Laserfiche WebLink
Page 5 of 8 <br />1760 Chicago Ave Ste J13, Riverside, CA 92507 (951) 405-1733 info@currentrenewableseng.com <br />Roof Framing Checks: <br />Force Checks <br />LC1: D+S Check 1 <br />Applied Moment (lb-ft):173.6 <br />Applied Shear (lbs):68.9 <br />Allowable Moment (lb-ft):975.1 <br />Allowable Shear (lbs):1,138.5 <br />Moment DCR:0.178 <br />Shear DCR:0.060 <br />LC2: D+0.6W Check 1 <br />Applied Moment (lb-ft):333.6 <br />Applied Shear (lbs):132.3 <br />Allowable Moment (lb-ft):1,356.7 <br />Allowable Shear (lbs):1,584.0 <br />Moment DCR:0.246 <br />Shear DCR:0.084 <br />LC3: D+0.75(S+0.6W)Check 1 <br />Applied Moment (lb-ft):293.6 <br />Applied Shear (lbs):116.5 <br />Allowable Moment (lb-ft):1,356.7 <br />Allowable Shear (lbs):1,584.0 <br />Moment DCR:0.216 <br />Shear DCR:0.074 <br />LC4: 0.6D+0.6W Check 1 <br />Applied Moment (lb-ft):264.2 <br />Applied Shear (lbs):104.8 <br />Allowable Moment (lb-ft):1,356.7 <br />Allowable Shear (lbs):1,584.0 <br />Moment DCR:0.195 <br />Shear DCR:0.066 <br />2304 W Cubbon St <br />10/4/2024