STATEMENT OF SPECIAL INSPECTION <br />1.CONTINUOUS AND PERIODIC SPECIAL INSPECTION IS REQUIRED FOR THE <br />WORK AS DESCRIBED IN THE 2022 CALIFORNIA BUILDING CODE CHAPTER 17. <br />SEE INSPECTION SCHEDULE BELOW. ONLY CHECKED ITEMS ARE REQUIRED. <br />2.APPROVAL BY THE INSPECTOR DOES NOT MEAN APPROVAL OF FAILURE TO <br />COMPLY WITH THE PLANS OR SPECIFICATIONS. ANY DETAIL THAT FAILS TO BE <br />CLEAR OR IS AMBIGUOUS MUST BE REFERRED TO THE STRUCTURAL <br />ENGINEER FOR INTERPRETATION OR CLARIFICATION. <br />3.FOR VERIFICATION AND INSPECTION OF SOILS SEE SOILS REPORT. SPECIAL <br />INSPECTIONS MAY BE PERFORMED BY THE PROJECT GEOTECHNICAL <br />ENGINEER. <br />4.CONTINUOUS SPECIAL INSPECTION PER AWS D1.1 IS REQUIRED FOR ALL <br />STRUCTURAL STEEL WELDING, EXCEPT FOR SINGLE PASS FILLET WELDS NOT <br />EXCEEDING 5/16" IN SIZE. WELDING INSPECTORS SHALL BE AWS Q.C.-1 <br />CERTIFIED. <br />5.PERIODIC SPECIAL INSPECTION IS REQUIRED FOR WOOD SHEAR WALLS, <br />SHEAR PANELS, AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, <br />ANCHORING, AND OTHER FASTENING OF COMPONENTS OF THE SEISMIC <br />FORCE RESISTING SYSTEM, INCLUDING WOOD SHEAR WALLS, WOOD <br />DIAPHRAGMS, DRAG STRUTS, BRACES, SHEAR PANELS, AND HOLDOWNS. <br />EXCEPTION: SPECIAL INSPECTION IS NOT REQUIRED FOR WOOD SHEAR <br />WALLS, SHEAR PANELS AND DIAPHRAGMS, INCLUDING NAILING, BOLTING, <br />ANCHORING AND OTHER FASTENING TO OTHER COMPONENTS OF THE <br />SEISMIC-FORCE-RESISTING SYSTEM WHERE FASTENER SPACING OF THE <br />SHEATHING IS MORE THAN 4 INCHES ON CENTER (O.C.). INSPECTIONS SHALL <br />BE PERFORMED BEFORE COVERING. <br />6.CONTRACTORS RESPONSIBLE FOR CONSTRUCTION OF A WIND OR SEISMIC <br />FORCE RESISTING SYSTEM/COMPONENT LISTED IN THIS STATEMENT OF <br />SPECIAL INSPECTION SHALL SUBMIT A WRITTEN STATEMENT OF <br />RESPONSIBILITY TO THE BUILDING AND SAFETY INSPECTORS AND THE <br />OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH A SYSTEM OR <br />COMPONENT PER SEC 1704.4. <br />7.WHERE FABRICATION OF MEMBERS AND ASSEMBLIES IS PERFORMED ON THE <br />PREMISES OF A FABRICATOR'S SHOP, SPECIAL INSPECTION OF THE <br />FABRICATED ITEMS SHALL BE REQUIRED BY THIS SECTION, UNLESS THE <br />FABRICATOR IS REGISTERED AND APPROVED TO PERFORM SUCH WORK <br />WITHOUT SPECIAL INSPECTION. APPROVAL SHALL BE BASED UPON REVIEW <br />OF THE FABRICATOR'S WRITTEN PROCEDURAL AND QUALITY CONTROL <br />MANUALS AND PERIODIC AUDITING OF FABRICATION PRACTICES BY AN <br />APPROVED SPECIAL INSPECTION AGENCY. AT COMPLETION OF FABRICATION, <br />THE APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE <br />TO THE BUILDING OFFICIAL STATING THAT THE WORK WAS PERFORMED IN <br />ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. <br />CONTRACTOR SHALL BE RESPONSIBLE OF VERIFYING APPROVAL OF <br />FABRICATOR. <br />8.CONTINUOUS SPECIAL INSPECTION BY A REGISTERED DEPUTY INSPECTOR IS <br />REQUIRED FOR FIELD WELDING, POST-INSTALLED ADHESIVE ANCHORS <br />INSTALLED HORIZONTALLY OR UPWARDLY INCLINED TO RESIST SUSTAINED <br />TENSION LOADS, SHOTCRETE PLACEMENT, CONCRETE WITH f'c > 2,500 PSI, <br />SPRAYED-ON FIREPROOFING, ENGINEERED MASONRY, HIGH-LIFT GROUTING, <br />HIGH LOAD DIAPHRAGMS, SPECIAL MOMENT RESISTING CONCRETE FRAMES, <br />AND HELICAL PILE FOUNDATIONS. <br />GENERAL <br />1.ALL NEW CONSTRUCTION SHALL COMPLY WITH THE CONTRACT DOCUMENTS <br />AND THE 2022 CALIFORNIA BUILDING CODE. <br />2.REFERENCE TO CODES, RULES, REGULATIONS, STANDARDS, <br />MANUFACTURER'S INSTRUCTIONS OR REQUIREMENTS OF REGULATORY <br />AGENCIES ARE TO THE LATEST PRINTED EDITION OF EACH IN EFFECT AT THE <br />DATE OF SUBMISSION OF BID UNLESS THE DOCUMENT DATE IS SHOWN. <br />3.TYPICAL DETAILS AND GENERAL NOTES APPLY TO ALL PARTS OF THE WORK <br />EXCEPT WHERE SPECIFICALLY DETAILED OR UNLESS NOTED OTHERWISE <br />(U.N.O.) <br />4.THE STRUCTURAL DRAWINGS ILLUSTRATE THE NEW STRUCTURAL MEMBERS. <br />REFER TO ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR <br />NON-STRUCTURAL ITEMS WHICH REQUIRE SPECIAL PROVISIONS DURING THE <br />CONSTRUCTION OF THE STRUCTURAL MEMBERS. <br />5.REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR DEPRESSIONS, EDGE OF <br />SLAB, OPENINGS, SLOPES, DRAINS, CURBS, PADS, EMBEDDED ITEMS, <br />NON-BEARING PARTITIONS, ETC. REFER TO MECHANICAL AND ELECTRICAL <br />DRAWINGS FOR SLEEVES, OPENINGS, AND HANGERS FOR PIPES, DUCTS AND <br />EQUIPMENT. <br />6.DRAWING DIMENSIONS ARE TO FACE OF STRUCTURE, JOINT CENTERLINE OR <br />COLUMN GRID CENTERLINE UNLESS NOTED OTHERWISE. DO NOT SCALE THE <br />DRAWINGS. <br />7.THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR COORDINATING <br />THE WORK OF ALL TRADES AND SHALL VERIFY ALL DIMENSIONS AND <br />CONDITIONS WHICH IMPACT THE WORK, FIELD VERIFY SIZES, ELEVATIONS, <br />HOLE LOCATIONS, ETC. PRIOR TO FABRICATION. THE LANGUAGE "BY OTHERS" <br />USED IN THIS STRUCTURAL DRAWING SET INDICATES ELEMENTS OR PARTS <br />OF WORK NOT WITHIN GCA SCOPE AND SHOWN OR REFERENCED FOR EASE <br />OF COORDINATION ONLY. SUCH LANGUAGE SHALL NOT IMPLY THAT SUCH <br />ELEMENTS OR PARTS OF WORK ARE EXCLUDED FROM THE CONTRACTOR'S <br />SCOPE OF WORK. <br />8.CONTRACTOR SHALL CAREFULLY REVIEW THE DRAWINGS TO IDENTIFY THE <br />SCOPE OF WORK REQUIRED, VISIT THE SITE TO RELATE THE SCOPE OF WORK <br />TO EXISTING CONDITIONS AND DETERMINE THE EXTENT TO WHICH THOSE <br />CONDITIONS AND PHYSICAL SURROUNDINGS WILL IMPACT THE WORK. <br />9.EXISTING CONDITIONS AS SHOWN ON THESE PLANS ARE FOR REFERENCE <br />ONLY. CONTRACTOR IS REQUIRED TO FIELD VERIFY ALL EXISTING <br />CONDITIONS PRIOR TO CONSTRUCTION. CONTRACTOR SHALL REPORT <br />CONDITIONS THAT CONFLICT WITH THE CONTRACT DOCUMENTS TO THE <br />OWNER'S REPRESENTATIVE. DO NOT DEVIATE FROM THE CONTRACT <br />DOCUMENTS WITHOUT WRITTEN DIRECTION FROM THE OWNER'S <br />REPRESENTATIVE. <br />10.THE CONTRACTOR SHALL RESOLVE ANY CONFLICTS ON THE DRAWINGS OR IN <br />THE SPECIFICATIONS WITH THE OWNER'S REPRESENTATIVE BEFORE <br />PROCEEDING WITH THE WORK. <br />11.NO DEVIATION, MODIFICATION & SUBSTITUTION FROM THE APPROVED SET OF <br />STRUCTURAL DRAWINGS SHALL BE MADE WITHOUT WRITTEN APPROVAL <br />FROM THE OWNER / OWNER'S REPRESENTATIVE, THE ENGINEER OF RECORD, <br />AND THE PROJECT ARCHITECT. <br />12.THE CONTRACTOR SHALL PROVIDE ALL NECESSARY CONCRETE FORMWORK <br />SHORING/RE-SHORING, EXCAVATION SHORING, DEMOLITION SHORING, <br />BRACES, GUYS, HOIST BEAMS, ETC., REQUIRED TO SUPPORT ANY AND ALL <br />LOADS THE BUILDING STRUCTURE AND COMPONENTS, EARTHWORK, OTHER <br />STRUCTURES, AND UTILITIES ARE SUBJECTED TO DURING CONSTRUCTION. <br />CONCRETE FORMWORK/CONCRETE RE-SHORING, DEMOLITION, AND <br />EXCAVATION SHORING SYSTEMS MUST BE DESIGNED AND STAMPED BY A <br />CIVIL OR STRUCTURAL ENGINEER LICENSED BY THE LOCAL JURISDICTION <br />AND RETAINED BY THE CONTRACTOR. VISITS TO THE SITE BY GCA DOES NOT <br />INCLUDE OBSERVATION OF THE ABOVE NOTED ITEMS. <br />13.THE CONTRACTOR SHALL PROVIDE MEANS, METHOD, TECHNIQUES, <br />SEQUENCE AND PROCEDURE OF CONSTRUCTION AS REQUIRED. SITE VISITS <br />PERFORMED BY GCA DO NOT INCLUDE INSPECTIONS OF MEANS AND <br />METHODS OF CONSTRUCTION PERFORMED BY THE CONTRACTOR. <br />14.THE CONTRACTOR SHALL PROTECT ALL WORK, MATERIALS AND EQUIPMENT <br />FROM DAMAGE AND SHALL PROVIDE PROPER STORAGE FACILITIES FOR <br />MATERIALS AND EQUIPMENT DURING CONSTRUCTION. <br />15.A COPY OF ANY REQUIRED RESEARCH REPORTS AND/OR CONDITIONS OF <br />LISTING SHALL BE MADE AVAILABLE AT THE JOB SITE. <br />16.ATTACHMENT OF NON-STRUCTURAL COMPONENTS SPECIFIED BY OTHERS TO <br />STRUCTURAL ELEMENTS SHALL BE SPECIFIED BY THE NON-STRUCTURAL <br />COMPONENT DESIGNER/SPECIFIER/INSTALLER. DESIGNER OF <br />NON-STRUCTURAL ELEMENTS SHALL AT A MINIMUM SPECIFY THE <br />CONNECTION TO THE STRUCTURE INCLUDING BUT NOT LIMITED TO: <br />CONNECTING HARDWARE, WIRE, HANGERS, FASTENERS, CLIPS, UNISTRUT <br />MEMBERS, ETC. NON STRUCTURAL ELEMENTS SHALL INCLUDE, BUT NOT <br />LIMITED TO: MEP AND HVAC EQUIPMENT & THEIR SUPPORTING PADS, <br />PLATFORMS, FRAMES, ETC.; DUCTWORK, PIPES, CONDUITS, ARTWORK, <br />GRILLES, GRATING, METAL SCREENS, ELEVATOR RAILS, STONE FINISH TILES, <br />STONE CAPS, BRICK VENEER. <br />17.SPECIFICATIONS RELATED TO WATERPROOFING, INCLUDING BUT NOT LIMITED <br />TO MEMBRANES, WATERSTOPS, SEALANTS, FLASHING, VAPOR BARRIERS, ARE <br />EXCLUDED FROM GCA SCOPE. <br />18.ALLOW 10 BUSINESS DAYS FOR PROCESSING SHOP DRAWINGS AND <br />SUBMITTALS AFTER RECEIPT. ALLOW 5 BUSINESS DAYS FOR RESPONDING TO <br />REQUESTS FOR INFORMATION (RFI'S). <br />CODE <br />1.BUILDING SHALL COMPLY WITH THE 2022 CALIFORNIA BUILDING CODE. <br />2.VERTICAL LIVE LOADS: <br />A.MEZZANINE 18PSF DEAD / 75 PSF LIVE (RETAIL/PRODUCTION) <br />TIMBER <br />1.PROVIDE GRADE-MARKED DOUGLAS FIR STRUCTURAL LUMBER COMPLYING <br />WITH STANDARD GRADING RULE NUMBER 17 OF THE WEST COAST LUMBER <br />INSPECTION BUREAU. REGARDLESS OF THE MOISTURE CONTENT AT THE TIME <br />OF MANUFACTURE, THE MOISTURE CONTENT UNDER SERVICE CONDITION AT <br />THE TIME OF ENCLOSURE OF THE STRUCTURAL MEMBERS SHALL BE: <br />A.19% EXCEPT AS NOTED BELOW <br />B.15% FOR WOOD JOISTS AND BEAMS WITH MORE THAN 2 FRAMED LEVELS <br />ABOVE THEM <br />"S-DRY" LUMBER AND "MC15" LUMBER ARE RECOMMENDED FOR CASES "A" <br />AND "B" ABOVE RESPECTIVELY. <br />ALTERNATIVELY, LUMBER WITH HIGHER MOISTURE CONTENT AT THE TIME OF <br />MANUFACTURE THAN THE VALUES SHOWN ABOVE MAY BE UTILIZED IF <br />APPROVED IN WRITING BY THE OWNER. IN SUCH CASE, CONTRACTOR SHALL <br />INFORM THE OWNER AND ADVISE IF VOLUMETRIC CHANGES SUCH AS <br />WARPING, BENDING, TWISTING, ETC. ARE EXPECTED AND HOW THESE MAY <br />AFFECT THE QUALITY OF CONSTRUCTION. <br />2.ALL LUMBER SHALL BE STRESS GRADED DOUGLAS FIR NO. 2, UNLESS NOTED <br />OTHERWISE. ALL 4x10 BEAMS OR LARGER AND 6x8 BEAMS OR LARGER SHALL <br />BE DOUGLAS FIR NO. 1. <br />3.ALL LUMBER IN DIRECT CONTACT WITH CONCRETE OR MASONRY, INCLUDING <br />BUT NOT LIMITED TO FOUNDATION SILLS, SHALL BE NATURALLY DURABLE OR <br />PRESERVATIVE-TREATED DOUGLAS FIR. <br />4.WOOD STRUCTURAL PANELS SHALL COMPLY WITH U.S. PRODUCT STANDARDS <br />FOR ITS TYPE IN PS 1-09 OR PS 2-10 AND BE CLASSIFIED AS EXPOSURE 1. AS A <br />MINIMUM ALL WOOD STRUCTURAL PANELS SHALL BE APA RATED SHEATHING <br />UNLESS NOTED OTHERWISE ON PLANS AND DETAILS. PANEL CONSTRUCTION <br />FOR ALL WOOD STRUCTURAL PANELS SHALL BE 5 PLY PLYWOOD, EXCEPT <br />THAT OSB IS PERMITTED FOR WALL SHEATHING AT NON FIRE TREATED <br />PANELS. MINIMUM GRADE VENEER FOR PLYWOOD SHALL BE "CD". ALL WOOD <br />STRUCTURAL PANELS SHALL BE BLOCKED AT UNSUPPORTED EDGES. WALL <br />PANELS SHALL BE 15/32 INCH, PANEL INDEX (P.I.) 32/16 U.N.O. ALL WOOD <br />STRUCTURAL PANELS MUST BE INSTALLED WITH FACE GRAIN <br />PERPENDICULAR TO SUPPORTS. <br />5.NAILS: <br />A.ALL NAILS SHALL BE COMMON WIRE NAILS IN ACCORDANCE WITH THE <br />LATEST EDITION OF THE "NATION DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION" (NDS) <br />B.NAILING TO BE IN ACCORDANCE WITH CBC 2022 NAILING SCHEDULE <br />UNLESS NOTED OTHERWISE. <br />C.THE MINIMUM PENETRATION OF NAILS SHALL BE 10 TIMES THE NAIL SHANK <br />DIAMETER OR 1 12", WHICHEVER IS GREATER. PENETRATION IS MEASURED <br />INTO THE PIECE RECEIVING THE NAIL POINT. <br />D.BORED HOLES SHALL BE PERMITTED FOR ALL NAILS TO HELP PREVENT <br />WOOD FROM SPLITTING. BORE HOLES SHALL BE MANDATORY FOR 20d <br />NAILS OR LARGER. WHEN UTILIZED, BORED HOLES SHALL HAVE DIAMETER <br />NOT EXCEEDING 75% OF NAIL DIAMETER. <br />E.EDGE DISTANCES, END DISTANCES, AND FASTENER SPACING SHALL BE <br />SUFFICIENT TO PREVENT SPLITTING OF THE WOOD. BORED HOLES MAY BE <br />UTILIZED TO HELP PREVENT WOOD FROM SPLITTING. <br />F.ALL NAILS SHALL BE GALVANIZED WHEN EXPOSED TO WEATHER. <br />G.ALL DIAPHRAGM AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS <br />OR GALVANIZED BOX. <br />6.WOOD SCREWS: <br />D.WOOD SCREWS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF <br />"NATION DESIGN SPECIFICATION FOR WOOD CONSTRUCTION" (NDS). <br />E.THE MINIMUM PENETRATION OF WOOD SCREWS SHALL BE 10 TIMES THE <br />SCREW DIAMETER OR 1 12", WHICHEVER IS GREATER. PENETRATION IS <br />MEASURED INTO THE PIECE RECEIVING THE NAIL POINT. <br />F.LEAD HOLES SHALL BE ABOUT 7 8 THE DIAMETER OF THE SCREW. <br />G.WOOD SCREWS SHALL BE TURNED, NOT DRIVEN, INTO LEAD HOLES. SOAP <br />OR OTHER LUBRICANTS SHALL BE PERMITTED AS NEEDED TO FACILITATE <br />THE INSERTION AND PREVENT DAMAGE OF THE WOOD SCREW. <br />H.EDGE DISTANCES, END DISTANCES, AND FASTENER SPACING SHALL BE <br />SUFFICIENT TO PREVENT SPLITTING OF THE WOOD. <br />D.ALL WOOD SCREWS SHALL BE GALVANIZED WHEN EXPOSED TO WEATHER. <br />7.LAG SCREWS SHALL BE TURNED, NOT DRIVEN, INTO PRE DRILLED HOLES. <br />PROVIDE LEAD HOLE 40% TO 70% OF THREADED SHANK DIAMETER AND FULL <br />DIAMETER FOR SMOOTH SHANK PORTION. <br />8.ALL FRAMING HARDWARE SHALL BE STRONG-TIE CONNECTORS AS <br />MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, UNLESS NOTED <br />OTHERWISE. INSTALL PER MANUFACTURER'S RECOMMENDATIONS AND ICC <br />REQUIREMENTS. ALL BOLTS IN HOLD-DOWN ANCHORS SHALL BE TORQUED <br />PER MANUFACTURERS REQUIREMENTS. <br />9.INSTALL HOLD DOWNS 12 INCH MINIMUM ABOVE THE PLATE TO ALLOW FOR <br />TIGHTENING ANCHOR BOLT. THE HOLD DOWN SHALL BE INSTALLED TIGHT TO <br />THE POST WITHOUT FILLERS OR DAPPING. DO NOT BEND HOLD DOWN <br />ANCHORS. HOLD DOWN HARDWARE SHALL BE IN PLACE PRIOR TO <br />FOUNDATION INSPECTION. HOLD DOWN SHALL BE FINGER TIGHT AND 1 <br />2 <br />WRENCH TURN JUST PRIOR TO COVERING THE WALL FRAMING. UPPER FLOOR <br />HOLD DOWNS SHALL BE CONTINUED TO THE FOUNDATION PER TYPICAL <br />DETAILS. <br />10.ALL BOLTS AND ANCHOR BOLTS IN WOOD SHALL BE A-307 STANDARD BOLTS. <br />HOLES SHALL BE AT LEAST 132" BUT NOT MORE THAN 116" LARGER THAN THE <br />BOLT DIAMETER. A STANDARD CUT WASHER (NATIONAL DESIGN <br />SPECIFICATIONS FOR WOOD CONSTRUCTION - APPENDIX TABLE L6), OR <br />METAL PLATE OR METAL STRAP OF EQUAL OR GREATER DIMENSIONS AND <br />THICKNESS SHALL BE PROVIDED BETWEEN THE WOOD AND THE NUT. <br />11.DO NOT CUT, BORE, COUNTERSINK OR NOTCH WOOD MEMBERS EXCEPT <br />WHERE SHOWN IN THE DETAILS. <br />12.PROVIDE DOUBLE JOISTS BENEATH ALL PARALLEL WALLS. PROVIDE SOLID <br />BLOCKING BENEATH ALL WALLS PERPENDICULAR TO JOISTS. <br />13.JOISTS OR RAFTERS FRAMING FROM OPPOSITE SIDES OF BEAMS OR WALLS <br />SHALL HAVE A LAP OF 4" OR MORE AND BE SPLICED WITH 4-16D NAILS, <br />UNLESS NOTED OTHERWISE. <br />14.ENGINEERED LUMBER <br />A.I-JOIST MEMBERS SHALL BE "TJI" JOISTS MANUFACTURED BY <br />"WEYERHAEUSER" (ICC-ESR 1153, L.A. RR 25538). EQUIVALENT I-JOISTS <br />MANUFACTURED BY "ROSEBURG" WILL BE ALLOWED (ICC-ESR 1251, LARR <br />25439). <br />B.LSL MEMBERS SHALL BE "TIMBERSTRAND" LSL MANUFACTURED BY <br />"WEYERHAEUSER" (ICC-ESR1387, COLA RR25202). LSL SHALL BE GRADE <br />1.55E. <br />C.LVL MEMBERS SHALL BE "RIGIDLAM" LVL MANUFACTURED BY ROSEBURG <br />(ICC-ESR 1210, COLA RR#25680) GRADE 2.1E. <br />D."RIGIDRIM" SHALL BE MANUFACTURED BY "ROSEBURG" (ICC-ESR 1210, <br />COLA RR#25680) <br />E.PROVIDE CAMBER WHERE INDICATED ON DRAWINGS <br />F.ALL JOISTS & BEAMS SHALL BE MANUFACTURED BY A LICENSED <br />FABRICATOR. <br />15.HOT DIP GALVANIZED FASTENERS SUCH AS - BUT NOT LIMITED TO - NAILS, <br />SCREWS, BOLTS, THREADED ROD, ETC., SHALL BE USED WHEN IN CONTACT <br />WITH PRESERVATIVE OR FIRE RETARDANT TREATED LUMBER. EXCEPTION: <br />PLAIN CARBON STEEL FASTENERS IN SBX/DOT AND ZINC BORATE <br />PRESERVATIVE-TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT SHALL <br />BE PERMITTED. <br />16.FRAMING CLIPS TO COMPLY WITH (IAPMO ER 0112 2606, L.A. RR 25814). <br />STRAPS TO COMPLY WITH (ICC-ESR 2105, L.A. RR 25713). <br />17.NARROW STEEL SHEAR PANELS SHALL BE INSTALLED PER THE <br />MANUFACTURERS RECOMMENDATIONS AND CONFORM TO THE FOLLOWING: <br />HARDY FRAMES (HFX): LARR#25759 SIMPSON STRONG WALLS (SSW): <br />LARR#25625 <br />18.WOOD NAILERS: U.N.O. ON PLANS AND DETAILS, WHERE WOOD MEMBERS ARE <br />TO BE CONNECTED TO STEEL ELEMENTS, OR WHERE WOOD NAILERS <br />CONNECTED TO STEEL MEMBERS ARE NEEDED FOR PROPER INSTALLATION <br />OF FINISH MATERIALS, AS A MINIMUM PROVIDE WOOD NAILERS AS SPECIFIED <br />BELOW WITH |5"|Q WELDED THREADED STUDS @ 24" O.C: <br />A.WOOD NAILERS NEEDED ONLY FOR INSTALLATION OF FINISH MATERIAL: 2x <br />WOOD NAILERS. COUNTERSINKING OF THREADED STUDS BOLT IS <br />ACCEPTABLE IF NEEDED FOR FLUSH INSTALLATION OF FINISH MATERIAL. <br />B.WOOD NAILERS NEEDED TO SUPPORT OTHER WOOD ELEMENTS: 2x WOOD <br />NAILERS OR 3x WOOD NAILERS WITH OR WITHOUT COUNTERSINKING OF <br />THREADED STUDS BOLT RESPECTIVELY. <br />19.GLUE BETWEEN WOOD STRUCTURAL PANELS AND WOOD FRAMING MEMBERS <br />SHALL BE APPLIED TO REDUCE SQUEAKINESS OF OCCUPIABLE SPACES. GLUE <br />SHALL CONFORM TO APA PERFORMANCE SPECIFICATION AFG-01 OR ASTM <br />D3498. INSTALL AS DIRECTED PER APA FORM NO. Q300P. <br />20.WOOD AND COMPONENTS IN EXTERIOR WALLS LABELED AS FIRE RATED BY <br />THE ARCHITECT SHALL BEAR A FIRE-RETARDANT-TREATED STAMP INDICATION <br />BY MEANS SATISFACTORY TO LOCAL AUTHORITIES. THE FOLLOWING FIRE <br />RETARDANTS MAY BE USED: <br />A.FOR PLYWOOD AND LUMBER: D-BLAZE FIRE RETARDANT (ICC ESR-2645). <br />EQUIVALENT SUBSTITUTE MAY BE USED ONLY IF PRODUCT IS APPROVED <br />BY THE EOR. <br />TYPE OF WORK <br />INSPECTION SCHEDULE <br />CODE REFERENCE <br />CONCRETE WORK CBC TABLE 1705.3 <br />STRUCTURAL STEEL <br />STRUCT. STL. WELDING <br />HIGH STRENGTH BOLTS <br />MASONRY WORK <br />HIGH LOAD DIAPH. <br />REMARKS <br />STRUCTURAL WOOD <br />COLD FORMED STEEL <br />SEE NOTE ABOVE <br />CBC TABLE 1705.7DRIVEN DEEP FOUND. <br />C.I.P. DEEP FOUND.CBC TABLE 1705.8 <br />CBC 1705.2 <br />CBC 1705.4 <br />SHOTCRETE WORK <br />REINFORCING STEEL <br />CBC 1705.5.1 <br />CBC 1704.2.5 & 1705.11.1 <br />CBC 1705.2.2 & 1705.11.2 <br />SOIL CONDITION CBC TABLE 1705.6 <br />SEE ALSO ICC APPROVAL <br />SEE SOILS REPORT <br />POST INSTALL ANCHOR <br />CBC TABLE 1705.3 <br />CBC TABLE 1705.3 <br />CBC TABLE 1705.3 <br />CBC 1705.2 <br />CBC 1705.2 <br />GENERAL NOTES <br />S-0.1 <br />N.T.S. <br />GN.DWG <br />ABBREVIATIONS <br />A.B.ANCHOR BOLTS <br />ARCH.ARCHITECT OR ARCHITECTURAL <br />B.N.BOUNDARY NAILING <br />BLK'G BLOCKING <br />BM BEAM <br />CF COLD FORMED <br />CONN.CONNECTION <br />CONT.CONTINUOUS <br />DF-L DOUGLAS FIR-LARCH <br />DWG'S DRAWINGS <br />E.N.EDGE NAILING <br />EA.EACH <br />E.O.R.ENGINEER OF RECORD <br />F.N.FIELD NAILING <br />FTG.FOOTING <br />G.C.GENERAL CONTRACTOR <br />GL GRID LINE <br />GLB GLULAM BEAM <br />L.W.LIGHT WEIGHT <br />L.G.LIGHT GAUGE <br />M.B.MACHINE BOLTS <br />MAX.MAXIMUM <br />MIN.MINIMUM <br />O.C.ON CENTER <br />P.T.PRESSURE OR PRESERVATIVE TREADED <br />PL PLATE/PROPERTY LINE <br />PLYWD PLYWOOD <br />PSL PARALLEL STRAND LUMBER <br />RBS REDUCED BEAM SECTION <br />REINF.REINFORCEMENT <br />REQ'D REQUIRED <br />S.A.D.SEE ARCHITECTURAL DRAWINGS <br />S.O.G.SLAB ON GRADE <br />SCHED.SCHEDULE <br />SHT'G SHEATHING <br />SIM.SIMILAR <br />SMS SHEET METAL SCREWS <br />STAGG.STAGGERED <br />T&B TOP AND BOTTOM <br />T&G TONGUE AND GROOVE <br />TYP.TYPICAL <br />U.N.O.UNLESS NOTED OTHERWISE <br />V.I.F.VERIFY IN FIELD <br />WD WOOD <br />W.N.S.WELDED NELSON STUDS <br />W.T.S.WELDED THREADED STUDS <br />SEE SOILS REPORT <br />SEE SOILS REPORT <br />1 <br />1 <br />1 <br />© <br />C <br />O <br />P <br />Y <br />R <br />I <br />G <br />H <br />T <br /> <br />2 <br />0 <br />2 <br />1 <br />, <br /> <br />G <br />A <br />R <br />C <br />I <br />A <br /> <br />C <br />A <br />S <br />T <br />R <br />O <br /> <br />& <br /> <br />A <br />S <br />S <br />O <br />C <br />I <br />A <br />T <br />E <br />S <br /> <br />I <br />N <br />C <br /> <br />( <br />" <br />G <br />C <br />A <br />" <br />) <br />, <br /> <br />7 <br />5 <br />0 <br /> <br />O <br />T <br />A <br />Y <br /> <br />L <br />A <br />K <br />E <br />S <br /> <br />R <br />D <br /> <br /># <br />2 <br />0 <br />2 <br />, <br /> <br />C <br />H <br />U <br />L <br />A <br /> <br />V <br />I <br />S <br />T <br />A <br /> <br />C <br />A <br /> <br />9 <br />1 <br />9 <br />1 <br />0 <br /> <br />/ <br /> <br />A <br />L <br />L <br /> <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />N <br /> <br />D <br />O <br />C <br />U <br />M <br />E <br />N <br />T <br />S <br /> <br />S <br />H <br />A <br />L <br />L <br /> <br />R <br />E <br />M <br />A <br />I <br />N <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />O <br />F <br /> <br />G <br />C <br />A <br />. <br /> <br />A <br />L <br />L <br /> <br />U <br />N <br />A <br />U <br />T <br />H <br />O <br />R <br />I <br />Z <br />E <br />D <br /> <br />U <br />S <br />E <br />, <br /> <br />M <br />O <br />D <br />I <br />F <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br /> <br />O <br />R <br /> <br />R <br />E <br />P <br />R <br />O <br />D <br />U <br />C <br />T <br />I <br />O <br />N <br /> <br />I <br />S <br /> <br />P <br />R <br />O <br />H <br />I <br />B <br />I <br />T <br />E <br />D <br />. <br /> <br />G <br />C <br />A <br /> <br />S <br />H <br />A <br />L <br />L <br /> <br />R <br />E <br />T <br />A <br />I <br />N <br /> <br />A <br />L <br />L <br /> <br />R <br />I <br />G <br />H <br />T <br />S <br /> <br />T <br />O <br /> <br />I <br />N <br />T <br />E <br />L <br />L <br />E <br />C <br />T <br />U <br />A <br />L <br /> <br />P <br />R <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />C <br />O <br />N <br />T <br />A <br />I <br />N <br />E <br />D <br /> <br />H <br />E <br />R <br />E <br />I <br />N <br />. <br />ISSUE DATE: <br />ISSUE NO.: <br />STAMP: <br />EXPIRATION DATE: 3/31/2026 <br />PROJECT NAME: <br />CONSULTANTS <br />PROJECT ADDRESS: <br />OWNER: <br />PROJECT NO.: <br />CAD DWG FILE: <br />DRAWN BY: <br />CHECKED BY: <br />SHEET TITLE: <br />SHEET SCALE: <br />ISSUE <br />IGC <br />IGC <br />750 Otay Lakes Rd #202 <br />Chula Vista, CA 91910 <br />e: garciacastro.se@gmail.com <br />www.gcastructural.com <br />DATE <br />10/18/2024 <br />HARBOR BUSINESS <br />PARK <br />3625 MACARTHUR BLVD <br />SUITE 307-308 <br />SANTA ANA, CA <br />LANDLORD <br />IMPROVEMENT <br />2416.2 <br />CDL DESIGN GROUP <br />12 MAUCHLY, SUITE E <br />IRVINE, CA <br />PC RESUBMITTAL <br />PC SUBMITTAL <br />2 <br />7/9/2024 <br />PC RESUBMITTAL9/20/2024 <br />2 <br />3625 W MacArthur Blvd <br />#30712/9/2024