901 E Myrtle St Unit# 2 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Myrtle St
>
901 E Myrtle St Unit# 2
>
901 E Myrtle St Unit# 2 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 11:08:28 AM
Creation date
6/6/2025 1:22:10 PM
Metadata
Fields
Template:
Plan
Permit Number
101118160
Full Address
901 E Myrtle St Unit# 2
Street Number
901
Street Direction
E
Street Name
Myrtle
Street Suffix
St
Unit Number
2
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
168
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />SECTION D3 – DIRECTION X <br />Building Dimension (ft):B = 41 L = 48.25 Mean Height = 15 Base Height = 0.5 <br />Section Dimension (ft):Width = 14.75 Depth = 29.5 Wind Height = 11.5 Base Height = 0.5 <br />Plate Height:ROOF = 10' <br />WIND LOAD: <br />L/B =48.25/41=1.18, Windward Wall Cpw = 0.8, Leeward Wall Cpl = -0.46, qh = 16.79 PSF Wall(LW) P = GCplqh = 6.63 PLF <br />WIND HEIGHT (FT):15 20 25 30 40 50 <br />qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 <br />Wall(WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 <br />Wall P = GCpwqz+GCplqh 17.98 18.65 19.18 19.72 20.52 21.19 <br />ROOF ELEMENT WDir+WDir-OWDir+OWDir- <br />Gable W=15', L=29.5' WW <br />Gable W=15', L=29.5' LW <br />12.81 <br />14.73 <br />22.03 <br />5.51 <br />14.73 <br />12.81 <br />5.51 <br />22.03 <br />D3X_ROOF = 68.67 = 0.6 x 114.45 PLF <br />MAX TOTAL = 68.67 PLF <br />SEISMIC LOAD:V = 0.1106W <br />W_ROOF: <br />Load_Roof (DL)= 20 x 498.5 / 14.75 = 675.93 <br />Wall_Ex (DL)= 17 x 14.75 x (10/2) / 14.75 = 85.00 <br />Wall_In (DL)= 10 x 22 x (10/2) / 14.75 = 74.58 <br />Cs*W = 0.1106 x (675.93 + 85.00 + 74.58)= 92.41 <br />TOTAL SEISMIC LOAD 92.41 = 92.41 PLF <br />Story Wx (PLF)Hx (ft) <br />Wxxhx <br />/sum(Wixhi) <br />Fx <br />(PLF) <br />Sum(Fi)Sum(Wi)Fpx(PLF) <br />Fpx <br />Min <br />Fpx <br />Max <br />Fpx <br />Design <br />D3X_ROOF 835.51 10 1 92.41 92.41 835.51 92.41 122.61 245.21 122.61 <br />DIAPHRAGM DESIGN: <br />Story Width <br />(ft) <br />Depth <br />(ft) <br />Seismic Wind Diaphragm ChordShear (plf)Chord (lb)Shear (plf)Chord (lb) <br />D3X_ROOF 14.75 29.5 30.7 113 17.2 63.3 15/32 Sheathing and Single-Floor Unblocked w/8d <br />COMMON NAILS at 6”, 6”, 12” O.C. (Shear Capacity: E=180/W=252) <br />(10 ) 16d sinker per <br />top plate splice <br /> <br />SECTION D3 – DIRECTION Y <br />Building Dimension (ft):B = 48.25 L = 41 Mean Height = 15 Base Height = 0.5 <br />Section Dimension (ft):Width = 29.5 Depth = 14.75 Wind Height = 15 Base Height = 0.5 <br />Plate Height:ROOF = 10' <br />WIND LOAD: <br />L/B =41/48.25=0.85, Windward Wall Cpw = 0.8, Leeward Wall Cpl = -0.5, qh = 16.79 PSF Wall(LW) P = GCplqh = 7.14 PLF <br />WIND HEIGHT (FT):15 20 25 30 40 50 <br />qz=0.00256KzKztKdV2 16.69 17.67 18.46 19.25 20.42 21.41 <br />Wall(WW) P = GCpwqz 11.35 12.02 12.55 13.09 13.89 14.56 <br />Wall P = GCpwqz+GCplqh 18.49 19.15 19.69 20.22 21.02 21.69 <br />ROOF ELEMENT WDir+WDir-OWDir+OWDir- <br />Hip W=29.5', L=15', Slope = 18.43° WW <br />Hip W=29.5', L=15', Slope = 18.43° LW <br />-2.27 <br />55.69 <br />27.96 <br />25.47 <br />55.69 <br />-2.27 <br />25.47 <br />27.96 <br />D3Y_ROOF = 85.72 = 0.6 x 142.86 PLF <br />MAX TOTAL = 85.72 PLF <br />SEISMIC LOAD:V = 0.1106W <br />W_ROOF: <br />Load_Roof (DL)= 20 x 498.5 / 29.5 = 337.97 <br />Wall_Ex (DL)= 17 x 59 x (10/2) / 29.5 = 170.00 <br />Wall_In (DL)= 10 x 14 x (10/2) / 29.5 = 23.73 <br />Cs*W = 0.1106 x (337.97 + 170.00 + 23.73)= 58.81 <br />TOTAL SEISMIC LOAD = 58.81 = 58.81 PLF <br />Story Wx (PLF)Hx (ft) <br />Wxxhx <br />/sum(Wixhi) <br />Fx <br />(PLF) <br />Sum(Fi)Sum(Wi)Fpx(PLF) <br />Fpx <br />Min <br />Fpx <br />Max <br />Fpx <br />Design <br />D3Y_ROOF 531.69 10 1 58.81 58.81 531.69 58.81 78.02 156.04 78.02 <br />DIAPHRAGM DESIGN: <br />Story Width <br />(ft) <br />Depth <br />(ft) <br />Seismic Wind Diaphragm ChordShear (plf)Chord (lb)Shear (plf)Chord (lb) <br />D3Y_ROOF 29.5 14.75 78 575.4 85.7 632.2 15/32 Sheathing and Single-Floor Unblocked w/8d <br />COMMON NAILS at 6”, 6”, 12” O.C. (Shear Capacity: E=180/W=252) <br />(10 ) 16d sinker per <br />top plate splice <br />vG23.06.30 <br />: <br />: <br />: <br />: <br />Company <br />Project (N) DETACHED ADU, UNIT 2 <br />Job No.231014 <br />Plan <br />: <br />: <br />: <br />: <br />Designed T.M. <br />Checked P.P. <br />Date 08/26/2024 <br />Client N/A <br />TIC Structure Design 2023 <br />Page 9 <br />901 E Myrtle St <br />Unit# 23/14/2025