Laserfiche WebLink
ASCE 30.3.2 Design Wind Pressure Beam/ Top Chord Check <br />Roof Slope =18 ° <br />Roof Shape Hip <br />Tributary Width s =2.00 ft <br />Tributary Length L =17.00 ft <br />Effective Area A = L ( MAX [ s , L/3] )=96 f 2 <br />Height of Structure h =15 ft <br />Wind Speed V =110 mph <br />Exposure Categor C <br />Building Width B =30 ft <br />Building Length L =50 ft <br />Zone Width a =3 ft <br />Elevation Height zg =51 ft <br />Wind Directionality Kd =0.85 <br />Topography Factor Kt =1.00 <br />Ground Elevation Factor Ke =1.00 <br />Velocity Pressure Exposure Coefficient Kz =0.85 <br />Velocity Pressure qz = 0.00256KzKztKdKeV2 =22.31 psf <br />Internal Pressure Coefficient (GCpi)=-0.18 <br />Zone GCp p = qz [(GCp) - (Gcpi)] <br />3 2.05 -49.86 <br />3r - - <br />3e - - <br />2 - - <br />2r 1.34 -34.02 <br />2e 2.05 -49.86 <br />2n - - <br />1 1.04 -27.14 <br />1' - - <br />1730 W Carlton Pl <br />9/23/2024