Laserfiche WebLink
SNUG SPACER REQUIRED BETWEEN THE WATER <br />INSULATION BLANKET, LEAVE <br />WRAPPED AROUND TANK AND SNUG SPACER PROVIDED BETWEEN THE WATER HEATER ANDWALL, WITHIN UPPER 1/3 & LOWER 1/3 OF ITS VERTICAL DIMENSION. SCREW WITH WASHER (FOR CONCRETE WALLS,SUBSTITUTE 1/4" EXPANSION BOLTS <br />HEATER THAT IS ADJACENT TO A WALL. TANK FEET NEED TO BE BOLTED TO THE FLOOR AND THE HEATER HOOKED <br />STEEL 2X4 TO CREATE SNUG FIT BETWEEN <br />OF BRACING FOR <br />Tankless water heaters are becoming a popular, energy-efficient <br />replacement for standard tank-type heater. When installing a <br />tankless water heater there are many things to consider. <br />CAUTION: Manufacturer’s installation instructions often <br />require special venting materials and specific <br />installation practices. <br />NOTE: Most installations require larger combustion air <br />openings/ducts to be installed. <br />BEWARE: Typical tankless water heater gas demands <br />require gas pipe sizes to be significantly <br />increased or additional dedicated piping, from <br />the gas meter to the water heater, to be installed. <br />The following items will need to be provided to the inspector at <br />the time of the initial water heater inspection: <br />1.Water heater and venting material manufacturers’ <br />installation instructions. <br />2.Calculations/drawings for the increased gas <br />demand. <br />TANKLESS WATER HEATERS <br />901 E Myrtle St Unit# 2 - <br />1011181606/27/2024