My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2309 N Spurgeon St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Spurgeon St
>
2309 N Spurgeon St
>
2309 N Spurgeon St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2025 2:51:20 PM
Creation date
6/6/2025 1:20:08 PM
Metadata
Fields
Template:
Plan
Permit Number
20184262
Full Address
2309 N Spurgeon St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
GENERAL NOTES <br />PHOTOVOLTAIC NOTES <br />AERIAL VIEW <br />VICINITY MAP <br />PV-0 <br />COVER PAGE <br />PROJECT DESCRIPTION:SCOPE:SCOPE: <br />DATE:11/19/2024 <br />SCALE:AS NOTED PAPER SIZE:17"x11" <br />CUSTOMER INFORMATION <br />BUILDING INFO: <br />OMAR NASSER <br />NAME: DOUG RISK <br />ADDRESS: 2309 NORTH SPURGEON <br />STREET, SANTA ANA, CA 92706 <br />CITY OF SANTA ANA <br />UTILITY: SCE <br />COMPANY NAME: TREEPUBLIC <br />LICENSE:# 996593 <br />ADDRESS: 3521 JACK NORTHROP AVE, <br />HAWTHORNE CA 90250 <br />PHONE: (800) 701-8073 <br />6.56 KW DC Roof Mounted <br />PV Electrical System <br />16 - Solarever 410W PV Modules <br />1 - Tigo 11.4KW Inverter <br />2 - Tesla Powerwall 3 Battery <br />TWO STORY BUILDING <br />ROOF TYPE: COMPOSITION SHINGLE <br />ROOF STRUCTURE: <br />2''X4'' TRUSSES 24'' O/C <br />CONSTRUCTION TYPE:V-B <br />OCCUPANCY GROUP: R3 <br />FIRE SPRINKLERS: NO <br />MOUNTING SYSTEM: <br />IRONRIDGE RACKING <br />PARCEL NUMBER: 00307232 <br />LOT AREA: 6,000 SQFT <br />LIVING AREA: 2,614 SQFT <br />SOLAR MODULES: <br /> NEW <br />SYSTEM SIZE: <br /> DC STC: 6.56 kW <br /> AC CEC: 5.93 kW <br />INVERTERS OUTPUT: AC: 11.40 kW <br />1. ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED AND IDENTIFIED UL 1703. <br />2. SOLAR SYSTEM SHALL NOT COVER ANY PLUMBING OR MECHANICAL VENTS. <br />3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED. <br />4. SOLAR INVERTER MUST HAVE A MANUFACTURE INSTALLED DISCONNECTING MEANS THAT PREVENTS PARALLEL FEEDING UTILITY LINES DURING POWER OUTAGE. <br />5. REMOVAL OF AN INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE <br />PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTORS. <br />6. ALL PV MODULES AND ASSOCIATED EQUIPMENT AND WIRING SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. <br />7. LIVE PARTS OF PV SOURCE CIRCUITS AND PV OUTPUT CIRCUITS OVER 150V TO GROUND SHALL NOT BE ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS WHILE ENERGIZED. <br />8. INVERTER IS EQUIPPED W/ INTEGRATED GFDI, THUS PROVIDING GROUND FAULT PROTECTION. <br />9. ALL CONDUCTORS SHALL BE COPPER AND 90 DEG RATED. <br />10. ALL ELECTRICAL EQUIPMENT SHALL BE LISTED BY A RECOGNIZED ELECTRICAL TESTING LABORATORY OR APPROVED BY THE DEPARTMENT. <br />11. CONDUITS SHOULD BE PAINTED TO MATCH EXISTING ROOF AND WALL COLORS. <br />12. ALL WORK SHALL BE IN ACCORD WITH THE 2022 CBC, 2022 CEC AND 2022 NEC WITH SPECIAL EMPHASIS ON ARTICLE 690. <br />13. THE OUTPUT OF A UTILITY INTERACTIVE-INVERTER SHALL BE PERMITTED TO BE CONNECTED TO THE SUPPLY SIDE OF THE SERVICE DISCONNECTING MEANS AS PER 230.82(6). <br />14. A SINGLE CONDUCTOR SHALL BE PERMITTED TO BE USED TO PERFORM THE MULTIPLE FUNCTIONS OF DC GROUNDING, AC GROUNDING AND BONDING BETWEEN AC AND DC SYSTEMS <br />SIZED AS PER SEC 250.122 <br />15. EQUIPMENT GROUND CONDUCTOR REQUIRED IN RACEWAYS SIZED PER CEC 250-122. <br />16. PER ART NON-CURRENT CARRYING METAL PARTS OF EQUIPMENT SHALL BE EFFECTIVELY BONDED TOGETHER. <br />SHEET INDEX <br />PV-2 <br />PV-3 <br />PV-4 <br />D-1 <br />D-2 <br />D-3 <br />D-4 <br />D-5 <br />D-6 <br />D-7 <br />SITE PLAN <br />THREE LINE DIAGRAM <br />DESCRIPTION <br />PV-0 COVER PAGE <br />PV-1 <br />NOTES: <br />ALL ELECTRICAL WORK TO BE INSTALLED BY A QUALIFIED AND LICENSED <br />ELECTRICAL CONTRACTOR. <br />ALL SOLAR MODULES SHALL BE UL LISTED 1703 & CEC APPROVED. ALL <br />INVERTERS SHALL BE UL LISTED 1741 CERTIFIED & CEC APPROVED. ALL <br />ELECTRICAL COMPONENTS AND MATERIALS SHALL BE LISTED FOR IT'S <br />PURPOSE AND INSTALLED IN A WORKMAN LIKE MANNER. ALL OUTDOOR <br />EQUIPMENT SHALL MEET APPROPRIATE NEMA STANDARDS. <br />THE ELECTRICAL CONTRACTOR IS ADVISED THAT ALL DRAWINGS AND <br />COMPONENT MANUALS ARE TO BE UNDERSTOOD PRIOR TO INSTALLATION. <br />THE CONTRACTOR IS ADVISED TO HAVE ALL SWITCHES IN THE OFF POSITION <br />AND FUSES REMOVED PRIOR TO INSTALLATION OF FUSE-BEARING <br />COMPONENTS. <br />THIS SYSTEM IS INTENDED TO BE OPERATED IN PARALLEL WITH THE UTILITY <br />SERVICE PROVIDER. ANTI-ISLANDING PROTECTION IS A REQUIREMENT OF UL <br />1741 AND IS INTENDED TO PREVENT THE OPERATION OF THE PV SYSTEM <br />WHEN THE UTILITY GRID IS NOT OPERATIONAL. <br />PERMISSION TO OPERATE THE SYSTEM IS NOT AUTHORIZED UNTIL FINAL <br />INSPECTIONS AND APPROVALS ARE OBTAINED FROM THE LOCAL AUTHORITY <br />HAVING JURISDICTION AND THE LOCAL UTILITY SERVICE PROVIDER. <br />THE METHOD OF ATTACHMENT CREATES A UNIFIED STRUCTURE TO MEET <br />DEAD LOAD, WIND LOAD, AND SEISMIC REQUIREMENTS. SOLAR MODULES <br />WILL BE SECURED TO THE EXISTING ROOF AS SPECIFIED ON THE <br />STRUCTURAL SHEETS. EXISTING ROOF EQUIPMENT WILL NOT BE EFFECTED <br />BY THE PV SYSTEM. ALL STRUCTURAL DESIGN AND INSTALLATION <br />COMPONENTS ARE THE RESPONSIBILITY OF OTHERS AND OUTSIDE THE <br />SCOPE OF THIS DOCUMENT. <br />ALL FASTENERS SHALL BE CORROSION RESISTANT APPROPRIATE FOR SITE <br />CONDITIONS. CONNECTORS SHALL BE TORQUED PER DEVICE LISTING OR <br />ENGINEERING RECOMMENDATIONS. <br />ALL ROOFING REPAIR MUST MAINTAIN EXISTING CLASS AND TYPE OF ROOF <br />AND ALL WORK SHALL BE IN ACCORDANCE WITH THE ROOF IN <br />MANUFACTURER'S INSTALLATION REQUIREMENTS. <br />EXISTING: <br />MSP BUS: <br />MAIN BREAKER: <br />1P, 3W, 120/240V <br />200A <br />200A <br />ELECTRICAL INFORMATION <br />THE FOLLOWING PLANS INCLUDES INSTALLATION OF TWO TESLA POWERWALL 3 LITIUM-ION AC BATTERIES. <br />EACH BATTERY IS SINGLE ASSEMBLY WITH INVERTER. THESE BATTERIES WILL BE INSTALLED OUTSIDE TO <br />EXISTING STUDS AND HAVE A CAPACITY OF 13.5 KWH. WITH TOTAL CAPACITY OF 27.0 KWH <br />POWERWALL 3 MOUNTING DETAILS <br />LOAD CALCULATION BSP <br />SYSTEM CONFIGURATION <br />(2) 11.5 kW TESLA POWERWALL 3 1707000-xx-y (120/240V) <br />(ALL-IN-ONE SOLAR & BATTERY SYSTEM (DC-COUPLED SOLAR)) <br />APPLICABLE CODES <br />2022 CALIFORNIA ELECTRICAL CODE <br />2022 CALIFORNIA BUILDING CODE <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE <br />2022 CALIFORNIA ENERGY CODE <br />2022 CALIFORNIA MECHANICAL CODE <br />2022 CALIFORNIA PLUMBING CODE <br />2022 CALIFORNIA RESIDENTIAL CODE <br />2022 NATIONAL ELECTRICAL CODE <br />2022 CALIFORNIA FIRE CODE <br />ALL OTHER ORDINANCE ADOPTED BY THE <br />LOCAL GOVERNING AGENCIES <br />EQUIPMENT ELEVATION <br />INVERTER & ESS: <br />POWERWALL 3 MOUNTING DETAILS <br />POWERWALL 3 MOUNTING DETAILS <br />NOTE: SMOKE ALARMS AND CARBON MONOXIDE ALARMS SHALL <br />BE PROVIDED FOR THE DWELLING PER CRC R314 AND R315. <br />TESLA GATEWAY DATA SHEET <br />(19) JA SOLAR 395W (JAM54S31-395/MR)EXISTING <br />EXISTING <br />NEW <br />INVERTER: <br />(1) TIGO 11.4KW (TSI-11.4K-US) (120/240V) <br />SOLAR MODULES: (16) SOLAREVER 410W (SE-182*91-410M-108) <br />INVERTER: <br />(1) ABB 3.6KW (PVI-3.6-OUTD-S-US-Z-A) (120/240V) <br />INVERTER & ESS DATA SHEET <br /> EXISTING <br />SYSTEM SIZE: <br /> DC STC: 7.51 kW <br /> AC CEC: 6.73 kW <br />INVERTERS OUTPUT: AC: 3.60 kW <br />NEW <br />NEW <br />ELECTRICAL CALCULATION <br />ATTACHMENT LAYOUT <br />STRUCTURAL DETAIL <br />CODE REQUIRED SIGNAGE <br />PV-5 <br />PV-6 <br />BATTERY REQUIRED SIGNAGEPV-7 <br />PV-8 <br />MODULE DATA SHEET <br />RACKING DATA SHEET <br />ATTACHMENT DATA SHEET <br />GROUNDING SPECS <br />RACKING CERTIFICATION <br />RACKING DETAILS <br />INVERTER DATA SHEET <br />OPTIMIZER DATA SHEET <br />D-8 <br />D-9 <br />D-10 <br />D-11 <br />D-12 <br />D-13 <br />D-14 <br />D-15 <br />RSD DEVICE DATA SHEETD-16 <br />BLDG#101121197 <br />ELEC#20184262 <br />APPROVALS <br />ELEC - MSmith <br />2309 N Spurgeon <br />St12/11/2024
The URL can be used to link to this page
Your browser does not support the video tag.