Laserfiche WebLink
SCOPE:SCOPE: <br />DATE:08/29/2024 <br />SCALE:AS NOTED PAPER SIZE:17"x11" <br />CUSTOMER INFORMATION <br />BUILDING INFO: <br />OMAR NASSER <br />NAME: DOUG RISK <br />ADDRESS: 2309 NORTH SPURGEON <br />STREET, SANTA ANA, CA 92706 <br />CITY OF SANTA ANA <br />UTILITY: SCE <br />COMPANY NAME: TREEPUBLIC <br />LICENSE:# 996593 <br />ADDRESS: 3521 JACK NORTHROP AVE, <br />HAWTHORNE CA 90250 <br />PHONE: (800) 701-8073 <br />6.56 KW DC Roof Mounted <br />PV Electrical System <br />16 - Solarever 410W PV Modules <br />1 - Tigo 11.4KW Inverter <br />2 - Tesla Powerwall 3 Battery <br />TWO STORY BUILDING <br />ROOF TYPE: COMPOSITION SHINGLE <br />ROOF STRUCTURE: <br />2''X4'' TRUSSES 24'' O/C <br />CONSTRUCTION TYPE:V-B <br />OCCUPANCY GROUP: R3 <br />FIRE SPRINKLERS: NO <br />MOUNTING SYSTEM: <br />IRONRIDGE RACKING <br />PARCEL NUMBER: 00307232 <br />LOT AREA: 6,000 SQFT <br />LIVING AREA: 2,614 SQFT <br />D-15 <br />LOAD CALCULATION <br />Standard Method for Dwelling Service Calculations <br />Worksheet for the EVITP Step 7: Article 220.60 – Noncoincident Loads <br />2309 NORTH SPURGEON STREET, SANTA ANA, CA 92706 Air conditioning <br />Step 1: Section 220.12 – Lighting load for listed occupancies.32 A x 240 V x 1 =7,680 VA <br />2,614 Sq.ft x 3 VA =7,842 VA 24 A x 240 V x 1 =5,760 VA <br />Step 2 : Section 220.52 – Small Appliance and Laundry load.0 A x 240 V x 1 =0 VA <br />2,614 Sq.ft x 3 VA =7,842 VA Other Loads <br />2 Appliances Circuits x 1,500 VA =3,000 VA 0 A x 240 V x 1 =0 VA <br />1 Laundry Circuit x 1,500 VA =1,500 VA 0 A x 240 V x 1 =0 VA <br />General Lighting Load =12,342 VA 0 A x 240 V x 1 =0 VA <br />Step 3: Table 220.42 Apply demand factors to the general lighting load.Total Load =13,440 VA <br />First 3,000 VA at 100%=3,000 VA Step 8: 220.50 – 25% of largest motor FLA.* <br />Remainder at 35%9,342 x 0.35 =3270 VA 50 A x 240 V x 25%=3,000 VA <br />Net Load =6270 VA Step 9: 220.14(A) Other Loads – EVSE <br />Step 4: 220.53 – Demand Factor – Appliance Loads – Dwelling Units.50 A x 240 V x 1 =12,000 VA <br />Disposal =1,300 VA Sum of Calculated Loads <br />Dishwasher =1,300 VA Lighting, Sm. Appliance, Laundry (Step 3)=6,270 VA <br />Refrigerator =1,300 VA Fastened in Place Appliances (Step 4)=3,675 VA <br />Microwave =1,000 VA Clothes Dryer (Step 5)=5,000 VA <br />=0 VA Cooking Equipment (Step 6)=0 VA <br />=0 VA Noncoincedent Heat – A/C (Step 7)=13,440 VA <br />=0 VA 25% of Largest Motor (Step 8)=3,000 VA <br />=0 VA Other Loads – (Step 9)=12,000 VA <br />=0 VA Total Calculated Load =43,385 VA <br />Total =4,900 VA Step 10: Table 310.15 (B)(6) – Size the service and conductors. <br />75% of total; four or more appliances =3,675 VA 43,385 VA/240V =180.770 A <br />Step 5: 220.54 – Clothes Dryer – The greater of 5 kW or nameplate value.Conductor Size CU AL <br />5,000 kW Electric Dryer =5,000 VA Step 10: Table 310.15 (B)(6) – Size the service and conductors. <br />Step 6: Table 220.55 -  Household cooking Equipment GEC Size CU AL <br />Oven =0 VA * Remember that although the voltages shown in the tables in <br />Article 430 indicate that motors are rated for 115,230 and 460 Volts, <br />Section 220.5(A) requires nominal voltages of 120, 240 and 480 <br />Volts to be used for load calculations. <br />Range =0 VA <br />=0 VA <br />Total =0 VA <br />2309 N Spurgeon <br />St12/11/2024