GENERAL STRUCTURAL NOTES:ABBREVIATIONS <br />A.B.ANCHOR BOLT <br />ADDL.ADDITIONAL <br />ALT.ALTERNATE <br />A.P.A.AMERICAN PLYWOOD ASSOCIATION <br />ARCH.ARCHITECTURAL <br />A.W.P.A.AMERICAN WOOD PRESERVERS <br />ASSOCIATION <br />B.BOTTOM <br />BLKG.BLOCKING <br />BM.BEAM <br />B.N.BOUNDARY NAIL <br />B.O.F.BOTTOM OF FOOTING <br />BRG.BEARING <br />BTN.BETWEEN <br />BOT. BOTTOM <br />CBC CALIFORNIA BUILDING CODE <br />C.G.CENTER OF GRAVITY <br />C.I.P. CAST-IN-PLACE <br />C.J. CEILING JOIST <br />CL CENTER LINE <br />CLR. CLEAR <br />COL. COLUMN <br />CONC. CONCRETE <br />CONN. CONNECTION <br />CONST.CONSTRUCTION <br />CONT. CONTINUOUS <br />DBL. DOUBLE <br />DBA.DOWEL BAR ANCHOR <br />DF DOUGLAS FIR/LARCH <br />DL DEAD LOAD <br />DP. DEEP <br />DIA. DIAMETER <br />DIM. DIMENSION <br />DO DITTO (REPEAT) <br />DWG. DRAWING <br />DWL. DOWEL <br />(E) EXISTING <br />EA. EACH <br />E.F. EACH FACE <br />EL. ELEVATION <br />ELEC. ELECTRICAL <br />ELEV. ELEVATOR <br />EMBED. EMBEDMENT <br />E.N. EDGE NAIL <br />EQ. EQUAL OR EQUIVALENT <br />E.S. EACH SIDE <br />E.W. EACH WAY <br />EXT. EXTERIOR <br />FA FRAMING/SHEAR CONNECTOR <br />FDN. FOUNDATION <br />F.F. FINISHED FLOOR <br />F.J. FLOOR JOIST <br />F.O.C. FACE OF CONCRETE <br />F.O.M. FACE OF MASONRY <br />F.O.S. FACE OF STUD <br />FRM. FRAMING <br />FRT FIRE-RETARDANT TREATED <br />F.S. FAR SIDE <br />FTG. FOOTING <br />GA GAUGE <br />GALV. GALVANIZED <br />GLB GLUED LAMINATED BEAM <br />GR GRADE <br />H. HORIZONTAL <br />HDR. HEADER <br />HGR. HANGER <br />HT. HEIGHT <br />HORIZ. HORIZONTAL <br />H.S.H. HORIZONTALLY SLOTTED HOLES <br />I.D. INSIDE DIAMETER <br />I.F. INSIDE FACE <br />I JST. I-JOIST <br />INT. INTERIOR <br />I.O.R.INSPECTOR OF RECORD <br />JST. JOIST <br />JT. JOINT <br />LDGR. LEDGER <br />L.L. LIVE LOAD <br />LT. WT. LIGHT WEIGHT <br />MATL. MATERIAL <br />MAX. MAXIMUM <br />M.B. MACHINE BOLT <br />MECH. MECHANICAL <br />MFR. MANUFACTURER <br />MIN. MINIMUM <br />MISC. MISCELLANEOUS <br />MTL. METAL <br />N.I.C. NOT IN CONTRACT <br />NO. NUMBER <br />N.S. NEAR SIDE <br />N.T.S. NOT TO SCALE <br />O.C. ON CENTER <br />O.D. OUTSIDE DIAMETER <br />O.F. OUTSIDE FACE <br />O.H. OPPOSITE HAND <br />OPNG. OPENING <br />OPP. OPPOSITE <br />ORIG. ORIGINAL <br />O.S.B. ORIENTED STRAND BOARD <br />PL PLATE <br />PLCS. PLACES <br />PLYWD. PLYWOOD <br />P.T. PRESERVATIVE TREATED <br />P.W. PLATE WASHER <br />R RADIUS <br />REF. REFERENCE <br />REINF. REINFORCEMENT <br />REQD. REQUIRED <br />RF. ROOF <br />RT. RAFTER CROSSTIE <br />R.R. ROOF RAFTERS <br />R.W. RETAINING WALL <br />SCHED. SCHEDULE <br />SECT. SECTION <br />SEOR STRUCTURAL ENGINEER OF RECORD <br />SEP. SEPARATION <br />SIM. SIMILAR <br />S.N. SHEAR NAIL <br />S.P. SEE PLAN <br />SPEC. SPECIFICATION <br />SQ. SQUARE <br />S.S.STAINLESS STEEL <br />STD. STANDARD <br />STGR. STAGGER <br />STIFF. STIFFENERS <br />STR. STRUCTURAL <br />STR. I STRUCTURAL I <br />T. TOP <br />T&B TOP & BOTTOM <br />T&G TONGUE & GROOVE <br />THK. THICKNESS/THICK <br />THR. THREADED <br />T.N. TOENAIL <br />T.O.P. TOP OF PARAPET <br />T.O.S. TOP OF SLAB <br />T.O.W. TOP OF WALL <br />TYP. TYPICAL <br />UBC UNIFORM BUILDING CODE <br />U.N.O. UNLESS NOTED OTHERWISE <br />V VERTICAL <br />VERT. VERTICAL <br />VIF VERIFY IN FIELD <br />V.S.H. VERTICAL SLOTTED HOLES <br />WD. WOOD <br />W.P. WATERPROOF OR WORK POINT <br />W.P.J. WEAKENED PLANE JOINT <br />WT. WEIGHT <br />W.W.F. WELDED WIRE FABRIC <br />W/ WITH <br />W/O WITHOUT <br />W.O. WHERE OCCURS <br />XS EXTRA STRONG (STEEL PIPE) <br />XXS DOUBLE EXTRA STRONG (STEEL PIPE) <br />CONCRETE: <br />CONCRETE CONSTRUCTION SHALL CONFORM WITH THE LATEST EDITION OF ACI 301, "SPECIFICATIONS FOR <br />STRUCTURAL CONCRETE FOR BUILDINGS" AND ACI 318, "BUILDING CODE REQUIREMENTS FOR REINFORCED <br />CONCRETE". SUBMIT MIX DESIGNS FOR EACH CLASS OF CONCRETE. ALL CONCRETE SHALL BE NORMAL WEIGHT <br />CONCRETE UNLESS NOTED OTHERWISE. ALL LIGHTWEIGHT CONCRETE TO BE SAND LIGHTWEIGHT CONCRETE. <br />CONCRETE CONTAINING SUPERPLASTICIZING ADMIXTURE SHALL HAVE A SLUMP NOT EXCEEDING 3", TO BE FIELD <br />VERIFIED, PRIOR TO ADDING ADMIXTURE, AND NOT EXCEEDING 8" AT PLACEMENT. CONCRETE NOT CONTAINING <br />SUPERPLASTICIZING ADMIXTURE SHALL HAVE A SLUMP NOT EXCEEDING 5" AT PLACEMENT. ADDITION OF WATER <br />TO A MIX WITH INSUFFICIENT SLUMP WILL NOT BE PERMITTED, EXCEPT AS ALLOWED PER ASTM C494. <br />MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED BE VIBRATED <br />ONLY AROUND UNDER-FLOOR DUCTS, ETC. CAST CLOSURE POUR AROUND COLUMNS AFTER DEAD LOAD IS <br />APPLIED. <br />MINIMUM CONCRETE MIX DESIGN REQUIREMENTS SHALL BE AS FOLLOWS: <br /> 28 DAY <br />STRENGTH MAX. SIZE AIR MAX. <br />ITEM F'c (PSI) AGGREGATE ENTR.SLUMP DENSITY <br />FOUNDATIONS - - - - -- - - - 3,000 1 1/2" 2% 3" 150 PCF <br />GRADE BEAM - - - - - -- - - - 3,000 3/4" 2% 3" 150 PCF <br />NOTE: A HIGHER GRADE OF CONCRETE MAY BE SUBSTITUTED FOR THOSE SHOWN ABOVE BUT <br />WILL BE SUBJECT TO THE CODE REQUIREMENTS OF THE HIGHER GRADE. <br />AGGREGATE AND AGGREGATE GRADATION SHALL CONFORM TO ASTM C33. <br />AIR ENTRAINMENT IS OPTIONAL AND WILL BE REVIEWED IN MIX SUBMITTAL. <br />FLY ASH SHALL BE CLASS F ONLY AND IS OPTIONAL AND WILL BE REVIEWED IN MIX SUBMITTAL. <br />WET CURING IS RECOMMENDED SUBMIT METHOD FOR CURING TO SEOR. <br />CONCRETE COVER OVER REINFORCING SHALL BE AS FOLLOWS U.N.O.: <br />POURED AGAINST EARTH - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3" <br />EXPOSED TO EARTH, BUT POURED AGAINST FORMS - - - - - - - - 2" <br />TYPICAL BARS IN COLUMNS WALLS AND BEAMS - - - - - - - - - - - - 1 1/2" <br />RAISED STRUCTURAL SLAB - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3/4" <br />BEFORE CONCRETE IS POURED, CHECK WITH ALL TRADES TO INSURE PROPER PLACEMENT OF ALL OPENINGS, <br />SLEEVES, CURBS, CONDUITS, BOLTS, INSERTS, ETC. RELATING TO WORK. <br />ALL SLEEVES NOT SPECIFICALLY SHOWN ON DRAWINGS SHALL BE LOCATED BY THE TRADES INVOLVED & SHALL <br />BE APPROVED BY STRUCTURAL ENGINEER. <br />DRYPACK CONCRETE SHALL BE ONE PART PORTLAND CEMENT & ONE PART SAND WITH SUFFICIENT WATER TO <br />ALLOW A SMALL AMOUNT OF PASTE TO COME TO THE SURFACE. <br />CONCRETE GROUT SHALL BE NON-SHRINKING WITH SUFFICIENT WATER TO ALLOW POURING. MINIMUM ULTIMATE <br />COMPRESSIVE STRENGTH F'C AT 28 DAYS SHALL BE 4000 PSI. <br />REINFORCING STEEL: <br />DEFORMED BARS: <br />ASTM A615 GRADE 60 FOR #3 AND LARGER. REINFORCING TO BE WELDED SHALL BE ASTM A706, GRADE 60, LOW <br />ALLOY. <br />WELDING: <br />UNLESS NOTED OTHERWISE, WELDING OF REINFORCING STEEL IS PROHIBITED. WHERE WELDING IS NOTED, WELD IN <br />ACCORDANCE WITH AWS D1.4 USING E90 SERIES ELECTRODES. SUBMIT MILL TEST REPORTS ON THE REINFORCING TO <br />BE WELDED AND THE PROPOSED WELDING PROCEDURE. <br />LAP SPLICES IN CONCRETE: <br />SEE TYPICAL DETAIL FOR LAP SPLICES IN CONCRETE BEAMS, WALLS, SLABS AND FOOTINGS. UNLESS NOTED <br />OTHERWISE, LAP SPLICES IN CONCRETE BEAMS, WALLS, SLABS AND FOOTINGS SHALL BE CLASS "B" TENSION LAP <br />SPLICES AND LAP SPLICES IN CONCRETE COLUMNS SHALL BE STANDARD COMPRESSION LAP SPLICES PER LATEST <br />EDITION OF ACI 318. STAGGER ALTERNATE SPLICES A MINIMUM OF ONE LAP LENGTH. LAPS IN WELDED WIRE FABRIC <br />SHALL BE MADE SO THAT THE OVERLAP MEASURED BETWEEN OUTERMOST CROSS WIRES OF EACH FABRIC SHEET IS <br />NOT LESS THAN THE SPACING OF CROSS WIRES PLUS 2 INCHES. ALL SPLICE LOCATIONS SUBJECT TO APPROVAL. <br />PROVIDE BENT CORNER BARS TO MATCH AND LAP WITH HORIZONTAL BARS AT CORNERS AND INTERSECTIONS OF <br />FOOTINGS AND WALLS. SPACING SHOWN FOR REINFORCING BARS ARE MAXIMUM ON CENTERS. ALL BARS PER CRSI <br />SPECIFICATIONS AND HANDBOOK. DOWEL ALL VERTICAL REINFORCING TO THE FOUNDATION. CONCRETE COLUMN <br />DOWEL EMBEDMENT SHALL BE A STANDARD COMPRESSION DOWEL EMBEDMENT LENGTH ACCORDING TO THE LATEST <br />EDITION OF ACI 318. SECURELY TIE ALL BARS IN POSITION PRIOR TO PLACING CONCRETE. SUPPORT SLAB <br />REINFORCEMENT WITH CONCRETE BLOCKS OR SUPPORT CHAIRS. REINFORCING SHALL NOT BE SUPPORTED BY <br />STAKES DRIVEN INTO THE GROUND. <br />STRUCTURAL STEEL: <br />WIDE-FLANGE SHAPES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ASTM A992, Fy = 50 KSI <br />ANGLES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -ASTM A36, Fy = 36 KSI <br />CHANNELS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ASTM A572, Fy = 50 KSI <br />HSS STEEL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ASTM A500 GR. B, Fy = 46 KSI <br />PIPE STEEL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -ASTM A53, Fy = 35 KSI <br />BOLTS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -ASTM A307 <br />ANCHOR BOLTS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ASTM F1554 GR. 36 <br />PLATES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -ASTM A529, Fy = 50 KSI OR <br />ASTM A572, Fy = 50 KSI (U.N.O.) <br />FABRICATION AND ERECTION: <br />LATEST AISC AND AWS CODES APPLY. FABRICATE AND ERECT IN ACCORDANCE WITH LATEST EDITION OF AISC <br />"SPECIFICATION FOR DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS". SPLICING OF <br />STRUCTURAL MEMBERS IS NOT PERMITTED UNLESS NOTED ON THE DRAWINGS. ALL BEAMS SHALL BE ERECTED WITH <br />THE NATURAL CAMBER UPWARDS. <br />ALL FABRICATORS SHALL BE LICENSED BY CITY OF SANTA ANA. <br />WELDING: <br />ALL WELDING SHALL BE BY CITY OF SANTA ANA CERTIFIED WELDERS HAVING CURRENT EXPERIENCE IN TYPE OF <br />WELD SHOWN ON DRAWINGS OR NOTES. CERTIFICATES SHALL BE THOSE ISSUED BY AN ACCEPTED TESTING AGENCY. <br />ALL WELDING SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF AWS "CODE FOR ARC AND GAS WELDING IN <br />BUILDING CONSTRUCTION". USE E70 SERIES LOW HYDROGEN ELECTRODES. SHOP WELDS AND FIELD WELDS SHALL BE <br />SHOWN ON SHOP DRAWINGS. ALL COMPLETE PENETRATION WELDS SHALL BE TESTED AND CERTIFIED BY AN <br />INDEPENDENT TESTING AGENCY. ALL DEFORMED BAR ANCHORS, HEADED STUDS AND THREADED STUDS SHALL BE <br />END WELDED PER MANUFACTURER'S RECOMMENDATIONS. <br />BOLTS: <br />ALL BOLTS, ANCHOR BOLTS, EXPANSION BOLTS, ETC., SHALL BE INSTALLED WITH STEEL WASHERS. USE TYPE X BOLTS <br />U.N.O. PER LATEST EDITION OF AISC "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" <br />AND SHALL BE TIGHTENED TO THE SNUG-TIGHT CONDITION AS DEFINED BY AISC UNLESS NOTED OTHERWISE. <br />SNUG-TIGHT IS DEFINED AS THE TIGHTNESS ATTAINED BY A FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL <br />EFFORT OF A MAN USING AN ORDINARY SPUD WRENCH. SNUG TIGHTENING SHALL PROGRESS SYSTEMATICALLY FROM <br />THE MOST RIGID PART OF THE CONNECTION TO THE FREE EDGES, AND THEN THE BOLTS OF THE CONNECTION SHALL <br />BE RETIGHTENED IN A SIMILAR SYSTEMATIC MANNER AS NECESSARY UNTIL ALL BOLTS ARE SIMULTANEOUSLY SNUG <br />TIGHT AND THE CONNECTION IS FULLY COMPACTED. <br />WELDING HOT WORK INSIDE BUILDING ENVELOPE: <br />OBTAIN A SPECIAL PERMIT FROM LA HABRA FIRE DEPARTMENT. THE SPECIAL PERMIT MUST BE <br />DISPLAYED AT THE WORK SITE DURING ALL HOT WORK. <br />ALL BUILDING OCCUPANTS MUST BE SUITABLY PROTECTED AGAINST HAZARDS GENERATED BY THE <br />WORK. (I.E. HEAT, SPARKS, FUMES, WELDING RAYS, ETC.) <br />PORTABLE WELDING FLUME EXTRACTORS (WELDING SMOKE EATERS) SHALL BE USED DURING ALL <br />WELDING OPERATIONS INSIDE THE BUILDING ENVELOPE. <br />BEFORE HOT WORK BEGINS: <br />A. AN APPROPRIATE FIRE EXTINGUISHER MUST BE AVAILABLE AND OPERABLE. <br />B. FLAMMABLE AND IGNITABLE MATERIALS AND DEBRIS MUST BE MOVED AT LEAST 35 FEET FROM <br />THE HOT WORK AREA OR COVERED AND PROTECTED FROM THE HOT WORK BY FIRE RESISTANT <br />MATERIAL. <br />C. EXPLOSIVES, OXYGEN ACETYLENE TANKS, FLAMMABLE LIQUIDS, COMPRESS GAS CYLINDERS OR <br />STORED FUEL MUST BE MOVED AT LEAST 50 FEET FROM THE HOT WORK AREA OR COVERED <br />AND PROTECTED FROM THE HOT WORK BY FIRE RESISTANT MATERIAL. <br />D. SMOKE AND FIRE DETECTORS IN THE IMMEDIATE AREA OF THE HOT WORK MUST BE <br />TEMPORARILY DISABLED UNTIL THE HOT WORK IS COMPLETED. <br />E. ADEQUATE VENTILATION MUST BE PROVIDED, ESPECIALLY WHEN CUTTING OR WELDING <br />MATERIAL WITH PAINTED OR COATED SURFACES. <br />F. IF WORK IMPACTS BUILDING OCCUPANTS, THE WORK MUST BE COORDINATED WITH THEM. <br />BUILDING OCCUPANTS MUST BE PROTECTED OR ISOLATED FROM THE HOT WORK AREA. <br />G. CRACKS OR HOLES IN FLOORS, WALLS, AND CEILING (INCLUDING DUCTWORK) MUST BE <br />PROPERLY COVERED OR PLUGGED. <br />H. HOT WORK EQUIPMENT MUST BE OPERABLE AND IN GOOD REPAIR. <br />J. A FIRE WATCH MUST BE IMPLEMENTED IF CONDITIONS WARRANT. IF NO FIRE HAZARDS OR <br />COMBUSTIBLE EXPOSURES ARE PRESENT A FIRE WATCH IS NOT REQUIRED. <br />K. WORKERS AND FIRE WATCH PERSONNEL MUST BE KNOW HOW TO USE FIRE EXTINGUISHING <br />EQUIPMENT AND HOW TO ACTIVATE THE FIRE ALARM SYSTEM. <br />WHEN HOT WORK IS COMPLETE: <br />A. THE WORK AREA AND ANY POTENTIALLY AFFECTED SURROUNDING AREAS MUST BE INSPECTED <br />FOR FIRE, FIRE DAMAGE OR THE POTENTIAL FOR FIRE FOR A MINIMUM OF 30 MINUTES <br />FOLLOWING COMPLETION OF THE HOT WORK. <br />B. SMOKE/FIRE ALARMS THAT WERE DISABLED BECAUSE OF HOT WORK MUST BE REACTIVATED. <br />WHEN INSTALLING DRILLED-IN ANCHORS IN EXISTING NON-PRESTRESSED REINFORCED <br />CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE EXISTING <br />REINFORCING BARS. WHEN INSTALLING ANCHORS INTO EXISTING PRESTRESSED CONCRETE <br />(PRE- OR POST-TENSIONED) LOCATE THE PRESTRESSED TENDONS BY USING A <br />NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION. EXERCISE EXTREME CARE AND CAUTION <br />TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATIOIN. MAINTAIN A MINIMUM <br />CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. <br />ALL DRILLED HOLES SHALL BE CLEANED IN STRICT ACCORDANCE PER ESR REPORT. UNCLEAN <br />HOLE INSTALLATIONS ARE NOT PERMITTED ON THIS PROJECT. <br />ANCHOR BOLTS SHALL NOT BE INSTALLED INTO CONCRETE PATCHES, GROUT POCKETS, OR <br />OTHERWISE INADEQUATE CONCRETE SUBSTRATE. WHERE AN ANCHOR IS SHOWN INTO SUCH <br />MATERIALS THE SEOR SHALL BE NOTIFIED AND CONSTRUCTION SHALL WAIT FOR FURTHER <br />INSTRUCTION. <br />ALL WALL ANCHORS SHALL BE PROTECTED FROM WEATHER EXPOSURE. ANY WEATHER <br />EXPOSED EXTERIOR ANCHOR RODS SHALL BE STAINLESS STEEL. <br />ADHESIVE ANCHORS INSTALLED IN HORIZONTAL OR UPWARDLY INCLINED ORIENTATIONS TO <br />RESIST SUSTAINED TENSION LOADS SHALL BE CONTINUOUSLY INSPECTED DURING <br />INSTALLATION BY AN INSPECTOR SPECIALLY APPROVED FOR THAT PURPOSE BY THE BUILDING <br />OFFICIAL (ACI 318-14 17.8.2.4) <br />PERIODIC SPECIAL INSPECTION IS REQUIRED DURING ANCHOR INSTALLATION TO VERIFY <br />ANCHOR TYPE, ANCHOR DIMENSIONS, CONCRETE TYPE, CONCRETE COMPRESSIVE STRENGTH, <br />ADHESIVE IDENTIFICATION AND EXPIRATION DATE, HOLE DIMENSIONS, HOLE CLEANING <br />PROCEDURES, ANCHOR SPACING, EDGE DISTANCE, CONCRETE THICKNESS, TIGHTENING <br />TORQUE, ANCHOR EMBEDMENT, AND ADHERENCE TO THE MANUFACTURER'S PRINTED <br />INSTALLATION INSTRUCTIONS. THE SPECIAL INSPECTOR MUST ALWAYS BE ON SITE FOR THE <br />FIRST ANCHOR INSTALLATIONS. THE SPECIAL INSPECTOR MUST VERIFY THE INITIAL <br />INSTALLATIONS OF EACH TYPE AND SIZE OF ADHESIVE ANCHOR BY CONSTRUCTION <br />PERSONNEL ON-SITE. SUBSEQUENT INSTALLATIONS OF THE SAME ANCHOR TYPE AND SIZE BY <br />THE SAME CONSTRUCTION PERSONNEL SHALL BE PERMITTED TO BE PERFORMED IN THE <br />ABSENCE OF THE SPECIAL INSPECTOR. ANY CHANGE IN THE ANCHOR PRODUCT OR <br />PERSONNEL REQUIRES AN INITIAL INSPECTION. <br />ANY PANEL JOINTS, COLD JOINTS, OR WALL ENDS THAT OCCUR WITHIN 1.5 X EMBEDMENT OF <br />THE ANCHOR SHALL BE REPORTED TO THE SEOR UNLESS THE MINIMUM EDGE DISTANCE IS <br />SPECIFICALLY DETAILED AND SHOWN IN A DETAIL. <br />TENSION TEST NOTES WHEN APPLICABLE: <br />REACTION LOADS FROM TEST FIXTURES MAY BE APPLIED CLOSE TO THE ANCHOR BEING <br />TESTED, PROVIDED THE ANCHOR IS NOT RESTRAINED FROM WITHDRAWING BY THE FIXTURE(S). <br />TEST EQUIPMENT SHALL BE CALIBRATED BY AN APPROVED TESTING LABORATORY IN <br />ACCORDANCE WITH STANDARD RECOGNIZED PROCEDURES. <br />WHEN TENSION TESTS ARE REQUIRED, REQUIRED TEST LOADS SHALL BE DETERMINED BASED <br />ON THE LESSER OF THE CALCULATED TENSION LOAD AS DETERMINED IN ACCORDANCE WITH <br />THE ICC-ESR FOR THE SPECIFIC ANCHOR OR 80% (0.8 Ase Fya) OF THE NOMINAL YIELD <br />STRENGTH OF THE ANCHOR ELEMENT, FOR A SINGLE ANCHOR WITH NO EDGE OR SPACING <br />CONFLICTS. WHERE ALL LIGHTWEIGHT CONCRETE OCCURS, MULTIPLY TEST LOAD BY 0.6. <br />WHERE SAND LIGHTWEIGHT CONCRETE OCCURS, MULTIPLY TEST LOADS BY 0.68. EXPANSION <br />ANCHORS MAY BE TORQUE-TESTED, IN LIEU OF TENSION LOAD TESTS. TEST LOADS ARE FOR <br />CRITICAL EDGE DISTANCE, IF LESS THAN CRITICAL EDGE DISTANCES, CONTACT E.O.R. FOR <br />VALUES. TENSION TEST LOADS REFLECT A VALUE THAT IS EQUAL TO 1.25 x STRENGTH DESIGN <br />CAPACITY FOR ANCHORS IN CONCRETE. <br />THE FOLLOWING CRITERIA APPLY FOR THE ACCEPTANCE OF INSTALLED ANCHORS: HYDRAULIC <br />RAM METHOD: THE ANCHOR SHOULD HAVE NO OBSERVABLE MOVEMENT AT THE APPLICABLE <br />TEST LOAD. A PRACTICAL WAY TO DETERMINE OBSERVABLE MOVEMENT IS THAT THE WASHER <br />UNDER THE NUT BECOMES LOOSE. <br />TESTING BASED ON THE ICC-ESR SHOULD OCCUR 24 HOURS MINIMUM AFTER INSTALLATION OF <br />THE SUBJECT ANCHORS. <br />TORQUE TESTING EPOXY ANCHORS IS NOT PERMITTED. <br />IF ANY ANCHOR FAILS TESTING, NOTIFY THE SEOR FOR FURTHER TESTING FREQUENCY. <br />3 8" DIA. <br />1 2" DIA. <br />5 8" DIA. <br />3 4" DIA. <br />7 8" DIA. <br />1" DIA. <br />23 8" <br />23 4" <br />31 8" <br />31 2" <br />33 4" <br />4" <br />13 4" <br />13 4" <br />13 4" <br />13 4" <br />13 4" <br />13 4" <br />** MIN CONCRETE STRENGTH = 3000 PSI <br />(HARDROCK), ALL-THREAD ROD SHALL BE ASTM <br />A-36 GALVANIZED WHERE EMBEDMENT < 8" AND <br />ASTM A-193 B7 AT ALL OTHER CONDITIONS <br />U.N.O. <br />* MIN CONCRETE THICKNESS <br />1.25" + EMBEDMENT UP TO 1 2" DIA. OR #4 <br />REBAR <br />2*do + EMBENDMENT FOR 5 8" DIA. OR #5 <br />REBAR AND LARGER <br />** MIN CONCRETE STRENGTH = 3000 PSI <br />(HARDROCK), REBAR SHALL BE ASTM A615, <br />GRADE 60. <br />23 4" <br />31 8" <br />31 2" <br />33 4" <br />13 4" <br />13 4" <br />13 4" <br />13 4" <br />11 4" DIA.5"23 4" <br />23 8"13 4" <br />4"13 4" <br />5"23 4" <br />* MIN CONCRETE THICKNESS <br />1.25" + EMBEDMENT UP TO 1 2" DIA. OR #4 <br />REBAR <br />2*do + EMBENDMENT FOR 5 8" DIA. OR #5 <br />REBAR AND LARGER <br />EPOXY ANCHOR RODS (ALL-THREAD AND REBAR): <br />EPOXY ANCHORS NOTED IN DRAWINGS ARE SIMPSON SET-3G (ICC ESR-4057) ANCHORS SYSTEM, <br />OR APPROVED EQUAL. <br />MINIMUM EMBEDMENT DEPTHS AND EDGE DISTANCES ARE AS FOLLOWS <br />UNLESS NOTED OTHERWISE. <br />ALL-THREAD <br />ROD ANCHOR <br />SIZE (DIA.) <br />EPOXY ANCHOR <br /> MINIMUM <br />EMBEDMENT* <br />MIN. EDGE <br /> DIST <br />EPOXY ANCHOR <br /> MINIMUM <br />EMBEDMENT* <br />MIN. EDGE <br /> DIST <br />REBAR <br />ANCHOR <br />SIZE (DIA.) <br />#3 <br />#4 <br />#5 <br />#6 <br />#7 <br />#8 <br />#10 <br />VOLUNTARY RETROFIT NOTICE: <br />THE PURPOSE OF THIS PROPOSED SEISMIC RETROFIT IS TO PROMOTE <br />PUBLIC WELFARE AND SAFETY BY REDUCING THE RISK OF DEATH OR <br />INJURY THAT MAY RESULT FROM THE EFFECTS OF EARTHQUAKES ON <br />EXISTING WOOD-FRAMED MULTI-STORY BUILDINGS WITH SOFT, WEAK OR <br />OPEN FRONT WALLS. IN THE 1994 NORTHRIDGE EARTHQUAKE, MANY <br />MULTI-STORY WOOD-FRAME BUILDINGS WITH TUCK-UNDER PARKING <br />PERFORMED POORLY AND COLLAPSED, CAUSING THE LOSS OF HUMAN <br />LIFE, PERSONAL INJURY AND PROPERTY DAMAGE. IT HAS BEEN <br />DETERMINED THAT THE STRUCTURAL VULNERABILITY OF THIS BUILDING <br />TYPE IS TYPICALLY DUE TO SOFT, WEAK OR OPEN-FRONT WALLS. THIS <br />PROPOSED SEISMIC RETROFIT MEETS THE MINIMUM STANDARDS TO <br />MITIGATE HAZARDS FROM THESE DEFICIENCIES. ADHERENCE TO THESE <br />MINIMUM STANDARDS WILL IMPROVE THE PERFORMANCE OF THESE <br />BUILDINGS DURING EARTHQUAKES, BUT NOT NECESSARILY PREVENT, THE <br />LOSS OF LIFE, INJURY OR EARTHQUAKE-RELATED DAMAGE. <br />THE PROPOSED SEISMIC RETROFIT MITIGATES ONLY THE ASSOCIATED <br />RISKS WITH THE TUCK-UNDER PARKING THAT CREATE A SOFT, WEAK OR <br />OPEN-FRONT WALLS. THIS PROPOSED RETROFIT DOES NOT ELIMINATE OR <br />CORRECT ALL EARTHQUAKE HAZARDS THAT MAY BE KNOWN OR <br />UNKNOWN. CONSTRUCTION FLAWS, HIDDEN STRUCTURAL <br />DETERIORATION, PEST DAMAGE AND OTHER STRUCTURAL DEFICIENCIES <br />MAY BE PRESENT BUT ARE NOT CORRECTED BY THIS PROPOSED <br />RETROFIT. <br />GENERAL: <br />THE STRUCTURAL CONTRACT DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. <br />THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE STRUCTURE IS DESIGNED TO BE A STABLE <br />UNIT AS A COMPLETED WHOLE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DESIGN, ERECT AND INSPECT <br />TEMPORARY SHORES, BRACES, ETC. TO SUPPORT THE STRUCTURE AGAINST ALL ANTICIPATED LOADS <br />INCLUDING GRAVITY, WIND AND LATERAL EARTH PRESSURE UNTIL ITS COMPLETION. OBSERVATION VISITS <br />TO THE SITE BY THE STRUCTURAL ENGINEER SHALL NOT INCLUDE INSPECTION OF THESE METHODS OF <br />CONSTRUCTION. CONSTRUCTION MATERIAL SHALL BE PLACED ON FRAMED FLOORS AND ROOFS SUCH THAT <br />THE DESIGN LIVE LOADS ARE NOT EXCEEDED. <br />THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE CONDITIONS PRIOR TO STARTING <br />CONSTRUCTION. RESOLVE ANY DISCREPANCY WITH THE ARCHITECT. <br />WORKMANSHIP AND MATERIALS SHALL COMPLY WITH SANTA ANA MUNICIPAL CODE & 2022 CBC AND ALL <br />OTHER APPLICABLE REGULATIONS. <br />NOTES AND DETAILS ON THE DRAWINGS TAKE PRECEDENCE OVER THE GENERAL STRUCTURAL NOTES AND <br />TYPICAL DETAILS. "TYPICAL" DETAILS ARE NOT FLAGGED ON THE DRAWINGS, BUT APPLY UNLESS NOTED <br />OTHERWISE. <br />COORDINATION: <br />ALL DRAWINGS ARE CONSIDERED TO BE PART OF THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE <br />RESPONSIBLE FOR COORDINATING THE DRAWINGS AND SPECIFICATIONS AMONG THE SUBCONTRACTORS <br />PRIOR TO START OF CONSTRUCTION. ANY DISCREPANCIES THAT ARE FOUND SHALL BE BROUGHT TO THE <br />ATTENTION OF THE ARCHITECT PRIOR TO START OF CONSTRUCTION. ANY WORK PERFORMED IN CONFLICT <br />WITH THE CONTRACT DOCUMENTS OR ANY CODE REQUIREMENTS SHALL BE CORRECTED BY THE CONTRACTOR <br />AT HIS OWN EXPENSE AND AT NO EXPENSE TO THE OWNER OR ARCHITECT. <br />COORDINATION SHALL INCLUDE, BUT NOT BE LIMITED TO, VERIFYING THE LOCATION AND WEIGHT OF ALL <br />MECHANICAL AND ELECTRICAL EQUIPMENT AS WELL AS THE SIZE AND LOCATION OF ALL MECHANICAL <br />OPENINGS IN ROOFS, FLOORS AND WALLS. UNLESS OTHERWISE NOTED ON THE DRAWINGS, DO NOT <br />PENETRATE ANY STRUCTURAL ELEMENTS SUCH AS BEAMS, COLUMNS, WALLS, SLABS, ETC. WITHOUT PRIOR <br />WRITTEN APPROVAL OF THE STRUCTURAL ENGINEER THROUGH THE ARCHITECT. <br />COORDINATION SHALL INCLUDE, BUT NOT BE LIMITED TO, DETERMINING THE LOCATION OF ALL EXISTING UTILITY <br />LINES THAT MAY INTERFERE WITH THE INSTALLATION OF THE NEW STRUCTURAL ELEMENTS. THE CONTRACTOR <br />SHALL INFORM THE OWNER IF INTERFERENCE IS ENCOUNTERED. THE OWNER WILL DETERMINE IF THE LINES <br />ARE TO BE REMOVED OR RELOCATED. <br />SHOP DRAWINGS: <br />SHOP DRAWING SUBMITTALS TO THE ENGINEER ARE REQUIRED FOR ALL STRUCTURAL WORK, UNLESS <br />OTHERWISE AGREED TO BY THE ARCHITECT/ENGINEER. NO WORK SHALL PROCEED WITHOUT THE REVIEW <br />AND APPROVAL OF SHOP/ERECTION/LAYOUT DRAWINGS BY THE ARCHITECT AND ENGINEER. ALL SUBMITTALS <br />SHALL BE MADE IN A TIMELY MANNER ALLOWING ADEQUATE TIME AS NEEDED BY THE ARCHITECT AND <br />ENGINEER FOR REVIEW. <br />THE CONTRACTOR SHALL REVIEW AND APPROVE ALL SHOP DRAWINGS PRIOR TO ENGINEERING REVIEW. <br />SUBMISSIONS FOR ENGINEERING REVIEW SHALL INCLUDE A REPRODUCIBLE AND ONE COPY; REPRODUCIBLE <br />WILL BE MARKED AND RETURNED. <br />CODE: <br />SANTA ANA MUNICIPAL CODE & 2022 CALIFORNIA BUILDING CODE (EARTHQUAKE FORCE REDUCED 25% FROM <br />CURRENT CODE VALUES) <br />SEISMIC: <br />IMPORTANCE FACTOR, I - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1.0 <br />RISK CATEGORY - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -II <br />Ss - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 1.305 <br />S1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 0.466 <br />SITE SOIL CLASS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D - DEFAULT <br />SDs - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1.044 <br />SD1 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -N/A <br />Fa - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -1.2 <br />Fv - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - N/A <br />SDC - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - D <br />STEEL SPECIAL CANTILEVER COLUMN - - - - - - - - - - - - - - - - - - - - R = 2.5 <br />Ωo = 1.25 <br />Cd = 2.5 <br />FOUNDATION: <br />ALLOWABLE SOIL BEARING PRESSURE = 1500 PSF (1/3 INCREASE FOR WIND OR SEISMIC) 2022 CBC MINIMUM VALUES. <br />CONTRACTOR SHALL COMPLY WITH ALL PROVISIONS OF 2022 CBC. <br />ALL EXCAVATIONS, COMPACTION & BACKFILL SHALL HAVE CONTINUOUS OR PERIODIC INSPECTION BY GEOTECH <br />ENGINEER OF RECORD. <br />GEOTECH TO INSPECT AND APPROVE FOUNDATION AND SUBMIT APPROVAL TO OWNER/REPRESENTATIVE, PRIOR TO <br />CONSTRUCTION INSPECTION. <br />IF ADVERSE SOIL CONDITIONS ARE ENCOUNTERED, A SOILS INVESTIGATION REPORT MAY BE REQUIRED. <br />NO IMPACT TOOLS SHALL BE PERMITTED WHEN REMOVING EXISTING FOOTING. SAW CUTTING FOOTING ONLY IS <br />ALLOWED. <br />INSPECTIONS: <br />THE OWNER SHALL EMPLOY AN INSPECTOR TO PROVIDE INSPECTION PER CBC CHAPTER 17 AND LOCAL <br />CODES. ALL SPECIAL INSPECTORS SHALL BE APPROVED BY CITY OF SANTA ANA DEPARTMENT OF BUILDING & <br />SAFETY. <br />CONTRACTORS RESPONSIBLE FOR THE CONSTRUCTION OF A SEISMIC FORCE RESISTING <br />SYSTERM/COMPONENT LISTED IN THE "STATEMENT OF SPECIAL INSPECTION" SHALL SUBMIT A WRITTEN <br />STATEMENT OF RESPONSIBILITY TO THE SANTA ANA DEPARTMENT OF BUILDING AND SAFETY INSPECTORS <br />AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON SUCH SYSTEM OR COMPONENT. <br />PRE-CONSTRUCTION MEETING: <br />UPON EXCAVATION AND EXPOSURE OF EXISTING STRUCTURAL ELEMENTS AND CONNECTIONS AND PRIOR <br />INSTALLATION OF ANY NEW STRUCTURAL ELEMENTS OR MEMBERS, THE OWNER OR OWNER'S <br />REPRESENTATIVE SHALL ARRANGE A PRE-CONSTRUCTION MEETING TO BE ATTENDED BY THE ENGINEER OR <br />ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGN, CONTRACTOR AND THE BUILDING INSPECTOR. THE <br />PURPOSE OF THE MEETING SHALL BE TO IDENTIFY THE MAJOR STRUCTURAL ELEMENTS, CONNECTIONS AND <br />EXISTING CONDITIONS THAT EFFECT THE VERTICAL AND LATERAL LOAD SYSTEMS OF THE STRUCTURE AND TO <br />REVIEW SCHEDULING OF THE REQUIRED OBSERVATIONS. <br />INSPECTIONS REQUIRED: <br />THE OWNER OR THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE ACTING AS THE <br />OWNER'S AGENT SHALL EMPLOY ONE OR MORE DEPUTY INSPECTORS TO PERFORM INSPECTIONS <br />DURING CONSTRUCTION ON THE TYPES OF WORK THAT REQUIRE SPECIAL INSPECTIONS. <br />CONTINUOUS INSPECTIONS: <br />A.FIELD WELDING <br />B.CONCRETE PLACEMENT FOR CONC STRENGTH f'c>2500 PSI <br />CITY OF SANTA ANA DEPARTMENT OF BUILDING AND SAFETY: GENERAL NOTES FOR STRUCTURAL <br />OBSERVATION: <br />STRUCTURAL OBSERVATION IS REQUIRED FOR THE STRUCTURAL SYSTEM IN ACCORDANCE WITH 2022 <br />CBC CHAPTER 17. STRUCTURAL OBSERVATION IS THE VISUAL OBSERVATION OF THE ELEMENTS AND <br />CONNECTIONS OF THE STRUCTURAL SYSTEMS AT SIGNIFICANT CONSTRUCTION STAGES AND THE <br />COMPLETED STRUCTURE FOR GENERAL CONFORMANCE TO THE APPROVED PLANS AND <br />SPECIFICATIONS. STRUCTURAL OBSERVATION DOES NOT WAIVE THE RESPONSIBILITY FOR THE <br />INSPECTIONS REQUIRED OF THE BUILDING INSPECTOR OR THE DEPUTY INSPECTOR. <br />THE OWNER SHALL EMPLOY A CIVIL OR STRUCTURAL ENGINEER OR ARCHITECT TO PERFORM THE <br />STRUCTURAL OBSERVATION. THE ENGINEER OR ARCHITECT SHALL BE REGISTERED OR LICENSED IN <br />THE STATE OF CALIFORNIA. THE DEPARTMENT OF BUILDING AND SAFETY RECOMMENDS THE USE OF <br />THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGN WHEN THEY ARE <br />INDEPENDENT OF THE CONTRACTOR. <br />THE STRUCTURAL OBSERVER SHALL PROVIDE EVIDENCE OF EMPLOYMENT BY THE OWNER. A LETTER <br />FROM THE OWNER OR A COPY OF THE AGREEMENT FOR SERVICES SHALL BE SENT TO THE BUILDING <br />INSPECTOR BEFORE THE FIRST SITE VISIT. THE STRUCTURAL OBSERVER SHALL ALSO INFORM THE <br />OWNER OF THE REQUIREMENTS FOR A PRECONSTRUCTION MEETING AND SHALL PRESIDE OVER THIS <br />MEETING. <br />THE OWNER OR OWNER'S REPRESENTATIVE SHALL COORDINATE AND CALL FOR A MEETING BETWEEN <br />THE ENGINEER OR ARCHITECT RESPONSIBLE FOR THE STRUCTURAL DESIGN, STRUCTURAL <br />OBSERVER, CONTRACTOR, AFFECTED SUBCONTRACTORS AND DEPUTY INSPECTORS. THE PURPOSE <br />OF THE MEETING SHALL BE IDENTIFY THE MAJOR STRUCTURAL ELEMENTS AND CONNECTIONS THAT <br />AFFECT THE VERTICAL AND LATERAL LOAD SYSTEMS OF THE STRUCTURE AND TO REVIEW <br />SCHEDULING OF THE REQUIRED OBSERVATIONS. A RECORD OF THE MEETING SHALL BE INCLUDED IN <br />THE FIRST OBSERVATION REPORT SUBMITTED TO THE BUILDING INSPECTOR. <br />THE STRUCTURAL OBSERVER SHALL PERFORM SITE VISITS AT THOSE STEPS IN THE PROGRESS OF <br />THE WORK THAT ALLOW FOR CORRECTION OF DEFICIENCIES WITHOUT SUBSTANTIAL EFFORT OR <br />UNCOVERING OF THE WORK INVOLVED. AT A MINIMUM, THE FOLLOWING SIGNIFICANT CONSTRUCTION <br />STAGES REQUIRE A SITE VISIT AND AN OBSERVATION REPORT FROM THE STRUCTURAL OBSERVER. <br />SCHEDULED INTERVAL OR STAGE OF CONSTRUCTION <br />a. FOUNDATION PRIOR TO CONCRETE PLACEMENT. <br />b. COMPLETION OF STEEL & FRAMING PRIOR TO COVERING. <br />THE STRUCTURAL OBSERVER SHALL PREPARE A REPORT FOR EACH SIGNIFICANT STAGE OF <br />CONSTRUCTION OBSERVED. THE ORIGINAL OF THE OBSERVATION REPORT SHALL BE SENT TO THE <br />BUILDING INSPECTOR'S OFFICE AND SHALL BE SIGNED AND SEALED (WET STAMP) BY THE <br />RESPONSIBLE STRUCTURAL OBSERVER. ONE COPY OF THE OBSERVATION REPORT SHALL BE <br />ATTACHED TO THE APPROVED PLANS. THE COPY ATTACHED TO THE PLANS NEED NOT BE SEALED BUT <br />SHALL BE SIGNED BY THE RESPONSIBLE STRUCTURAL OBSERVER OR THEIR DESIGNEE. COPIES OF <br />THE REPORT SHALL ALSO BE GIVEN TO THE OWNER, CONTRACTOR, AND DEPUTY INSPECTOR. <br />A FINAL OBSERVATION REPORT MUST BE SUBMITTED WHICH SHOWS THAT ALL OBSERVED <br />DEFICIENCIES WERE RESOLVED AND THE STRUCTURAL SYSTEM GENERALLY CONFORMS WITH THE <br />APPROVED PLANS AND SPECIFICATIONS. THE DEPARTMENT OF BUILDING AND SAFETY WILL NOT <br />ACCEPT THE STRUCTURAL WORK WITHOUT THIS FINAL OBSERVATION REPORT AND THE CORRECTION <br />OF SPECIFIC DEFICIENCIES NOTED DURING NORMAL BUILDING AND DEPUTY INSPECTION. <br />THE STRUCTURAL OBSERVER SHALL SEND THE ORIGINAL OBSERVATION REPORT TO THE INSPECTION <br />OFFICE. <br />WHEN THE OWNER ELECTS TO CHANGE THE STRUCTURAL OBSERVER OF RECORD, THE OWNER SHALL: <br />A. NOTIFY THE BUILDING INSPECTOR IN WRITING BEFORE THE NEXT INSPECTION. <br />B. CALL AN ADDITIONAL PRECONSTRUCTION MEETING, AND. <br />C. FURNISH THE REPLACEMENT STRUCTURAL OBSERVER WITH A COPY OF ALL PREVIOUS <br />OBSERVATION REPORT. <br />THE REPLACEMENT STRUCTURAL OBSERVER SHALL APPROVE THE CORRECTION OF THE ORIGINAL <br />OBSERVED DEFICIENCIES UNLESS OTHERWISE APPROVED BY PLAN CHECK SUPERVISION. THE POLICY <br />OF THE DEPARTMENT SHALL BE TO CORRECT ANY PROPERLY NOTED DEFICIENCIES WITHOUT <br />CONSIDERATION OF THEIR SOURCE <br />THE ENGINEER OR ARCHITECT OF RECORD SHALL DEVELOP ALL CHANGES RELATING TO THE <br />STRUCTURAL SYSTEMS. THE BUILDING DEPARTMENT SHALL REVIEW AND APPROVE ALL CHANGES TO <br />THE APPROVED PLANS AND SPECIFICATIONS . <br />DEAD LOADS: <br />ROOF - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -11.0 PSF <br />2ND FLOOR - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -35.0 PSF (FLOOR AREA) <br />40.0 PSF (PLASTER CEILING) <br />ADDED NOTES PER CITY OF SANTA ANA REQUIREMENTS: <br />1. CONTRACTOR IS RESPONSIBLE FOR TEMPORARY SHORING DESIGN BY REGISTERED DESIGN <br />ENGINEER. <br />2. TEMPORARY SHORING NOT TO BE REMOVED UNTIL NEW FOUNDATION IS CAPABLE OF TAKING <br />GRAVITY LOADS. <br />3. PROVIDE LEAD HOLE 40% - 70% OF THREADED SHANK DIAMETER AND FULL DIAMETER FOR <br />SMOOTH SHANK PORTION. <br />4. A COPY OF THE ICC REPORTS AND/OR CONDITIONS OF LISTING SHALL BE MADE AVAILABLE AT THE <br />JOB SITE. <br />5. GAS PIPES NOT ALLOWED IN GRADE BEAM UNLESS APPROVAL IS OBTAINED FROM GAS COMPANY. <br />6. PROVIDE MILL CERTIFICATES FOR ALL STRUCTURAL STEEL & REINFORCING STEEL. <br />WOOD: <br />10d COMMON NAILS 3" LONG ARE TO BE USED WHERE 10d x11 2" NAILS ARE NOT SPECIFICALLY CALLED <br />OUT ON DRAWINGS OR ALLOWED BY SIMPSON CATALOG AS EQUAL SUBSTITUTION WITH EQUAL <br />CAPACITY. <br />USE OF MACHINE NAILING IS SUBJECT TO A SATISFACTORY JOBSITE DEMONSTRATION FOR EACH <br />PROJECT AND THE APPROVAL OF THE PROJECT STRUCTURAL ENGINEER AND THE ENFORCEMENT <br />AGENCY. THE APPROVAL IS SUBJECT TO CONTINUED SATISFACTORY PERFORMANCE. MACHINE <br />NAILING IS NOT ALLOWED FOR 5/16" INCH PLYWOOD. IF THE NAIL HEADS PENETRATE THE OUTER PLY <br />MORE THAN WOULD BE NORMAL FOR A HAND HELD HAMMER, OR IF MINIMUM ALLOWABLE EDGE <br />DISTANCES ARE NOT MAINTAINED, THE PERFORMANCE WILL BE DEEMED UNSATISFACTORY AND <br />MACHINE NAILING SHALL BE DISCONTINUED. <br />UNLESS SPECIFICALLY SHOWN ON THESE PLANS NO STRUCTURAL MEMBER SHALL BE CUT. NEITHER <br />DRILLED NOR NOTCHED WITHOUT PRIOR WRITTEN AUTHORIZATION FROM THE STRUCTURAL <br />ENGINEER. <br />WOOD MATERIALS: <br />PROVIDE MEMBERS AS MANUFACTURED BY TRUS JOIST CORPORATION OR AN APPROVED SUBSTITUTE WITH A <br />CURRENT ICBO APPROVAL. DESIGN, FABRICATE AND ERECT IN ACCORDANCE WITH THE APPLICABLE ICBO/ICC <br />REPORT. <br />MEMBER SIZES ARE SHOWN ON THE DRAWINGS. <br />FRAMING LUMBER: <br />BASE VALUES FOR DIMENSION LUMBER <br /> SPECIES <br />MEMBER Fb (PSI) Fv (PSI) E (PSI) F'c//(PSI) & GRADE <br />- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - <br />JOISTS 900 180 1,600,000 1300 DOUG FIR #2 <br />BEAMS <br /> 4X MEMBERS 1000 180 1,700,000 1450 DOUG FIR #1 <br /> 6X MEMBERS 1350 170 1,600,000 925 DOUG FIR #1 <br />POSTS <br /> 4X MEMBERS 1000 180 1,700,000 1450 DOUG FIR #1 <br /> 6X MEMBERS 1200 170 1,600,000 1000 DOUG FIR #1 <br />STUDS 900 180 1,600,000 1350 DOUG FIR #2 <br />LEDGERS AND <br /> TOP PLATES 875 180 1,600,000 1300 DOUG FIR #2 <br />TREATED SILL DOUG FIR #2 MIN. EACH PIECE SHALL BEAR A STAMP OF APPROVED <br /> PLATES INDEPENDENT AGENCY OPERATING UNDER AITC. <br />FRAMING LUMBER SHALL COMPLY WITH THE LATEST EDITION OF THE GRADING RULES OF THE WESTERN WOOD <br />PRODUCTS ASSOCIATION OR THE WEST COAST LUMBER INSPECTIONS BUREAU. ALL SAWN LUMBER SHALL BE <br />STAMPED WITH THE GRADE MARK OF AN APPROVED GRADING AGENCY. MOISTURE CONTENT SHALL NOT <br />EXCEED 19%. <br />ALL BOLT HOLES SHALL BE DRILLED 1 32" TO 116" OVERSIZED. <br />LEGAL DESCRIPTION: <br />APN: 109-040-40 <br />DWG <br />NUMBER SHEET TITLE <br />S0.1 GENERAL NOTES <br />S1.1 TYPICAL DETAILS <br />S2.0 SITE PLAN <br />S2.1 BUILDING F - FOUNDATION & FLOOR FRAMING PLAN <br />S2.2 BUILDING G - FOUNDATION & FLOOR FRAMING PLAN <br />S2.3 BUILDING H - PARTIAL FOUNDATION & FLOOR FRAMING PLAN <br />S2.4 BUILDING H - PARTIAL FOUNDATION & FLOOR FRAMING PLAN <br />S2.5 BUILDING I - FOUNDATION & FLOOR FRAMING PLAN <br />S3.1 BUILDING ELEVATIONS <br />S3.2 BUILDING ELEVATIONS <br />S3.3 BUILDING ELEVATIONS <br />S3.4 BUILDING ELEVATIONS <br />S5.1 DETAILS <br />S5.2 DETAILS <br />1 <br />SCOPE OF WORK: <br />1. MITIGATE SOFT STORY, WEAK STORY AND OPEN-WALL <br />LINE CONDITIONS AT TUCK UNDER PARKING AREAS. <br />CONSTRUCTION METHOD: <br />(8) SPECIAL STEEL CANTILEVERED COLUMNS WITH <br />CONCRETE GRADE BEAM AT NORTH SIDE OF BUILDING H. <br />(4) SPECIAL STEEL CANTILEVERED COLUMNS WITH <br />CONCRETE GRADE BEAM AT EAST SIDE OF BUILDING G. <br />(4) SPECIAL STEEL CANTILEVERED COLUMNS WITH <br />CONCRETE GRADE BEAM AT WEST SIDE OF BUILDING I. <br />& (4) SPECIAL STEEL CANTILEVERED COLUMNS WITH <br />CONCRETE GRADE BEAM AT SOUTH SIDE OF BUILDING F. <br />SITE <br />22 <br />N <br />E <br />U <br />C <br />L <br />I <br />D <br /> <br />S <br />T <br />HA <br />R <br />B <br />O <br />R <br /> <br />B <br />L <br />V <br />D <br />N F <br />A <br />I <br />R <br />V <br />I <br />E <br />W <br /> <br />S <br />T <br />N <br />B <br />R <br />I <br />S <br />T <br />O <br />L <br /> <br />S <br />T <br />WESTMINSTER AVE <br />W 1ST ST <br />WEST GROVE VALLEY <br />W McFADDEN AVE <br />EDINGER AVE <br />BUILDING INFO: <br />a.OCCUPANCY GROUP: RESIDENTIAL R-2 <br />b.CONSTRUCTION TYPE: V <br />c.NUMBER OF STORIES: 2 <br />d.FIRE SPRINKLER: NONE EXISTS <br />241285 7-22-24 <br />LMC / PVB <br />PVB <br />LMC / PVB <br />LMC / MBH / AYB <br />AS SHOWN <br />7-26-24 PLAN CHECK SUBMITTAL PVB <br />8-7-24 PLAN CHECK RESUBMITTAL PVB <br />10/14/24 <br />www.coffman.com <br />ph 818.285.2650 <br />6320 Canoga Ave, Suite 1300 <br />Woodland Hills, CA 91367 <br />10-14-24 PLAN CHECK RESUBMITTAL PVB <br />2701 W McFadden Ave <br />#F-I2/6/2025