My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1730 W Carlton Pl - Plan
PBA
>
Building
>
ProjectDox
>
C
>
Carlton Pl
>
1730 W Carlton Pl
>
1730 W Carlton Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/6/2025 1:20:27 PM
Creation date
6/6/2025 1:20:15 PM
Metadata
Fields
Template:
Plan
Permit Number
20183887
20184140
101120685
101121042
Full Address
1730 W Carlton Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PV SYSTEM <br />AS INDICATED <br />September 3, 2024 <br />ENRIQUE MORAN NOVOA <br />1730 W CARLTON PL <br />SANTA ANA, CA 92704 <br />Clean Energy Solutions Inc. <br />Address: <br />1055 West 7th Street <br />33rd Floor, Los Angeles, <br />CA 90017 <br />Phone Number: <br />(800) 994 1134 <br />Lic# 998787 <br />Class C-10 <br />CONTRACTOR <br />Designed By: Intersolar CAD <br />www.intersolarcad.com <br />PV SYSTEM DC SIZE 5.53KW <br />PV SYSTEM AC SIZE 5.12KW <br />FROM PV MODULES TO JBOX <br />FROM JBOX TO INVERTER <br />(2)1 <br />(1) #6 AWG BARE CU EGC, <br />2 <br /> #10 AWG CU EGC, <br />(3) <br />3 <br />(1) #10 AWG CU EGC, <br /> MAXIMUM INVERTER OUTPUT CURRENT (A) <br /> TEMPERATURE FACTOR <br /> TEMPERATURE ADJUSTMENT (A) <br />OUTPUT CALCULATIONS <br />PV SYSTEM MAX DC OUTPUT <br />PV SYSTEM MAX AC OUTPUT <br /> MAXIMUM POWER (W) <br /> PEAK PWR TRACKING VOLTAGE (V) <br /> CONSIDER CONTINUOUS COEFFICIENT <br /> SHORT CIRCUIT CURRENT (A) <br /> ADJUSTED CONDUCTOR AMPACITY (A) <br />1.25 <br />1.25 <br />1.25 <br />0.91 <br />(2) <br />(1) <br /> Pmax (PTC Rating) <br />16.0 <br />380 <br />1 99.0 % <br />16.0 * 1.25 / 0.91 22.0 <br /> #10 AWG THWN-2 <br />SOLAR EDGE ENERGY HUB SE3800H-US (240V) <br />16.0 * 1.25 20.0 <br />1 1/2'' <br /> (TEMP - 39 + 22 = 61C)0.58 <br /> RACEWAY HEIGHT FROM ROOF <br />ADJST. FACTOR (1 thru 3 WIRES)1.0 <br />FREE IN THE AIR, 3/4'' EMT TYPE CONDUIT BETWEEN ARRAYS <br />3/4'' EMT TYPE CONDUIT <br />1'' EMT TYPE CONDUIT <br />MAIN SERVICE PANEL RATING <br />BUSBAR RATING <br />MAIN BREAKER <br />PV BACKFEED BREAKER SIZE <br />120% RULE: <br />MAX ALLOWED FEED <br />20A <br />*/*1.25 *1.2514 395 380 22.7 <br />/ /22.7 0.58 1.0 39.1 <br />#10 AWG THWN-2 <br />WIRE CHART WIRE CHART <br /> *14 395 5.53 KW <br />* *14 369.1 0.99 5.12 KW <br /> CONSIDER CONTINUOUS COEFFICIENT <br /> CONSIDER CONTINUOUS COEFFICIENT <br />200A <br />200A <br />240A <br />200A ''MB'' + 20A "SOLAR" = 220A ≤ 240A MAX <br />FROM INVERTER TO MAIN SERVICE PANEL <br /> CONSIDER CONTINUOUS (A) <br /> MAX NUMBER OF MODULES IN STRING 14 <br />#10 AWG PV-WIRE <br />14 <br />CS6R-395MS 395 W <br /> 369.1 W <br />395 <br />WIRE SIZE <br />CALCULATIONS <br />E 1.1 <br />1730 W Carlton Pl <br />9/23/2024
The URL can be used to link to this page
Your browser does not support the video tag.