My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1995 S Standard Ave - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Standard Ave
>
1995 S Standard Ave
>
1995 S Standard Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:20:22 PM
Creation date
6/6/2025 1:20:10 PM
Metadata
Fields
Template:
Plan
Permit Number
101120656
Full Address
1995 S Standard Ave
Text box
ID:
1
Creator:
Import Agent
Created:
6/6/2025 1:20 PM
Modified:
5/30/2025 2:13 PM
Text:
www.hilti.com
ID:
2
Creator:
Import Agent
Created:
6/6/2025 1:20 PM
Modified:
5/30/2025 2:13 PM
ID:
3
Creator:
Import Agent
Created:
6/6/2025 1:20 PM
Modified:
5/30/2025 2:13 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
63
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
www.hilti.com <br />Hilti PROFIS Engineering 3.1.1 <br />Input data and results must be checked for conformity with the existing conditions and for plausibility! <br />PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan <br />1 <br />Company: <br />Address: <br />Phone I Fax: <br />Design: <br />Fastening point: <br /> | <br />Depal - Anchorage Design <br />Page: <br />Specifier: <br />E-Mail: <br />Date: <br />1 <br />7/19/2024 <br />Specifier's comments: <br />1 Input data <br /> Anchor type and diameter: HIT-HY 200 V3 + HAS-V-36 (ASTM F1554 Gr.36) 3/4 <br /> Item number: 2198030 HAS-V-36 3/4"x10" (element) / 2334276 HIT-HY <br /> 200-R V3 (adhesive) <br /> Specification text: Hilti HAS threaded rod with HIT-HY 200 V3 <br /> injection mortar with 7 in embedment hef, 3/4, <br /> Carbon steel, Safe Set System, Hammer <br /> drilled installation per ESR-4868 <br /> Effective embedment depth: hef,act = 7.000 in. (hef,limit = - in.) <br /> Material: ASTM F1554 Grade 36 <br /> Evaluation Service Report: ESR-4868 <br /> Issued I Valid: 11/1/2022 | 11/1/2024 <br /> Proof: Design Method ACI 318-19 / Chem <br /> Stand-off installation: eb = 0.000 in. (no stand-off); t = 1.250 in. <br /> Anchor plateR : lx x ly x t = 10.000 in. x 10.000 in. x 1.250 in.; (Recommended plate thickness: not calculated) <br /> Profile: no profile <br /> Base material: cracked concrete, 4000, fc' = 4,000 psi; h = 12.000 in., Temp. short/long: 32/32 °F <br /> Installation: hammer drilled hole, Installation condition: Dry <br /> Reinforcement: tension: not present, shear: not present; no supplemental splitting reinforcement present <br /> edge reinforcement: none or < No. 4 bar <br />R - The anchor calculation is based on a rigid anchor plate assumption. <br />Geometry [in.] & Loading [lb, ft.lb] <br />1995 S Standard Ave- <br />Concrete Pads10/15/2024
The URL can be used to link to this page
Your browser does not support the video tag.