br />L <br />I <br />S <br />H <br />E <br />D <br />1 <br />H <br />O <br />U <br />R <br /> <br />F <br />I <br />R <br />E <br /> <br />R <br />A <br />T <br />E <br />D <br /> <br />E <br />A <br />V <br />E <br /> <br />P <br />E <br />R <br /> <br />D <br />E <br />T <br />A <br />I <br />L <br /> <br />( <br />I <br />F <br /> <br />A <br />P <br />P <br />L <br />I <br />C <br />A <br />B <br />L <br />E <br />) <br />GFCI <br />WP <br />Linen <br />GF <br />C <br />I <br />WP <br />GF <br />C <br />I <br />WP <br />GF <br />C <br />I <br />WP <br />GFCI <br />WP <br />GFCI <br />WP <br />GFCI <br />WP <br />SHEET TITLE: <br />SCALE: <br />SHEET NO. <br />PR <br />O <br />J <br />E <br />C <br />T <br />DA <br />T <br />E <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />PROJECT NUMBER: <br />OWNER / CLIENT: <br />DATE ISSUED: <br />DATE SUBMITTED: <br />DRAWN BY: <br />CHECKED BY: <br />THESE DRAWINGS ARE THE PROPERTY <br />OF TREEIUM INC AND SHALL NOT BE <br />USED ON ANY OTHER WORK EXCEPT <br />BY AGREEMENT WITH TREEIUM INC <br />48 <br />2 <br />1 <br /> <br />L <br />A <br />N <br />K <br />E <br />R <br />S <br />H <br />I <br />M <br /> <br />B <br />L <br />V <br />D <br /> <br />S <br />T <br />E <br /> <br />F <br /> <br /># <br />4 <br />4 <br />5 <br /> <br />NO <br />R <br />T <br />H <br /> <br />H <br />O <br />L <br />L <br />Y <br />W <br />O <br />O <br />D <br />, <br /> <br />C <br />A <br />31 <br />0 <br />. <br />6 <br />9 <br />4 <br />. <br />0 <br />8 <br />3 <br />5 <br />WW <br />W <br />. <br />A <br />V <br />D <br />E <br />S <br />I <br />G <br />N <br />. <br />L <br />A <br />AV <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br />As indicated <br />AVD24D019 <br />Debbini, Lubna <br />Roof + <br />Electrical Plan <br />A3 <br />To <br />w <br />n <br />e <br />r <br /> <br />A <br />D <br />U <br />11 <br />0 <br />8 <br /> <br />N <br /> <br />T <br />o <br />w <br />n <br />e <br />r <br /> <br />S <br />t <br /> <br />& <br /> <br />1 <br />1 <br />0 <br />8 <br /> <br />N <br />To <br />w <br />n <br />e <br />r <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br /> <br /># <br />2 <br />Sa <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br />ER/CB <br />Checker <br />--- <br />A. PANEL LOCATIONS <br />PANELS SHALL NOT BE LOCATED IN THE VICINITY OF EASILY GINITABLE MATERIAL, SUCH AS CLOTHES CLOSETS, OR IN <br />BATHROOMS [CEC 240-24(D)] <br />B.NON-METALLIC SHEATHED CABLE [CEC 334] <br />NON-METALLIC SHEATHED CABLE SHALL BE: <br />1. PROTECTED BY RIGID METAL CONDUIT, ELECTRICAL METALLIC, TUBING SCHEDULE 80 PVC CONDUIT, PIPE OR OTHER <br />MEANS WHEN CABLE IS EXPOSED OR SUBJECT TO PHYSICAL DAMAGE. [CEC 334.15(B)] <br />2. PROTECTED BY A 1/16” STEEL PLATE OR SLEEVE OR BE NOT LESS THAN 1-1/4" FROM THE NEAREST EDGE OF THE <br />FRAMING MEMBER, WHEN INSTALLED THROUGH FRAMING MEMBERS. STEEL PLATES ARE SLEEVES ARE REQUIRED ON ALL <br />DOUBLE SHEAR WALLS WHEN CABLE IS INSTALLED EITHER THROUGH PARALLEL TO FRAMING MEMBERS [CEC 334.17] <br />3.PROTECTED BY GUARD STRIPS WITHIN 6 FEET OF AN ATTIC ACCESS WHEN NO PERMANENT STAIRS OR LADDERS ARE <br />PROVIDED [CEC 334.23, 320.23] <br />4.PROTECTED BY GUARD STRIPS IN THE ENTIRE ATTIC WHEN PERMANENT STAIRS OR LADDER ARE PROVIDED. ACCESS <br />PANELS OR DOOR FROM THE SECOND FLOOR INTO THE ATTIC ARE CONSIDERED PERMANENT ACCESS AND GUARD STRIPS <br />ARE REQUIRED IN THE ENTIRE ATTIC. <br />5. HAVING A BENDING RADIUS NOT LESS THAN 5 TIMES THE DIAMETER OF THE CABLE [CEC 334.24] <br />6. SUPPORTED AT INTERVALS NOT EXCEEDING 4-1/2 FEET AND WITHIN 12 ” OF EVERY OUTLET BOX, JUNCTION BOX, CABINET <br />OR FITTING [CEC 334.30] <br />C.CIRCUITS AND RECEPTACLES <br />1. TAMPER-RESISTANT RECEPTACLES SHALL BE INSTALLED AS SPECIFIED IN DWELLING UNITS IN ALL AREAS SPECIFIED <br />IN 210.52 [CEC 406.12] <br />2.RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT ALONG THE FLOOR LINE IN ANY WALL SPACES IS MORE THAN <br />6 FT FROM AN OUTLET, INCLUDING ANY WALL SPACE 2FT WIDE OR GREATER. NOTE: A FIXED PANEL OF SLIDING GLASS DOOR <br />IS CONSIDERED WALL SPACE. [CEC 210.52(A)]. <br />3. IN KITCHENS, BREAKFAST ROOMS, PANTRIES AND DINING ROOMS A MINIMUM OF 2-20A CIRCUITS SHALL BE PROVIDED <br />[CEC 210.11(C)(1)]. COUNTER SPACE RECEPTACLES SHALL BE GFCI [CEC 210.8(A)] AND INSTALLED: <br />3.1.AT EACH WALL COUNTER SPACE THAT IS 12IN. OR GREATER [CEC 210.52(C)(1)] <br />3.2.NO MORE THAN 48IN. O.C. [CEC 210.52(C)(1)] <br />3.3.MAXIMUM 24IN. FROM THE END OF THE SURFACE [CEC 210.52(C)(1)] <br />3.4.MAXIMUM 20IN. ABOVE COUNTER SURFACE [CEC 210.52(C)(5)] <br />3.5.ON ISLAND COUNTER SPACES (ONE RECEPTACLE MIN) NOT MORE THAN 12IN. BELOW COUNTER SURFACE <br />[CEC 210.52(C)(5) EXEMPTION]. AN ISLAND WITH LESS THAN 12IN BEHIND A RANGE TOP OF SINK IS CONSIDERED AS DIVING <br />THE COUNTERTOP INTO TWO SEPARATE SPACES [CEC 210.52(C)(2)] <br />3.6.ON PENINSULAR COUNTER SPACES (ONE RECEPTACLE MIN) NOT MORE THAN 12IN. BELOW COUNTER <br />SURFACE [CEC 210.52 (C)(5) EXCEPTION] <br />4.BATHROOMS SHALL HAVE A SEPARATE 20A CIRCUIT [CEC 210.11(C)(3)] WITH AT LEAST ONE GFCI WALL RECEPTACLES <br />WITHIN 36IN OF EACH BASIN [CEC 210.8(A)(1); CEC 210.52(D)] <br />5.LAUNDRY ROOMS SHALL HAVE A SEPARATE 20A CIRCUIT WITH AT LEAST ONE RECEPTACLE SHALL BE PROVIDED [CEC <br />201.11(C)(2)]. ALL RECEPTACLES WITHIN 6 FT. OF THE SINK SHALL BE GFCI <br />6.IN GARAGES, AT LEAST ONE GFCI RECEPTACLE SHALL BE PROVIDED [CEC 210.52(G)]. ALL OTHER GARAGE <br />RECEPTACLES EXCEPT THOSE DEDICATED TO AN APPLIANCE OR THAT ARE NOT READILY ACCESSIBLE SHALL BE GFCI [CEC <br />210.8(A)(2)] <br />7.IN HALLWAYS OF 10 FT. OR MORE IN LENGTH, AT LEAST ONE RECEPTACLE SHALL BE PROVIDED [CEC 210.8(A)(7)] <br />8.OUTDOOR OUTLETS SHALL BE GFCI [CEC 210.8(A)(3)]. ONE OUTLET SHALL BE INSTALLED AT THE FRONT OF THE <br />DWELLING AND ONE AT THE REAR OF THE DWELLING. RECEPTACLES SHALL BE ACCESSIBLE AT GRADE LEVEL AND NOT <br />MORE THAN 6-1/2 FT. ABOVE GRADE [CEC 210.52(E)] <br />9.ALL CRAWL SPACE RECEPTACLES SHALL BE GFCI [CEC 210.8(A)(4)] <br />10.ALL INFINISHED BASEMENT RECEPTACLES SHALL BE GFCI [CEC 210.8(A)(5)] OR ARE SERVICE A DEDICATED <br />APPLIANCES [CEC 210.8(A)(5)] <br />11. ALL RECEPTACLES WITHIN 6 FT. OF A WET BAR SHALL BE GFCI [CEC 210.8(A)(7)] <br />12.ALL RECEPTACLES ON 15A OR 20A BRANCH CIRCUITS THAT SUPPLY FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, <br />PARLORS, LABRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS HALLWAYS OR SIMILAR ROOMS OR <br />AREAS SHALL BE PROTECTED BY COMBINATION-TYPE-ARC-FAULT CIRCUIT INTERRUPTERS (AFCI), INCLUDING SWITCHED <br />OUTLETS [CEC 210.12(A)] <br />13.ALL RECEPTACLES SERVING APPLIANCES OR MOTORS WITH A RATING OF 1 HP OR 6 AMPS SHALL BE ON A SEPARATE <br />CIRCUIT. <br />14.FOR HVAC EQUIPMENT, A SEPARATE 15A OR 20A CIRCUIT WITH AN ACCESSIBLE RECEPTACLE AT THE EQUIPMENT <br />SHALL BE PROVIDED WITHIN 25 FT OF THE EQUIPMENT [CEC 210.63]. IF LOCATED IN AN UNDER-FLOOR AEA, THE RECEPTACLE <br />SHALL BE GFCI [CEC 210.8(4)] <br />15. BASEMENT, GARAGES AND ACCESSORY BUILDINGS. FOR ONE-FAMILY DWELLING, AT LEAST ONE RECEPTACLE OUTLET <br />SHALL BE INSTALLED IN THE AREAS SPECIFIED IN 210.2(G)(1) THROUGH (3)/ THESE RECEPTACLES SHALL BE IN ADDITION TO <br />RECEPTACLES REQUIRED FOR SPECIFIC EQUIPMENT. <br />15.1.GARAGES. IN EACH ATTACHED GARAGE AND IN EACH DETACHED GARAGE WITH ELECTRICAL POWER THE <br />BRANCH CIRCUIT SUPPLYING THIS RECEPTACLE(S) SHALL NOT SUPPLY OUTLETS OF SIDE OF THE GARAGE. AT LEAST ONE <br />RECEPTACLE OUTLET SHALL BE INSTALLED FOR EACH CAR SPACE. <br />15.2.ACCESSORY BUILDINGS. IN EACH ACCESSORY BUILDING WITH ELECTRICAL POWER. <br />15.3.BASEMENT. IN EACH SEPARATE UNFINISHED PORTION OF A BASEMENT. <br />D.LIGHTING [CEC 210.70] <br />1.SWITCHED LIGHTING SHALL BE INSTALLED IN: <br />1.1 ALL HABITABLE ROOMS, BATHROOMS, HALLWAYS, AND STAIRWAYS AT EACH LEVEL. <br />1.2 GARAGES. <br />1.3 AT ALL OUTDOOR ENTRANCES AND EXITS. <br />1.4 IN ALL ATTICS, UNDER FLOOR AREAS, UTILITY ROOMS AND BASEMENTS USED FOR STORAGE. <br />1.5 NEAR HVAC EQUIPMENT IN ATTIC, UNDER FLOOR AREAS, ROOMS OR BASEMENTS, WITH A SWITCH AT THE <br />ACCESS POINT. <br />2.LIGHTING INSTALLED IN A CLOSET SHALL BE A SURFACE MOUNTED OR RECESSED FLUORESCENT FIXTURE OR <br />A SURFACE MOUNTED INCANDESCENT FIXTURE WITH COMPLETELY ENCLOSED LAMPS OR RECESSED INCANDESCENT <br />FIXTURE WITH COMPLETELY ENCLOSED LAMPS. SURFACE INCANDESCENT LIGHTING SHALL BE INSTALLED A MINIMUM OF <br />12IN. FROM THE NEAREST POINT OF A STORAGE SPACE. SURFACE FLUORESCENT LIGHTING AND RECESSED LIGHTING SHALL <br />BE INSTALLED A MINIMUM OF 6 IN. FROM THE NEAREST POINT OF A STORAGE SPACE [CEC 410.16(C)] <br />3. 100% OF THE LUMINARIES IN A KITCHEN MUST BE HIGH EFFICACY. <br />4. IN BATHROOMS, GARAGES, LAUNDRY ROOMS, AND UTILITY ROOMS, AT LEAST ONE LUMINAIRE IN EACH OF THESE <br />SPACES SHALL BE CONTROLLED BY A VACANCY SENSOR. <br />5. BEDROOMS, LIVING ROOMS, FAMILY ROOMS AND OTHER ROOMS USED FOR LIVING AND SLEEPING MUST HAVE HIGH <br />EFFICACY LIGHTING, AND MAY REQUIRE AN OCCUPANT SENSOR WITH A MANUAL-ON/AUTO-OFF FEATURE, OR DIMMERS. <br />6. EXTERIOR LIGHTING MUST BE HIGH EFFICACY, A PHOTOCELL AND MOTION SENSOR MAY BE INSTALLED. <br />E.FANS <br />1. IN BATHROOMS CONTAINING TUBS OR SHOWERS, A FAN CAPABLE OF EXHAUSTING 50 CFM SHALL BE INSTALLED <br />[ENERGY STANDARDS 150(O)] <br />2. KITCHEN REQUIRED EXHAUST FAN WITH A MINIMUM 100 CFM DUCTED TO THE EXTERIOR. <br />3. HUMIDITY CONTROLS SHALL BE CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE HUMIDITY RANGE OF 50% TO A <br />MAXIMUM 80% A HUMIDITY CONTROL MAY UTILIZE MANUAL AUTOMATIC <br />F.SMOKE ALARMS <br />IN NEW CONSTRUCTION. SMOKE ALARMS SHALL RECEIVE THEIR PRIMARY POWER FRONT THE BUILDING WIRING. THE <br />WIRING SHALL BE PERMANENT AND INSTALLED WITHOUT A DISCONNECTING SWITCH OTHER THAN THOSE REQUIRED OR <br />OVERCURRENT PROTECTION [CRC R314.4] <br />A DOMESTIC CLOTHES DRYER DUCT SHALL BE OF METAL AND A MINIMUM OF 4 ” IN DIAMETER. THE EXHAUST DUCT SHALL NOT <br />EXCEED A TOTAL COMBINED HORIZONTAL AND VERTICAL LENGTH OF 14 ’, INCLUDING TWO 90 DEGREE ELBOWS. TWO FEET <br />SHALL BE DEDUCTED FOR EACH 90 DEGREE ELBOW IN EXCESS OF TWO (504.3.1.1 & 504.3.1.2 CMC) <br />ELECTRICAL NOTES <br />NOTE ALL BATHROOMS FANS: <br />MINIMUM 50 CFM FAN TESTED AT A STATIC PRESSURE OF .25 WC AND RATED @ 3 SONES OR LESS REQUIRED TO BE INSTALLED <br />FAN MUST BE ATTACHED TO A MINIMUM 4 ” DUCT AND NO LONGER THAN 70 ’ OF FLEX DUCT. SUBTRACT 15 ’ OF ALLOWED LENGTH <br />FOR EACH ELBOW. <br />NOTE ALL KITCHEN RANGE HOODS: <br />MINIMUM 100 CFM FAN TESTED AT A STATIC PRESSURE OF .25 WC AND RATED @ 3 SONES OR LESS REQUIRED TO BE INSTALLED. <br />FAN MUST BE ATTACHED TO A MINIMUM 5 ” SMOOTH DUCT AND NO LONGER THAN 85 ’. SUBTRACT 15’ OF ALLOWED LENGTH FOR <br />EACH ELBOW. <br /> 3/8" = 1'-0"1 Roof Plan <br /> 3/8" = 1'-0"2 Electrical Plan <br />ELECTRIC READY NOTES <br />1.WATER HEATING SYSTEM (WATER HEATER) (SECTION 150.0(N)) <br />A.SYSTEMS USING GAS OR PROPANE WATER HEATERS TO SERVE INDIVIDUAL DWELLING UNITS SHALL DESIGNATE A SPACE AT <br />LEAST 2.5 FEET BY 2.5 FEET WIDE AND 7 FEET TALL SUITABLE FOR THE FUTURE INSTALLATION OF A HEAT PUMP WATER HEATER <br />(HPWH) BY MEETING EITHER A OR B LISTED UNDER SECTION 150.0(N). <br />I.IF THE DESIGNATED SPACE IS WITHIN 3 FEET FROM THE WATER HEATER: <br />A.A DEDICATED 125 VOLT, 20 AMP ELECTRICAL RECEPTACLE THAT IS CONNECTED TO THE ELECTRIC PANEL WITH A 120/240 VOLT 3 <br />CONDUCTOR, 10 AWG COPPER BRANCH CIRCUIT, WITHIN 3 FEET FROM THE WATER HEATER. <br />II. ISOLATE BOTH ENDS OF THE UNUSED CONDUCTOR. <br />B.A RESERVED SINGLE POLE CIRCUIT BREAKER SPACE IN THE ELECTRICAL PANEL ADJACENT TO THE CIRCUIT BREAKER <br />C.A CONDENSATE DRAIN THAT ALLOWS NATURAL DRAINING OF THE WATER HEATER. <br />D.. IF THE DESIGNATED SPACE IS MORE THAN 3 FEET FROM THE WATER HEATER: SEE ADDITIONAL CODE REQUIREMENTS. <br />B.WHEN A SECOND WATER HEATER IS INSTALLED AS PART OF THE ADDITION SHALL COMPLY WITH SECTION (150.2(A)(D). <br />1108 N Towner St & <br />#212/13/2024